Cargando…

Selection Strategy of Jaw Tracking in VMAT Planning for Lung SBRT

PURPOSE: This study aimed to investigate the dosimetric effect and delivery reliability of jaw tracking (JT) with increasing planning target volume (PTV) for lung stereotactic body radiation therapy (SBRT) plans. A threshold of PTV was proposed as a selection criterion between JT and fixed-jaw (FJ)...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Wuji, Shi, Yinghua, Li, Yu, Ge, Chao, Yang, Xu, Xia, Wenming, Chen, Kunzhi, Wang, Libo, Dong, Lihua, Wang, Huidong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860988/
https://www.ncbi.nlm.nih.gov/pubmed/35211411
http://dx.doi.org/10.3389/fonc.2022.820632
Descripción
Sumario:PURPOSE: This study aimed to investigate the dosimetric effect and delivery reliability of jaw tracking (JT) with increasing planning target volume (PTV) for lung stereotactic body radiation therapy (SBRT) plans. A threshold of PTV was proposed as a selection criterion between JT and fixed-jaw (FJ) techniques. METHODS: A total of 28 patients with early-stage non-small-cell lung cancer were retrospectively included. The PTVs ranged from 4.88 cc to 68.74 cc, prescribed with 48 Gy in four fractions. Three-partial-arc volumetric modulated arc therapy (VMAT) plans with FJ and with JT were created for each patient with the same optimization objectives. These two sets of plans were compared using metrics, including conformity index (CI), V(50%), R(50%), D(2cm), dose–volume parameters of organs at risk, and monitor units (MUs). The ratio of small subfields (<3 cm in either dimension), %SS, was acquired as a surrogate for the small-field uncertainty. Statistical analyses were performed to evaluate the correlation between the differences in these parameters and the PTV. RESULTS: The V(50%), R(50%), D(2cm), and V(20Gy), D(1,500cc), and D(1,000cc) of the lung showed a statistically significant improvement in JT plans as opposed to FJ plans, while the number of MU in JT plans was higher by an average of 1.9%. Between FJ and JT plans, the PTV was strongly correlated with the differences in V(50%), moderately correlated with those in V(20Gy) of the lung, and weakly correlated with those in D(2cm) and D(1,500cc) of the lung. By using JT, %SS was found to be negatively correlated with the PTV, and the PTV should be at least approximately 12.5 cc for an expected %SS <50%, which was 15 cc for a %SS <20% and 20 cc for a %SS <5%. CONCLUSIONS: Considering the dosimetric differences and small-field uncertainties, JT could be selected using a PTV threshold, such as 12.5, 15, or 20 cc, on the basis of the demand of delivery reliability for lung SBRT.