Cargando…

Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial

RATIONALE & OBJECTIVE: Arteriovenous fistula cannulation with the buttonhole technique is often preferred by patients but has been associated with an increased infection risk. Guidelines disagree on whether it should be abandoned, thus we assessed a technologically simple method to facilitate ge...

Descripción completa

Detalles Bibliográficos
Autores principales: Rønning, Marit I., Benschop, Willem P., Øvrehus, Marius A., Hultstrøm, Maria, Hallan, Stein I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8861953/
https://www.ncbi.nlm.nih.gov/pubmed/35243305
http://dx.doi.org/10.1016/j.xkme.2021.10.006
_version_ 1784654966931062784
author Rønning, Marit I.
Benschop, Willem P.
Øvrehus, Marius A.
Hultstrøm, Maria
Hallan, Stein I.
author_facet Rønning, Marit I.
Benschop, Willem P.
Øvrehus, Marius A.
Hultstrøm, Maria
Hallan, Stein I.
author_sort Rønning, Marit I.
collection PubMed
description RATIONALE & OBJECTIVE: Arteriovenous fistula cannulation with the buttonhole technique is often preferred by patients but has been associated with an increased infection risk. Guidelines disagree on whether it should be abandoned, thus we assessed a technologically simple method to facilitate gentler arteriovenous fistula cannulation with potentially less discomfort and damage to the epithelial lining of the buttonhole tract. STUDY DESIGN: 8-week, prospective, open-label, randomized controlled trial. SETTING & PARTICIPANTS: Patients with buttonhole tracts receiving hemodialysis at 7 dialysis centers in Norway were randomized to the intervention group (43 patients, 658 cannulations) or control group (40 patients, 611 cannulations). INTERVENTION: Direction and angle of the established buttonhole tract were marked on the forearm skin in the intervention group, whereas the control group had no structured cannulation information system. OUTCOMES: The primary outcome was successful cannulation, defined as correct placement of both blunt needles at the first attempt without needing to change needles, perform extra perforations, or reposition the needle. The secondary outcomes were patient-reported difficulty of cannulation (verbal rating scale: 1 = very easy, 6 = impossible) and intensity of pain (numeric rating scale: 0 = no pain, 10 = unbearable pain). RESULTS: After a 2-week run-in period, successful cannulation was achieved in 73.9% and 74.8% of the patients in the intervention and control groups, respectively (relative risk [RR], 0.99; 95% CI, 0.87-1.12; P = 0.85). However, the probability of a difficult arterial cannulation (verbal rating scale, 3-6) was significantly lower in the intervention group (RR, 0.69; 95% CI, 0.55-0.85; P = 0.001). There were no improvements for venous cannulations. Furthermore, the probability of a painful cannulation (numeric rating scale, 3-10) was lower in the intervention group (RR, 0.72; 95% CI, 0.51-1.02; P = 0.06). LIMITATIONS: Unable to evaluate hard end points such as infections and thrombosis owing to the small sample size. CONCLUSIONS: Marking direction and angle of cannulation did not improve cannulation success rates; however, patients more often reported an unproblematic procedure and less pain. FUNDING: None. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01536548).
format Online
Article
Text
id pubmed-8861953
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88619532022-03-02 Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial Rønning, Marit I. Benschop, Willem P. Øvrehus, Marius A. Hultstrøm, Maria Hallan, Stein I. Kidney Med Original Research RATIONALE & OBJECTIVE: Arteriovenous fistula cannulation with the buttonhole technique is often preferred by patients but has been associated with an increased infection risk. Guidelines disagree on whether it should be abandoned, thus we assessed a technologically simple method to facilitate gentler arteriovenous fistula cannulation with potentially less discomfort and damage to the epithelial lining of the buttonhole tract. STUDY DESIGN: 8-week, prospective, open-label, randomized controlled trial. SETTING & PARTICIPANTS: Patients with buttonhole tracts receiving hemodialysis at 7 dialysis centers in Norway were randomized to the intervention group (43 patients, 658 cannulations) or control group (40 patients, 611 cannulations). INTERVENTION: Direction and angle of the established buttonhole tract were marked on the forearm skin in the intervention group, whereas the control group had no structured cannulation information system. OUTCOMES: The primary outcome was successful cannulation, defined as correct placement of both blunt needles at the first attempt without needing to change needles, perform extra perforations, or reposition the needle. The secondary outcomes were patient-reported difficulty of cannulation (verbal rating scale: 1 = very easy, 6 = impossible) and intensity of pain (numeric rating scale: 0 = no pain, 10 = unbearable pain). RESULTS: After a 2-week run-in period, successful cannulation was achieved in 73.9% and 74.8% of the patients in the intervention and control groups, respectively (relative risk [RR], 0.99; 95% CI, 0.87-1.12; P = 0.85). However, the probability of a difficult arterial cannulation (verbal rating scale, 3-6) was significantly lower in the intervention group (RR, 0.69; 95% CI, 0.55-0.85; P = 0.001). There were no improvements for venous cannulations. Furthermore, the probability of a painful cannulation (numeric rating scale, 3-10) was lower in the intervention group (RR, 0.72; 95% CI, 0.51-1.02; P = 0.06). LIMITATIONS: Unable to evaluate hard end points such as infections and thrombosis owing to the small sample size. CONCLUSIONS: Marking direction and angle of cannulation did not improve cannulation success rates; however, patients more often reported an unproblematic procedure and less pain. FUNDING: None. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01536548). Elsevier 2021-12-01 /pmc/articles/PMC8861953/ /pubmed/35243305 http://dx.doi.org/10.1016/j.xkme.2021.10.006 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Research
Rønning, Marit I.
Benschop, Willem P.
Øvrehus, Marius A.
Hultstrøm, Maria
Hallan, Stein I.
Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial
title Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial
title_full Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial
title_fullStr Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial
title_full_unstemmed Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial
title_short Direction- and Angle-Assisted Buttonhole Cannulation of Arteriovenous Fistula in Hemodialysis Patients: A Multicenter Randomized Controlled Trial
title_sort direction- and angle-assisted buttonhole cannulation of arteriovenous fistula in hemodialysis patients: a multicenter randomized controlled trial
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8861953/
https://www.ncbi.nlm.nih.gov/pubmed/35243305
http://dx.doi.org/10.1016/j.xkme.2021.10.006
work_keys_str_mv AT rønningmariti directionandangleassistedbuttonholecannulationofarteriovenousfistulainhemodialysispatientsamulticenterrandomizedcontrolledtrial
AT benschopwillemp directionandangleassistedbuttonholecannulationofarteriovenousfistulainhemodialysispatientsamulticenterrandomizedcontrolledtrial
AT øvrehusmariusa directionandangleassistedbuttonholecannulationofarteriovenousfistulainhemodialysispatientsamulticenterrandomizedcontrolledtrial
AT hultstrømmaria directionandangleassistedbuttonholecannulationofarteriovenousfistulainhemodialysispatientsamulticenterrandomizedcontrolledtrial
AT hallansteini directionandangleassistedbuttonholecannulationofarteriovenousfistulainhemodialysispatientsamulticenterrandomizedcontrolledtrial