Cargando…

The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study

BACKGROUND: Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD....

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Jia Bin, Zuo, Rui, Zheng, Wen Jie, Li, Chang Qing, Zhang, Chao, Zhou, Yue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8862578/
https://www.ncbi.nlm.nih.gov/pubmed/35189892
http://dx.doi.org/10.1186/s12891-022-05101-6
_version_ 1784655079689682944
author Liu, Jia Bin
Zuo, Rui
Zheng, Wen Jie
Li, Chang Qing
Zhang, Chao
Zhou, Yue
author_facet Liu, Jia Bin
Zuo, Rui
Zheng, Wen Jie
Li, Chang Qing
Zhang, Chao
Zhou, Yue
author_sort Liu, Jia Bin
collection PubMed
description BACKGROUND: Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD. The purpose of this study was to establish an in vitro osteoporosis model and verify the accuracy and effectiveness of automated pedicle screw planning software based on CT values in this model. METHODS: Ten vertebrae (L1-L5) of normal adult pigs were randomly divided into decalcification and control groups. In the decalcification group, the vertebral bodies were decalcified with Ethylenediaminetetraacetic acid (EDTA) to construct an in vitro osteoporosis model. In the decalcification group, automatic planning (AP) and conventional manual planning (MP) were used to plan the pedicle screw trajectory on the left and right sides of the pedicle, respectively, and MP was used on both sides of the control group. CT values of trajectories obtained by the two methods were measured and compared. Then, 3D-printed guide plates were designed to assist pedicle screw placement. Finally, the pull-out force of the trajectory obtained by the two methods was measured. RESULTS: After decalcification, the BMD of the vertebra decreased from − 0.03 ± 1.03 to − 3.03 ± 0.29 (P < 0.05). In the decalcification group, the MP trajectory CT value was 2167.28 ± 65.62 Hu, the AP trajectory CT value was 2723.96 ± 165.83 Hu, and the MP trajectory CT value in the control group was 2242.94 ± 25.80 Hu (P < 0.05). In the decalcified vertebrae, the screw pull-out force of the MP group was 48.6% lower than that of the control group (P < 0.05). The pull-out force of the AP trajectory was 44.7% higher than that of the MP trajectory (P < 0.05) and reached 97.4% of the MP trajectory in the control group (P > 0.05). CONCLUSION: Automatic planning of the pedicle screw trajectory based on the CT value can obtain a higher screw pull-out force, which is a valuable new method of pedicle screw placement in osteoporotic vertebre. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-022-05101-6.
format Online
Article
Text
id pubmed-8862578
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88625782022-02-23 The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study Liu, Jia Bin Zuo, Rui Zheng, Wen Jie Li, Chang Qing Zhang, Chao Zhou, Yue BMC Musculoskelet Disord Research BACKGROUND: Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD. The purpose of this study was to establish an in vitro osteoporosis model and verify the accuracy and effectiveness of automated pedicle screw planning software based on CT values in this model. METHODS: Ten vertebrae (L1-L5) of normal adult pigs were randomly divided into decalcification and control groups. In the decalcification group, the vertebral bodies were decalcified with Ethylenediaminetetraacetic acid (EDTA) to construct an in vitro osteoporosis model. In the decalcification group, automatic planning (AP) and conventional manual planning (MP) were used to plan the pedicle screw trajectory on the left and right sides of the pedicle, respectively, and MP was used on both sides of the control group. CT values of trajectories obtained by the two methods were measured and compared. Then, 3D-printed guide plates were designed to assist pedicle screw placement. Finally, the pull-out force of the trajectory obtained by the two methods was measured. RESULTS: After decalcification, the BMD of the vertebra decreased from − 0.03 ± 1.03 to − 3.03 ± 0.29 (P < 0.05). In the decalcification group, the MP trajectory CT value was 2167.28 ± 65.62 Hu, the AP trajectory CT value was 2723.96 ± 165.83 Hu, and the MP trajectory CT value in the control group was 2242.94 ± 25.80 Hu (P < 0.05). In the decalcified vertebrae, the screw pull-out force of the MP group was 48.6% lower than that of the control group (P < 0.05). The pull-out force of the AP trajectory was 44.7% higher than that of the MP trajectory (P < 0.05) and reached 97.4% of the MP trajectory in the control group (P > 0.05). CONCLUSION: Automatic planning of the pedicle screw trajectory based on the CT value can obtain a higher screw pull-out force, which is a valuable new method of pedicle screw placement in osteoporotic vertebre. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-022-05101-6. BioMed Central 2022-02-21 /pmc/articles/PMC8862578/ /pubmed/35189892 http://dx.doi.org/10.1186/s12891-022-05101-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Liu, Jia Bin
Zuo, Rui
Zheng, Wen Jie
Li, Chang Qing
Zhang, Chao
Zhou, Yue
The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
title The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
title_full The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
title_fullStr The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
title_full_unstemmed The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
title_short The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
title_sort accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8862578/
https://www.ncbi.nlm.nih.gov/pubmed/35189892
http://dx.doi.org/10.1186/s12891-022-05101-6
work_keys_str_mv AT liujiabin theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zuorui theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zhengwenjie theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT lichangqing theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zhangchao theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zhouyue theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT liujiabin accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zuorui accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zhengwenjie accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT lichangqing accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zhangchao accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy
AT zhouyue accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy