Cargando…
The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study
BACKGROUND: Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD....
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8862578/ https://www.ncbi.nlm.nih.gov/pubmed/35189892 http://dx.doi.org/10.1186/s12891-022-05101-6 |
_version_ | 1784655079689682944 |
---|---|
author | Liu, Jia Bin Zuo, Rui Zheng, Wen Jie Li, Chang Qing Zhang, Chao Zhou, Yue |
author_facet | Liu, Jia Bin Zuo, Rui Zheng, Wen Jie Li, Chang Qing Zhang, Chao Zhou, Yue |
author_sort | Liu, Jia Bin |
collection | PubMed |
description | BACKGROUND: Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD. The purpose of this study was to establish an in vitro osteoporosis model and verify the accuracy and effectiveness of automated pedicle screw planning software based on CT values in this model. METHODS: Ten vertebrae (L1-L5) of normal adult pigs were randomly divided into decalcification and control groups. In the decalcification group, the vertebral bodies were decalcified with Ethylenediaminetetraacetic acid (EDTA) to construct an in vitro osteoporosis model. In the decalcification group, automatic planning (AP) and conventional manual planning (MP) were used to plan the pedicle screw trajectory on the left and right sides of the pedicle, respectively, and MP was used on both sides of the control group. CT values of trajectories obtained by the two methods were measured and compared. Then, 3D-printed guide plates were designed to assist pedicle screw placement. Finally, the pull-out force of the trajectory obtained by the two methods was measured. RESULTS: After decalcification, the BMD of the vertebra decreased from − 0.03 ± 1.03 to − 3.03 ± 0.29 (P < 0.05). In the decalcification group, the MP trajectory CT value was 2167.28 ± 65.62 Hu, the AP trajectory CT value was 2723.96 ± 165.83 Hu, and the MP trajectory CT value in the control group was 2242.94 ± 25.80 Hu (P < 0.05). In the decalcified vertebrae, the screw pull-out force of the MP group was 48.6% lower than that of the control group (P < 0.05). The pull-out force of the AP trajectory was 44.7% higher than that of the MP trajectory (P < 0.05) and reached 97.4% of the MP trajectory in the control group (P > 0.05). CONCLUSION: Automatic planning of the pedicle screw trajectory based on the CT value can obtain a higher screw pull-out force, which is a valuable new method of pedicle screw placement in osteoporotic vertebre. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-022-05101-6. |
format | Online Article Text |
id | pubmed-8862578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-88625782022-02-23 The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study Liu, Jia Bin Zuo, Rui Zheng, Wen Jie Li, Chang Qing Zhang, Chao Zhou, Yue BMC Musculoskelet Disord Research BACKGROUND: Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD. The purpose of this study was to establish an in vitro osteoporosis model and verify the accuracy and effectiveness of automated pedicle screw planning software based on CT values in this model. METHODS: Ten vertebrae (L1-L5) of normal adult pigs were randomly divided into decalcification and control groups. In the decalcification group, the vertebral bodies were decalcified with Ethylenediaminetetraacetic acid (EDTA) to construct an in vitro osteoporosis model. In the decalcification group, automatic planning (AP) and conventional manual planning (MP) were used to plan the pedicle screw trajectory on the left and right sides of the pedicle, respectively, and MP was used on both sides of the control group. CT values of trajectories obtained by the two methods were measured and compared. Then, 3D-printed guide plates were designed to assist pedicle screw placement. Finally, the pull-out force of the trajectory obtained by the two methods was measured. RESULTS: After decalcification, the BMD of the vertebra decreased from − 0.03 ± 1.03 to − 3.03 ± 0.29 (P < 0.05). In the decalcification group, the MP trajectory CT value was 2167.28 ± 65.62 Hu, the AP trajectory CT value was 2723.96 ± 165.83 Hu, and the MP trajectory CT value in the control group was 2242.94 ± 25.80 Hu (P < 0.05). In the decalcified vertebrae, the screw pull-out force of the MP group was 48.6% lower than that of the control group (P < 0.05). The pull-out force of the AP trajectory was 44.7% higher than that of the MP trajectory (P < 0.05) and reached 97.4% of the MP trajectory in the control group (P > 0.05). CONCLUSION: Automatic planning of the pedicle screw trajectory based on the CT value can obtain a higher screw pull-out force, which is a valuable new method of pedicle screw placement in osteoporotic vertebre. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-022-05101-6. BioMed Central 2022-02-21 /pmc/articles/PMC8862578/ /pubmed/35189892 http://dx.doi.org/10.1186/s12891-022-05101-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Liu, Jia Bin Zuo, Rui Zheng, Wen Jie Li, Chang Qing Zhang, Chao Zhou, Yue The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
title | The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
title_full | The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
title_fullStr | The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
title_full_unstemmed | The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
title_short | The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
title_sort | accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8862578/ https://www.ncbi.nlm.nih.gov/pubmed/35189892 http://dx.doi.org/10.1186/s12891-022-05101-6 |
work_keys_str_mv | AT liujiabin theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zuorui theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zhengwenjie theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT lichangqing theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zhangchao theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zhouyue theaccuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT liujiabin accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zuorui accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zhengwenjie accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT lichangqing accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zhangchao accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy AT zhouyue accuracyandeffectivenessofautomaticpediclescrewtrajectoryplanningbasedoncomputertomographyvaluesaninvitroosteoporosismodelstudy |