Cargando…
Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve
Bioprosthetic surgical aortic valve failure requiring reintervention is a frequent clinical problem with event rates up to 20% at 10 years after surgery. Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has become a valuable treatment option for these patients, although it requires carefu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8863485/ https://www.ncbi.nlm.nih.gov/pubmed/35250395 http://dx.doi.org/10.1155/2022/9899235 |
_version_ | 1784655251247202304 |
---|---|
author | Vanhaverbeke, Maarten De Backer, Ole Dubois, Christophe |
author_facet | Vanhaverbeke, Maarten De Backer, Ole Dubois, Christophe |
author_sort | Vanhaverbeke, Maarten |
collection | PubMed |
description | Bioprosthetic surgical aortic valve failure requiring reintervention is a frequent clinical problem with event rates up to 20% at 10 years after surgery. Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has become a valuable treatment option for these patients, although it requires careful procedural planning. We here describe and illustrate a stepwise approach to plan and perform ViV-TAVI and discuss preprocedural computerized tomography planning, transcatheter heart valve selection, and implantation techniques. Particular attention is paid to coronary artery protection and the possible need for bioprosthetic valve fracture since patients with small surgical aortic bioprostheses are at a risk of high residual gradients after ViV-TAVI. Considering updated clinical data on long-term outcomes following ViV-TAVI, this approach may become the default treatment strategy for patients with a failing surgical aortic bioprosthesis. |
format | Online Article Text |
id | pubmed-8863485 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-88634852022-03-04 Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve Vanhaverbeke, Maarten De Backer, Ole Dubois, Christophe J Interv Cardiol Review Article Bioprosthetic surgical aortic valve failure requiring reintervention is a frequent clinical problem with event rates up to 20% at 10 years after surgery. Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has become a valuable treatment option for these patients, although it requires careful procedural planning. We here describe and illustrate a stepwise approach to plan and perform ViV-TAVI and discuss preprocedural computerized tomography planning, transcatheter heart valve selection, and implantation techniques. Particular attention is paid to coronary artery protection and the possible need for bioprosthetic valve fracture since patients with small surgical aortic bioprostheses are at a risk of high residual gradients after ViV-TAVI. Considering updated clinical data on long-term outcomes following ViV-TAVI, this approach may become the default treatment strategy for patients with a failing surgical aortic bioprosthesis. Hindawi 2022-02-15 /pmc/articles/PMC8863485/ /pubmed/35250395 http://dx.doi.org/10.1155/2022/9899235 Text en Copyright © 2022 Maarten Vanhaverbeke et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Vanhaverbeke, Maarten De Backer, Ole Dubois, Christophe Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve |
title | Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve |
title_full | Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve |
title_fullStr | Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve |
title_full_unstemmed | Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve |
title_short | Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve |
title_sort | practical approach to transcatheter aortic valve implantation and bioprosthetic valve fracture in a failed bioprosthetic surgical valve |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8863485/ https://www.ncbi.nlm.nih.gov/pubmed/35250395 http://dx.doi.org/10.1155/2022/9899235 |
work_keys_str_mv | AT vanhaverbekemaarten practicalapproachtotranscatheteraorticvalveimplantationandbioprostheticvalvefractureinafailedbioprostheticsurgicalvalve AT debackerole practicalapproachtotranscatheteraorticvalveimplantationandbioprostheticvalvefractureinafailedbioprostheticsurgicalvalve AT duboischristophe practicalapproachtotranscatheteraorticvalveimplantationandbioprostheticvalvefractureinafailedbioprostheticsurgicalvalve |