Cargando…

Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning

PURPOSE: The current study aimed to compare contouring of glandular tissue only (gCTV) with the clinical target volume (CTV) as defined according to European Society for Radiotherapy and Oncology (ESTRO) guidelines (eCTV) and historically treated volumes (marked by wire and determined by palpation a...

Descripción completa

Detalles Bibliográficos
Autores principales: Duma, Marciana Nona, Kulms, Theresa, Knippen, Stefan, Teichmann, Tobias, Wittig, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8863698/
https://www.ncbi.nlm.nih.gov/pubmed/34477884
http://dx.doi.org/10.1007/s00066-021-01839-5
_version_ 1784655286375546880
author Duma, Marciana Nona
Kulms, Theresa
Knippen, Stefan
Teichmann, Tobias
Wittig, Andrea
author_facet Duma, Marciana Nona
Kulms, Theresa
Knippen, Stefan
Teichmann, Tobias
Wittig, Andrea
author_sort Duma, Marciana Nona
collection PubMed
description PURPOSE: The current study aimed to compare contouring of glandular tissue only (gCTV) with the clinical target volume (CTV) as defined according to European Society for Radiotherapy and Oncology (ESTRO) guidelines (eCTV) and historically treated volumes (marked by wire and determined by palpation and anatomic landmarks) in breast cancer radiotherapy. METHODS: A total of 56 consecutive breast cancer patients underwent treatment planning based solely on anatomic landmarks/wire markings (“wire based”). From these treatment plans, the 50% and 95% isodoses were transferred as structures and compared to the following CT-based volumes: eCTV; a Hounsfield unit (HU)-based automatic contouring of the gCTV; and standardized planning target volumes (PTVs) generated with 1‑cm safety margins (resulting in the ePTVs and gPTVs, respectively). RESULTS: The 95% isodose volume of the wire-based plan was larger than the eCTV by 352.39 ± 176.06 cm(3) but smaller than the ePTV by 157.58 ± 189.32 cm(3). The 95% isodose was larger than the gCTV by 921.20 ± 419.78 cm(3) and larger than the gPTV by 190.91 ± 233.49 cm(3). Patients with larger breasts had significantly less glandular tissue than those with small breasts. There was a trend toward a lower percentage of glandular tissue in older patients. CONCLUSION: Historical wire and anatomic landmarks-based treatment planning sufficiently covers the glandular tissue and the theoretical gPTV generated for the glandular tissue. Modern CT-based CTV and PTV definition according to ESTRO results in a larger treated volume than the historical wire-based techniques. HU-standardized glandular tissue contouring results in a significantly smaller CTV and might be an option for reducing the treatment volume and improving reproducibility of contouring between institutions.
format Online
Article
Text
id pubmed-8863698
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-88636982022-03-02 Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning Duma, Marciana Nona Kulms, Theresa Knippen, Stefan Teichmann, Tobias Wittig, Andrea Strahlenther Onkol Original Article PURPOSE: The current study aimed to compare contouring of glandular tissue only (gCTV) with the clinical target volume (CTV) as defined according to European Society for Radiotherapy and Oncology (ESTRO) guidelines (eCTV) and historically treated volumes (marked by wire and determined by palpation and anatomic landmarks) in breast cancer radiotherapy. METHODS: A total of 56 consecutive breast cancer patients underwent treatment planning based solely on anatomic landmarks/wire markings (“wire based”). From these treatment plans, the 50% and 95% isodoses were transferred as structures and compared to the following CT-based volumes: eCTV; a Hounsfield unit (HU)-based automatic contouring of the gCTV; and standardized planning target volumes (PTVs) generated with 1‑cm safety margins (resulting in the ePTVs and gPTVs, respectively). RESULTS: The 95% isodose volume of the wire-based plan was larger than the eCTV by 352.39 ± 176.06 cm(3) but smaller than the ePTV by 157.58 ± 189.32 cm(3). The 95% isodose was larger than the gCTV by 921.20 ± 419.78 cm(3) and larger than the gPTV by 190.91 ± 233.49 cm(3). Patients with larger breasts had significantly less glandular tissue than those with small breasts. There was a trend toward a lower percentage of glandular tissue in older patients. CONCLUSION: Historical wire and anatomic landmarks-based treatment planning sufficiently covers the glandular tissue and the theoretical gPTV generated for the glandular tissue. Modern CT-based CTV and PTV definition according to ESTRO results in a larger treated volume than the historical wire-based techniques. HU-standardized glandular tissue contouring results in a significantly smaller CTV and might be an option for reducing the treatment volume and improving reproducibility of contouring between institutions. Springer Berlin Heidelberg 2021-09-03 2022 /pmc/articles/PMC8863698/ /pubmed/34477884 http://dx.doi.org/10.1007/s00066-021-01839-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Duma, Marciana Nona
Kulms, Theresa
Knippen, Stefan
Teichmann, Tobias
Wittig, Andrea
Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning
title Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning
title_full Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning
title_fullStr Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning
title_full_unstemmed Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning
title_short Breast clinical target volume: HU-based glandular CTVs and ESTRO CTVs in modern and historical radiotherapy treatment planning
title_sort breast clinical target volume: hu-based glandular ctvs and estro ctvs in modern and historical radiotherapy treatment planning
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8863698/
https://www.ncbi.nlm.nih.gov/pubmed/34477884
http://dx.doi.org/10.1007/s00066-021-01839-5
work_keys_str_mv AT dumamarciananona breastclinicaltargetvolumehubasedglandularctvsandestroctvsinmodernandhistoricalradiotherapytreatmentplanning
AT kulmstheresa breastclinicaltargetvolumehubasedglandularctvsandestroctvsinmodernandhistoricalradiotherapytreatmentplanning
AT knippenstefan breastclinicaltargetvolumehubasedglandularctvsandestroctvsinmodernandhistoricalradiotherapytreatmentplanning
AT teichmanntobias breastclinicaltargetvolumehubasedglandularctvsandestroctvsinmodernandhistoricalradiotherapytreatmentplanning
AT wittigandrea breastclinicaltargetvolumehubasedglandularctvsandestroctvsinmodernandhistoricalradiotherapytreatmentplanning