Cargando…

Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery

To study the morphology of the posterior lens cortex and posterior capsules (PCs) in pediatric patients with posterior lens opacities using intraoperative optical coherence tomography (iOCT). SETTING: Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Prospective observat...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Wan, Lin, Zhuangling, Zhu, Qiaolin, Lin, Duoru, Chen, Hui, Wang, Jinghui, Chen, Jingjing, Wang, Qiwei, Wu, Xianghua, Lin, Zhuoling, Lin, Xiaoshan, Li, Xiaoyan, Li, Jing, Lin, Haotian, Chen, Weirong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8865201/
https://www.ncbi.nlm.nih.gov/pubmed/34338234
http://dx.doi.org/10.1097/j.jcrs.0000000000000763
_version_ 1784655603719733248
author Chen, Wan
Lin, Zhuangling
Zhu, Qiaolin
Lin, Duoru
Chen, Hui
Wang, Jinghui
Chen, Jingjing
Wang, Qiwei
Wu, Xianghua
Lin, Zhuoling
Lin, Xiaoshan
Li, Xiaoyan
Li, Jing
Lin, Haotian
Chen, Weirong
author_facet Chen, Wan
Lin, Zhuangling
Zhu, Qiaolin
Lin, Duoru
Chen, Hui
Wang, Jinghui
Chen, Jingjing
Wang, Qiwei
Wu, Xianghua
Lin, Zhuoling
Lin, Xiaoshan
Li, Xiaoyan
Li, Jing
Lin, Haotian
Chen, Weirong
author_sort Chen, Wan
collection PubMed
description To study the morphology of the posterior lens cortex and posterior capsules (PCs) in pediatric patients with posterior lens opacities using intraoperative optical coherence tomography (iOCT). SETTING: Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Prospective observational study. METHODS: Pediatric patients with posterior lens opacities were imaged using iOCT during cataract surgery. The morphology of the posterior lens cortex and PC, along with the common patterns to indicate PC integrity, was assessed. Moreover, PC rent during surgery was observed. RESULTS: A total of 62 eyes from 53 patients were included. The mean age of patients was 3.8 years. 4 morphological variants of posterior lens opacity were observed: type I (34/62 [54.8%]) with an intact PC; type II (20/62 [32.3%]) with an intact PC, which protruded into the anterior vitreous; type III (3/62 [4.8%]) with a deficient PC and an inability to delineate the PC; and type IV (5/62 [8.1%]) with dense opacity and an inability to characterize the posterior cortex and PC. Phacoemulsification could be performed in types I and II. In types III and IV, manual nucleus removal was performed instead of phacoemulsification. 3 cases (100%) of type III PC dehiscence developed during surgery, whereas no cases developed PC dehiscence of other types. CONCLUSIONS: The morphology of the PC and posterior lens cortex in pediatric posterior lens opacities could be categorized, and PC integrity could be assessed using iOCT, which was useful to guide surgical strategies and increase safety in pre-existing PC dehiscence in pediatric cataract surgery.
format Online
Article
Text
id pubmed-8865201
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer
record_format MEDLINE/PubMed
spelling pubmed-88652012022-02-24 Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery Chen, Wan Lin, Zhuangling Zhu, Qiaolin Lin, Duoru Chen, Hui Wang, Jinghui Chen, Jingjing Wang, Qiwei Wu, Xianghua Lin, Zhuoling Lin, Xiaoshan Li, Xiaoyan Li, Jing Lin, Haotian Chen, Weirong J Cataract Refract Surg Article To study the morphology of the posterior lens cortex and posterior capsules (PCs) in pediatric patients with posterior lens opacities using intraoperative optical coherence tomography (iOCT). SETTING: Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Prospective observational study. METHODS: Pediatric patients with posterior lens opacities were imaged using iOCT during cataract surgery. The morphology of the posterior lens cortex and PC, along with the common patterns to indicate PC integrity, was assessed. Moreover, PC rent during surgery was observed. RESULTS: A total of 62 eyes from 53 patients were included. The mean age of patients was 3.8 years. 4 morphological variants of posterior lens opacity were observed: type I (34/62 [54.8%]) with an intact PC; type II (20/62 [32.3%]) with an intact PC, which protruded into the anterior vitreous; type III (3/62 [4.8%]) with a deficient PC and an inability to delineate the PC; and type IV (5/62 [8.1%]) with dense opacity and an inability to characterize the posterior cortex and PC. Phacoemulsification could be performed in types I and II. In types III and IV, manual nucleus removal was performed instead of phacoemulsification. 3 cases (100%) of type III PC dehiscence developed during surgery, whereas no cases developed PC dehiscence of other types. CONCLUSIONS: The morphology of the PC and posterior lens cortex in pediatric posterior lens opacities could be categorized, and PC integrity could be assessed using iOCT, which was useful to guide surgical strategies and increase safety in pre-existing PC dehiscence in pediatric cataract surgery. Wolters Kluwer 2022-03 2021-07-29 /pmc/articles/PMC8865201/ /pubmed/34338234 http://dx.doi.org/10.1097/j.jcrs.0000000000000763 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of ASCRS and ESCRS https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Article
Chen, Wan
Lin, Zhuangling
Zhu, Qiaolin
Lin, Duoru
Chen, Hui
Wang, Jinghui
Chen, Jingjing
Wang, Qiwei
Wu, Xianghua
Lin, Zhuoling
Lin, Xiaoshan
Li, Xiaoyan
Li, Jing
Lin, Haotian
Chen, Weirong
Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery
title Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery
title_full Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery
title_fullStr Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery
title_full_unstemmed Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery
title_short Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery
title_sort intraoperative oct for the assessment of posterior capsular integrity in pediatric cataract surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8865201/
https://www.ncbi.nlm.nih.gov/pubmed/34338234
http://dx.doi.org/10.1097/j.jcrs.0000000000000763
work_keys_str_mv AT chenwan intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT linzhuangling intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT zhuqiaolin intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT linduoru intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT chenhui intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT wangjinghui intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT chenjingjing intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT wangqiwei intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT wuxianghua intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT linzhuoling intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT linxiaoshan intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT lixiaoyan intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT lijing intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT linhaotian intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery
AT chenweirong intraoperativeoctfortheassessmentofposteriorcapsularintegrityinpediatriccataractsurgery