Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial

To compare the effectiveness and safety of the TECNIS Symfony intraocular lens (IOL; ZXR00) with the TECNIS 1-piece monofocal IOL (ZCB00). SETTING: 15 sites in the United States. DESIGN: Prospective, randomized, patient-masked/evaluator-masked clinical trial. METHODS: Randomized participants receive...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Daniel H., Janakiraman, Devi Priya, Smith, Pamela J., Buteyn, Anne, Domingo, Joy, Jones, Jason J., Christie, William C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8865208/
https://www.ncbi.nlm.nih.gov/pubmed/34269326
http://dx.doi.org/10.1097/j.jcrs.0000000000000747
_version_ 1784655605194031104
author Chang, Daniel H.
Janakiraman, Devi Priya
Smith, Pamela J.
Buteyn, Anne
Domingo, Joy
Jones, Jason J.
Christie, William C.
author_facet Chang, Daniel H.
Janakiraman, Devi Priya
Smith, Pamela J.
Buteyn, Anne
Domingo, Joy
Jones, Jason J.
Christie, William C.
author_sort Chang, Daniel H.
collection PubMed
description To compare the effectiveness and safety of the TECNIS Symfony intraocular lens (IOL; ZXR00) with the TECNIS 1-piece monofocal IOL (ZCB00). SETTING: 15 sites in the United States. DESIGN: Prospective, randomized, patient-masked/evaluator-masked clinical trial. METHODS: Randomized participants received either the ZXR00 or ZCB00 IOL bilaterally. The 6-month postoperative outcomes included monocular and binocular distance, intermediate, and near visual acuity (VA), spherical equivalent refraction and refractive cylinder, spectacle wear, and visual symptoms. RESULTS: Overall, 299 patients were implanted with a study IOL (ZXR00 IOL, n = 148; ZCB00 IOL control, n = 151). At the 6-month follow-up, mean binocular uncorrected distance VA was comparable between ZXR00 and ZCB00 IOL recipients (P = .1011). The ZXR00 IOL group had significantly better mean binocular uncorrected intermediate VA and uncorrected near VA (both P < .0001) than the ZCB00 IOL group. The mean binocular distance-corrected intermediate VA and distance-corrected near VA were also better in the ZXR00 IOL group (both P < .0001). More ZXR00 IOL recipients reported wearing spectacles none of the time or a little of the time for overall vision at 6 months compared with the ZCB00 IOL group (85.0% vs 59.9%, P < .0001). In the ZXR00 IOL–implanted patients, low incidence rates of night glare (mild to moderate, 2.7%), halo (mild to moderate, 13.6%; severe, 2.7%), and starbursts (mild to moderate, 7.5%; severe, 1.4%) were reported. CONCLUSIONS: The TECNIS Symfony IOL provided comparable distance vision and improved uncorrected and distance-corrected intermediate and near vision, along with decreased spectacle wear and low incidence rates of dysphotopsia, compared with the TECNIS 1-piece monofocal IOL.
format Online
Article
Text
id pubmed-8865208
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer
record_format MEDLINE/PubMed
spelling pubmed-88652082022-02-24 Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial Chang, Daniel H. Janakiraman, Devi Priya Smith, Pamela J. Buteyn, Anne Domingo, Joy Jones, Jason J. Christie, William C. J Cataract Refract Surg Article To compare the effectiveness and safety of the TECNIS Symfony intraocular lens (IOL; ZXR00) with the TECNIS 1-piece monofocal IOL (ZCB00). SETTING: 15 sites in the United States. DESIGN: Prospective, randomized, patient-masked/evaluator-masked clinical trial. METHODS: Randomized participants received either the ZXR00 or ZCB00 IOL bilaterally. The 6-month postoperative outcomes included monocular and binocular distance, intermediate, and near visual acuity (VA), spherical equivalent refraction and refractive cylinder, spectacle wear, and visual symptoms. RESULTS: Overall, 299 patients were implanted with a study IOL (ZXR00 IOL, n = 148; ZCB00 IOL control, n = 151). At the 6-month follow-up, mean binocular uncorrected distance VA was comparable between ZXR00 and ZCB00 IOL recipients (P = .1011). The ZXR00 IOL group had significantly better mean binocular uncorrected intermediate VA and uncorrected near VA (both P < .0001) than the ZCB00 IOL group. The mean binocular distance-corrected intermediate VA and distance-corrected near VA were also better in the ZXR00 IOL group (both P < .0001). More ZXR00 IOL recipients reported wearing spectacles none of the time or a little of the time for overall vision at 6 months compared with the ZCB00 IOL group (85.0% vs 59.9%, P < .0001). In the ZXR00 IOL–implanted patients, low incidence rates of night glare (mild to moderate, 2.7%), halo (mild to moderate, 13.6%; severe, 2.7%), and starbursts (mild to moderate, 7.5%; severe, 1.4%) were reported. CONCLUSIONS: The TECNIS Symfony IOL provided comparable distance vision and improved uncorrected and distance-corrected intermediate and near vision, along with decreased spectacle wear and low incidence rates of dysphotopsia, compared with the TECNIS 1-piece monofocal IOL. Wolters Kluwer 2022-03 2021-07-13 /pmc/articles/PMC8865208/ /pubmed/34269326 http://dx.doi.org/10.1097/j.jcrs.0000000000000747 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of ASCRS and ESCRS https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Chang, Daniel H.
Janakiraman, Devi Priya
Smith, Pamela J.
Buteyn, Anne
Domingo, Joy
Jones, Jason J.
Christie, William C.
Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
title Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
title_full Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
title_fullStr Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
title_full_unstemmed Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
title_short Visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
title_sort visual outcomes and safety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8865208/
https://www.ncbi.nlm.nih.gov/pubmed/34269326
http://dx.doi.org/10.1097/j.jcrs.0000000000000747
work_keys_str_mv AT changdanielh visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial
AT janakiramandevipriya visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial
AT smithpamelaj visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial
AT buteynanne visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial
AT domingojoy visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial
AT jonesjasonj visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial
AT christiewilliamc visualoutcomesandsafetyofanextendeddepthoffocusintraocularlensresultsofapivotalclinicaltrial