Cargando…

Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids

The analysis of biological fluids is crucial for the diagnosis and monitoring of diseases causing effusions and helps in the diagnosis of infectious diseases. The gold standard method for cell count in biological fluids is the manual method using counting chambers. The microbiological routine proced...

Descripción completa

Detalles Bibliográficos
Autores principales: Dossou, N., Gaubert, I., Moriceau, C., Cornet, E., le Hello, S., Malandain, D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8865548/
https://www.ncbi.nlm.nih.gov/pubmed/35196801
http://dx.doi.org/10.1128/spectrum.01830-21
_version_ 1784655653547016192
author Dossou, N.
Gaubert, I.
Moriceau, C.
Cornet, E.
le Hello, S.
Malandain, D.
author_facet Dossou, N.
Gaubert, I.
Moriceau, C.
Cornet, E.
le Hello, S.
Malandain, D.
author_sort Dossou, N.
collection PubMed
description The analysis of biological fluids is crucial for the diagnosis and monitoring of diseases causing effusions and helps in the diagnosis of infectious diseases. The gold standard method for cell count in biological fluids is the manual method using counting chambers. The microbiological routine procedures consist of Direct Gram staining and culture on solid or liquid media. We evaluate the analytical performance of SYSMEX UF4000 (Sysmex, Kobe, Japan) and Sysmex XN10 (Sysmex, Kobe, Japan) in comparison with cytological and microbiological routine procedures. A total of 526 biological fluid samples were included in this study (42 ascitic, 31 pleural, 31 peritoneal, 125 cerebrospinal, 281 synovial, and 16 peritoneal dialysis fluids). All samples were analyzed by flow cytometry and subsequently processed following cytological and/or microbiological routine procedures. With regard to cell counts, UF4000 (Sysmex, Kobe, Japan) showed a performance that was at least equivalent to those of the reference methods and superior to those of XN10 (Sysmex, Kobe, Japan). Moreover, the bacterial count obtained with UF4000 (Sysmex, Kobe, Japan) was significantly higher among culture or Direct Gram stain positive samples. We established three optimal cutoff points to predict Direct Gram stain positive samples for peritoneal (465.0 bacteria/μL), synovial (1200.0 bacteria/μL), and cerebrospinal fluids (17.2 bacteria/μL) with maximum sensitivity and negative predictive values. Cell count and detection of bacteria by flow cytometry could be used upstream cytological and microbiological routine procedures to improve and accelerate the diagnosis of infection of biological fluid samples. IMPORTANCE The analysis of biological fluids is crucial for the diagnosis and monitoring of diseases causing effusions and helps in the diagnosis of infectious diseases. The possibility of carrying out cytological and microbiological analyses of biological fluid samples on the same automated machine would simplify the sample circuit (addressing the sample in a single laboratory, 24/7). It would also minimize the quantity of sample required. The performance of cytological and microbiological analysis by the flow cytometer UF 4000 (Sysmex, Kobe, Japan) has never been evaluated yet. This study has shown that bacterial count by flow cytometry using UF4000 (Sysmex, Kobe, Japan) could be used upstream of microbiological routine procedures to improve and to accelerate the diagnosis of infection of biological fluid samples.
format Online
Article
Text
id pubmed-8865548
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-88655482022-03-04 Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids Dossou, N. Gaubert, I. Moriceau, C. Cornet, E. le Hello, S. Malandain, D. Microbiol Spectr Research Article The analysis of biological fluids is crucial for the diagnosis and monitoring of diseases causing effusions and helps in the diagnosis of infectious diseases. The gold standard method for cell count in biological fluids is the manual method using counting chambers. The microbiological routine procedures consist of Direct Gram staining and culture on solid or liquid media. We evaluate the analytical performance of SYSMEX UF4000 (Sysmex, Kobe, Japan) and Sysmex XN10 (Sysmex, Kobe, Japan) in comparison with cytological and microbiological routine procedures. A total of 526 biological fluid samples were included in this study (42 ascitic, 31 pleural, 31 peritoneal, 125 cerebrospinal, 281 synovial, and 16 peritoneal dialysis fluids). All samples were analyzed by flow cytometry and subsequently processed following cytological and/or microbiological routine procedures. With regard to cell counts, UF4000 (Sysmex, Kobe, Japan) showed a performance that was at least equivalent to those of the reference methods and superior to those of XN10 (Sysmex, Kobe, Japan). Moreover, the bacterial count obtained with UF4000 (Sysmex, Kobe, Japan) was significantly higher among culture or Direct Gram stain positive samples. We established three optimal cutoff points to predict Direct Gram stain positive samples for peritoneal (465.0 bacteria/μL), synovial (1200.0 bacteria/μL), and cerebrospinal fluids (17.2 bacteria/μL) with maximum sensitivity and negative predictive values. Cell count and detection of bacteria by flow cytometry could be used upstream cytological and microbiological routine procedures to improve and accelerate the diagnosis of infection of biological fluid samples. IMPORTANCE The analysis of biological fluids is crucial for the diagnosis and monitoring of diseases causing effusions and helps in the diagnosis of infectious diseases. The possibility of carrying out cytological and microbiological analyses of biological fluid samples on the same automated machine would simplify the sample circuit (addressing the sample in a single laboratory, 24/7). It would also minimize the quantity of sample required. The performance of cytological and microbiological analysis by the flow cytometer UF 4000 (Sysmex, Kobe, Japan) has never been evaluated yet. This study has shown that bacterial count by flow cytometry using UF4000 (Sysmex, Kobe, Japan) could be used upstream of microbiological routine procedures to improve and to accelerate the diagnosis of infection of biological fluid samples. American Society for Microbiology 2022-02-23 /pmc/articles/PMC8865548/ /pubmed/35196801 http://dx.doi.org/10.1128/spectrum.01830-21 Text en Copyright © 2022 Dossou et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Dossou, N.
Gaubert, I.
Moriceau, C.
Cornet, E.
le Hello, S.
Malandain, D.
Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids
title Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids
title_full Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids
title_fullStr Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids
title_full_unstemmed Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids
title_short Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids
title_sort evaluation of flow cytometry for cell count and detection of bacteria in biological fluids
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8865548/
https://www.ncbi.nlm.nih.gov/pubmed/35196801
http://dx.doi.org/10.1128/spectrum.01830-21
work_keys_str_mv AT dossoun evaluationofflowcytometryforcellcountanddetectionofbacteriainbiologicalfluids
AT gauberti evaluationofflowcytometryforcellcountanddetectionofbacteriainbiologicalfluids
AT moriceauc evaluationofflowcytometryforcellcountanddetectionofbacteriainbiologicalfluids
AT cornete evaluationofflowcytometryforcellcountanddetectionofbacteriainbiologicalfluids
AT lehellos evaluationofflowcytometryforcellcountanddetectionofbacteriainbiologicalfluids
AT malandaind evaluationofflowcytometryforcellcountanddetectionofbacteriainbiologicalfluids