Cargando…
A prospective clinical evaluation of the diagnostic accuracy of the SARS-CoV-2 rapid antigen test using anterior nasal samples()
INTRODUCTION: The diagnostic accuracy of antigen testing of anterior nasal (AN) samples for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has not been evaluated in the Japanese population. This study assessed the diagnostic accuracy of the Roche SARS-CoV-2 rapid antigen...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8866084/ https://www.ncbi.nlm.nih.gov/pubmed/35256268 http://dx.doi.org/10.1016/j.jiac.2022.02.016 |
Sumario: | INTRODUCTION: The diagnostic accuracy of antigen testing of anterior nasal (AN) samples for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has not been evaluated in the Japanese population. This study assessed the diagnostic accuracy of the Roche SARS-CoV-2 rapid antigen test (rapid antigen test) using AN samples. METHODS: Two AN samples and one nasopharyngeal (NP) sample were collected from individuals undergoing screening for SARS-CoV-2 infection. The results of the rapid antigen test and the reverse-transcription polymerase chain reaction (RT-PCR) test using AN samples were compared to those of RT-PCR tests using NP samples. RESULTS: Samples were collected from 800 participants, 95 and 110 of whom tested positive for SARS-CoV-2 on RT-PCR tests of AN and NP samples, respectively. The overall sensitivity/specificity of the AN rapid antigen test and AN RT-PCR were 72.7%/100% and 86.4%/100%, respectively. In symptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 84.7% and 94.9%, respectively. In asymptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 58.8% and 76.5%, respectively. The sensitivity of the AN rapid antigen test was over 80% in cases with cycle threshold (Ct) values < 25; it significantly decreased with an increase in the Ct values (p < 0.001). CONCLUSION: The rapid antigen test with AN samples had a favorable sensitivity, especially in symptomatic cases or in cases with Ct values < 25. It gave no false-positive results. Compared with AN-RT PCR, the AN rapid antigen test had a modestly lower sensitivity in asymptomatic cases. |
---|