Cargando…
Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study
BACKGROUND: Passive paramagnetic markers on magnetic resonance imaging (MRI)-compatible endovascular devices induce susceptibility artifacts, enabling MRI-visibility and real-time MRI-guidance. Optimised visibility is crucial for automatic detection and device tracking but depends on MRI technical p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8866618/ https://www.ncbi.nlm.nih.gov/pubmed/35199259 http://dx.doi.org/10.1186/s41747-022-00262-4 |
_version_ | 1784655871934988288 |
---|---|
author | Nijsink, Han Overduin, Christiaan G. Brand, Patrick De Jong, Sytse F. Borm, Paul J. A. Warlé, Michiel C. Fütterer, Jurgen J. |
author_facet | Nijsink, Han Overduin, Christiaan G. Brand, Patrick De Jong, Sytse F. Borm, Paul J. A. Warlé, Michiel C. Fütterer, Jurgen J. |
author_sort | Nijsink, Han |
collection | PubMed |
description | BACKGROUND: Passive paramagnetic markers on magnetic resonance imaging (MRI)-compatible endovascular devices induce susceptibility artifacts, enabling MRI-visibility and real-time MRI-guidance. Optimised visibility is crucial for automatic detection and device tracking but depends on MRI technical parameters and marker characteristics. We assessed marker visibility and automatic detection robustness for varying MRI parameters and marker characteristics in a pulsatile flow phantom. METHODS: Guidewires with varying iron(II,III) oxide nanoparticle (IONP) concentration markers were imaged using gradient-echo (GRE) and balanced steady-state free precession (bSSFP) sequences at 3 T. Furthermore, echo time (TE), slice thickness (ST) and phase encoding direction (PED) were varied. Artifact width was measured and contrast-to-noise ratios were calculated. Marker visibility and image quality were scored by two MRI interventional radiologists. Additionally, a deep learning model for automatic marker detection was trained and the effects of the parameters on detection performance were evaluated. Two-tailed Wilcoxon signed-rank tests were used (significance level, p < 0.05). RESULTS: Medan artifact width (IQR) was larger in bSSFP compared to GRE images (12.7 mm (11.0–15.2) versus 8.4 mm (6.5–11.0)) (p < 0.001) and showed a positive relation with TE and IONP concentration. Switching PED and doubling ST had limited effect on artifact width. Image quality assessment scores were higher for GRE compared to bSSFP images. The deep learning model automatically detected the markers. However, the model performance was reduced after adjusting PED, TE, and IONP concentration. CONCLUSION: Marker visibility was sufficient and a large range of artifact sizes was generated by adjusting TE and IONP concentration. Deep learning-based marker detection was feasible but performance decreased for altered MR parameters. These factors should be considered to optimise device visibility and ensure reliable automatic marker detectability in MRI-guided endovascular interventions. |
format | Online Article Text |
id | pubmed-8866618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-88666182022-03-02 Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study Nijsink, Han Overduin, Christiaan G. Brand, Patrick De Jong, Sytse F. Borm, Paul J. A. Warlé, Michiel C. Fütterer, Jurgen J. Eur Radiol Exp Original Article BACKGROUND: Passive paramagnetic markers on magnetic resonance imaging (MRI)-compatible endovascular devices induce susceptibility artifacts, enabling MRI-visibility and real-time MRI-guidance. Optimised visibility is crucial for automatic detection and device tracking but depends on MRI technical parameters and marker characteristics. We assessed marker visibility and automatic detection robustness for varying MRI parameters and marker characteristics in a pulsatile flow phantom. METHODS: Guidewires with varying iron(II,III) oxide nanoparticle (IONP) concentration markers were imaged using gradient-echo (GRE) and balanced steady-state free precession (bSSFP) sequences at 3 T. Furthermore, echo time (TE), slice thickness (ST) and phase encoding direction (PED) were varied. Artifact width was measured and contrast-to-noise ratios were calculated. Marker visibility and image quality were scored by two MRI interventional radiologists. Additionally, a deep learning model for automatic marker detection was trained and the effects of the parameters on detection performance were evaluated. Two-tailed Wilcoxon signed-rank tests were used (significance level, p < 0.05). RESULTS: Medan artifact width (IQR) was larger in bSSFP compared to GRE images (12.7 mm (11.0–15.2) versus 8.4 mm (6.5–11.0)) (p < 0.001) and showed a positive relation with TE and IONP concentration. Switching PED and doubling ST had limited effect on artifact width. Image quality assessment scores were higher for GRE compared to bSSFP images. The deep learning model automatically detected the markers. However, the model performance was reduced after adjusting PED, TE, and IONP concentration. CONCLUSION: Marker visibility was sufficient and a large range of artifact sizes was generated by adjusting TE and IONP concentration. Deep learning-based marker detection was feasible but performance decreased for altered MR parameters. These factors should be considered to optimise device visibility and ensure reliable automatic marker detectability in MRI-guided endovascular interventions. Springer International Publishing 2022-02-24 /pmc/articles/PMC8866618/ /pubmed/35199259 http://dx.doi.org/10.1186/s41747-022-00262-4 Text en © The Author(s) under exclusive licence to European Society of Radiology 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Nijsink, Han Overduin, Christiaan G. Brand, Patrick De Jong, Sytse F. Borm, Paul J. A. Warlé, Michiel C. Fütterer, Jurgen J. Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study |
title | Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study |
title_full | Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study |
title_fullStr | Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study |
title_full_unstemmed | Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study |
title_short | Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study |
title_sort | optimised passive marker device visibility and automatic marker detection for 3-t mri-guided endovascular interventions: a pulsatile flow phantom study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8866618/ https://www.ncbi.nlm.nih.gov/pubmed/35199259 http://dx.doi.org/10.1186/s41747-022-00262-4 |
work_keys_str_mv | AT nijsinkhan optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy AT overduinchristiaang optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy AT brandpatrick optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy AT dejongsytsef optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy AT bormpaulja optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy AT warlemichielc optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy AT futtererjurgenj optimisedpassivemarkerdevicevisibilityandautomaticmarkerdetectionfor3tmriguidedendovascularinterventionsapulsatileflowphantomstudy |