Cargando…

Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review

Next‐generation sequencing (NGS) has developed rapidly in the last decade and is emerging as a promising diagnostic tool for periprosthetic joint infection (PJI). However, its diagnostic value for PJI is still uncertain. This systematic review aimed to explore the diagnostic value of NGS for PJI and...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Yuchen, Zhao, Dacheng, Wang, Shenghong, Yi, Qiong, Xia, Yayi, Geng, Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8867422/
https://www.ncbi.nlm.nih.gov/pubmed/34935279
http://dx.doi.org/10.1111/os.13191
_version_ 1784656049406476288
author Tang, Yuchen
Zhao, Dacheng
Wang, Shenghong
Yi, Qiong
Xia, Yayi
Geng, Bin
author_facet Tang, Yuchen
Zhao, Dacheng
Wang, Shenghong
Yi, Qiong
Xia, Yayi
Geng, Bin
author_sort Tang, Yuchen
collection PubMed
description Next‐generation sequencing (NGS) has developed rapidly in the last decade and is emerging as a promising diagnostic tool for periprosthetic joint infection (PJI). However, its diagnostic value for PJI is still uncertain. This systematic review aimed to explore the diagnostic value of NGS for PJI and verify its accuracy for culture‐negative PJI patients. We conducted this systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta‐Analysis (PRISMA) guidelines. Medline, Embase, and Cochrane Library were searched to identify diagnostic technique studies evaluating the accuracy of NGS in the diagnosis of PJI. The diagnostic sensitivity, specificity, and positive and negative predictive values were estimated for each article. The detection rate of NGS for culture‐negative PJI patients or PJI patients with antibiotic administration history was also calculated. Of the 87 identified citations, nine studies met the inclusion criteria. The diagnostic sensitivities and specificities of NGS ranged from 63% to 96% and 73% to 100%, respectively. The positive and negative predictive values ranged from 71% to 100% and 74% to 95%, respectively. The detection rate of NGS for culture‐negative PJI patients in six studies was higher than 50% (range from 82% to 100%), while in three studies it was lower than 50% (range from 9% to 31%). Also, the detection rate of NGS for PJIs with antibiotic administration history ranged from 74.05% to 92.31%. In conclusion, this systematic review suggests that NGS may have the potential to be a new tool for the diagnosis of PJI and should be considered to be added to the portfolio of diagnostic procedures. Furthermore, NGS showed a favorable diagnostic accuracy for culture‐negative PJI patients or PJI patients with antibiotic administration history. However, due to the small sample sizes of studies and substantial heterogeneity among the included studies, more research is needed to confirm or disprove these findings.
format Online
Article
Text
id pubmed-8867422
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-88674222022-02-27 Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review Tang, Yuchen Zhao, Dacheng Wang, Shenghong Yi, Qiong Xia, Yayi Geng, Bin Orthop Surg Review Articles Next‐generation sequencing (NGS) has developed rapidly in the last decade and is emerging as a promising diagnostic tool for periprosthetic joint infection (PJI). However, its diagnostic value for PJI is still uncertain. This systematic review aimed to explore the diagnostic value of NGS for PJI and verify its accuracy for culture‐negative PJI patients. We conducted this systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta‐Analysis (PRISMA) guidelines. Medline, Embase, and Cochrane Library were searched to identify diagnostic technique studies evaluating the accuracy of NGS in the diagnosis of PJI. The diagnostic sensitivity, specificity, and positive and negative predictive values were estimated for each article. The detection rate of NGS for culture‐negative PJI patients or PJI patients with antibiotic administration history was also calculated. Of the 87 identified citations, nine studies met the inclusion criteria. The diagnostic sensitivities and specificities of NGS ranged from 63% to 96% and 73% to 100%, respectively. The positive and negative predictive values ranged from 71% to 100% and 74% to 95%, respectively. The detection rate of NGS for culture‐negative PJI patients in six studies was higher than 50% (range from 82% to 100%), while in three studies it was lower than 50% (range from 9% to 31%). Also, the detection rate of NGS for PJIs with antibiotic administration history ranged from 74.05% to 92.31%. In conclusion, this systematic review suggests that NGS may have the potential to be a new tool for the diagnosis of PJI and should be considered to be added to the portfolio of diagnostic procedures. Furthermore, NGS showed a favorable diagnostic accuracy for culture‐negative PJI patients or PJI patients with antibiotic administration history. However, due to the small sample sizes of studies and substantial heterogeneity among the included studies, more research is needed to confirm or disprove these findings. John Wiley & Sons Australia, Ltd 2021-12-21 /pmc/articles/PMC8867422/ /pubmed/34935279 http://dx.doi.org/10.1111/os.13191 Text en © 2021 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Review Articles
Tang, Yuchen
Zhao, Dacheng
Wang, Shenghong
Yi, Qiong
Xia, Yayi
Geng, Bin
Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review
title Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review
title_full Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review
title_fullStr Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review
title_full_unstemmed Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review
title_short Diagnostic Value of Next‐Generation Sequencing in Periprosthetic Joint Infection: A Systematic Review
title_sort diagnostic value of next‐generation sequencing in periprosthetic joint infection: a systematic review
topic Review Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8867422/
https://www.ncbi.nlm.nih.gov/pubmed/34935279
http://dx.doi.org/10.1111/os.13191
work_keys_str_mv AT tangyuchen diagnosticvalueofnextgenerationsequencinginperiprostheticjointinfectionasystematicreview
AT zhaodacheng diagnosticvalueofnextgenerationsequencinginperiprostheticjointinfectionasystematicreview
AT wangshenghong diagnosticvalueofnextgenerationsequencinginperiprostheticjointinfectionasystematicreview
AT yiqiong diagnosticvalueofnextgenerationsequencinginperiprostheticjointinfectionasystematicreview
AT xiayayi diagnosticvalueofnextgenerationsequencinginperiprostheticjointinfectionasystematicreview
AT gengbin diagnosticvalueofnextgenerationsequencinginperiprostheticjointinfectionasystematicreview