Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry

[Image: see text] In this study, an analytical method has been developed that, for the first time, allows simultaneous determination of vitamin D(2) and vitamin D(3) along with their hydroxylated and esterified forms. A group of 12 vitamin D analogues including vitamin D(2) and vitamin D(3), seven h...

Descripción completa

Detalles Bibliográficos
Autores principales: Socas-Rodríguez, Bárbara, Pilařová, Veronika, Sandahl, Margareta, Holm, Cecilia, Turner, Charlotta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8867463/
https://www.ncbi.nlm.nih.gov/pubmed/35138814
http://dx.doi.org/10.1021/acs.analchem.1c04016
_version_ 1784656059128872960
author Socas-Rodríguez, Bárbara
Pilařová, Veronika
Sandahl, Margareta
Holm, Cecilia
Turner, Charlotta
author_facet Socas-Rodríguez, Bárbara
Pilařová, Veronika
Sandahl, Margareta
Holm, Cecilia
Turner, Charlotta
author_sort Socas-Rodríguez, Bárbara
collection PubMed
description [Image: see text] In this study, an analytical method has been developed that, for the first time, allows simultaneous determination of vitamin D(2) and vitamin D(3) along with their hydroxylated and esterified forms. A group of 12 vitamin D analogues including vitamin D(2) and vitamin D(3), seven hydroxylated metabolites, and three ester forms were separated in a single 8.0 min run using ultrahigh-performance supercritical fluid chromatography coupled with triple quadrupole tandem mass spectrometry. Electrospray ionization and atmospheric pressure chemical ionization were investigated as ion sources, of which the latter showed a higher ionization efficiency. Chromatographic conditions were thoroughly evaluated by a step-by-step method, whereas an experimental design was applied for the optimization of the ionization parameters. Calibration and repeatability studies were carried out to validate the instrumental methodology showing determination coefficients higher than 0.9992 and good intra- and interday precision with relative standard deviations for areas and retention times lower than 10 and 2.1%, respectively, for all target analytes. Limits of quantification were below 3.03 μg/L for all compounds. The methodology was then validated and applied for the evaluation of human plasma samples in order to demonstrate its applicability to the analysis of vitamin D analogues in biological samples. Samples of five individuals were analyzed. Results show that linoleate-D(3), vitamin D(2), vitamin D(3), 25-hydroxyvitamin D(2), 24,25-dihydroxyvitamin D(3), and 1,25-dihydroxyvitamin D(3) could be detected in most samples, while the two latter also were quantified in all analyzed samples.
format Online
Article
Text
id pubmed-8867463
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-88674632022-02-24 Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry Socas-Rodríguez, Bárbara Pilařová, Veronika Sandahl, Margareta Holm, Cecilia Turner, Charlotta Anal Chem [Image: see text] In this study, an analytical method has been developed that, for the first time, allows simultaneous determination of vitamin D(2) and vitamin D(3) along with their hydroxylated and esterified forms. A group of 12 vitamin D analogues including vitamin D(2) and vitamin D(3), seven hydroxylated metabolites, and three ester forms were separated in a single 8.0 min run using ultrahigh-performance supercritical fluid chromatography coupled with triple quadrupole tandem mass spectrometry. Electrospray ionization and atmospheric pressure chemical ionization were investigated as ion sources, of which the latter showed a higher ionization efficiency. Chromatographic conditions were thoroughly evaluated by a step-by-step method, whereas an experimental design was applied for the optimization of the ionization parameters. Calibration and repeatability studies were carried out to validate the instrumental methodology showing determination coefficients higher than 0.9992 and good intra- and interday precision with relative standard deviations for areas and retention times lower than 10 and 2.1%, respectively, for all target analytes. Limits of quantification were below 3.03 μg/L for all compounds. The methodology was then validated and applied for the evaluation of human plasma samples in order to demonstrate its applicability to the analysis of vitamin D analogues in biological samples. Samples of five individuals were analyzed. Results show that linoleate-D(3), vitamin D(2), vitamin D(3), 25-hydroxyvitamin D(2), 24,25-dihydroxyvitamin D(3), and 1,25-dihydroxyvitamin D(3) could be detected in most samples, while the two latter also were quantified in all analyzed samples. American Chemical Society 2022-02-09 2022-02-22 /pmc/articles/PMC8867463/ /pubmed/35138814 http://dx.doi.org/10.1021/acs.analchem.1c04016 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Socas-Rodríguez, Bárbara
Pilařová, Veronika
Sandahl, Margareta
Holm, Cecilia
Turner, Charlotta
Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry
title Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry
title_full Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry
title_fullStr Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry
title_full_unstemmed Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry
title_short Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography–Tandem Mass Spectrometry
title_sort simultaneous determination of vitamin d and its hydroxylated and esterified metabolites by ultrahigh-performance supercritical fluid chromatography–tandem mass spectrometry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8867463/
https://www.ncbi.nlm.nih.gov/pubmed/35138814
http://dx.doi.org/10.1021/acs.analchem.1c04016
work_keys_str_mv AT socasrodriguezbarbara simultaneousdeterminationofvitamindanditshydroxylatedandesterifiedmetabolitesbyultrahighperformancesupercriticalfluidchromatographytandemmassspectrometry
AT pilarovaveronika simultaneousdeterminationofvitamindanditshydroxylatedandesterifiedmetabolitesbyultrahighperformancesupercriticalfluidchromatographytandemmassspectrometry
AT sandahlmargareta simultaneousdeterminationofvitamindanditshydroxylatedandesterifiedmetabolitesbyultrahighperformancesupercriticalfluidchromatographytandemmassspectrometry
AT holmcecilia simultaneousdeterminationofvitamindanditshydroxylatedandesterifiedmetabolitesbyultrahighperformancesupercriticalfluidchromatographytandemmassspectrometry
AT turnercharlotta simultaneousdeterminationofvitamindanditshydroxylatedandesterifiedmetabolitesbyultrahighperformancesupercriticalfluidchromatographytandemmassspectrometry