Cargando…
A Clinical Evaluation of Minimally Invasive Ponto Surgery With a Modified Drill System for Inserting Bone-Anchored Hearing Implants
To compare 6-months outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the linear incision technique with soft tissue preservation (LIT-TP), and original MIPS (o-MIPS) for inserting bone-anchored hearing implants (BAHIs). STUDY DESIGN: Exploratory pilot study with one test gr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8867490/ https://www.ncbi.nlm.nih.gov/pubmed/34191785 http://dx.doi.org/10.1097/MAO.0000000000003195 |
Sumario: | To compare 6-months outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the linear incision technique with soft tissue preservation (LIT-TP), and original MIPS (o-MIPS) for inserting bone-anchored hearing implants (BAHIs). STUDY DESIGN: Exploratory pilot study with one test group and two historical control groups. SETTING: Tertiary referral center. PATIENTS: In the test group, 24 patients (25 implants) were prospectively included. Each control group comprised 25 patients (25 implants) who participated in previously conducted clinical trials. INTERVENTIONS: The test group received a BAHI using m-MIPS. The two control groups underwent surgery using the LIT-TP and o-MIPS, respectively. MAIN OUTCOME MEASURES: Implant survival, implant stability, and surgery-related variables were compared between the test and control groups. Soft tissue status, skin sensibility, and subjective numbness were compared between m-MIPS and LIT-TP only. RESULTS: Implant survival was comparable between m-MIPS and LIT-TP, whereas implant stability measurements were slightly lower for m-MIPS. M-MIPS resulted in comparable adverse skin reactions and skin sensibility, significantly reduced surgical time and slightly improved subjective numbness, compared with LIT-TP. Between m-MIPS and o-MIPS, no statistically significant differences in implant survival, implant stability and surgical time were observed. CONCLUSIONS: A trend toward lower implant loss rates after m-MIPS was observed, when compared with o-MIPS. M-MIPS seems to be a good alternative to LIT-TP for inserting BAHIs, since most clinical outcomes were either comparable or slightly better for m-MIPS. Upon deciding on which technique to use, larger studies on implant survival should be performed. Furthermore, other aspects such as costs, training aspects and surgical experience should be evaluated. |
---|