Cargando…

Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes

SIMPLE SUMMARY: Virtual clinical trials in X-ray breast imaging may permit substantial reduction of the costs, times, and exposure risk to patient of clinical trials. Monte Carlo simulation techniques are increasingly adopted for VCT in breast imaging and dosimetry studies. This work aims to compare...

Descripción completa

Detalles Bibliográficos
Autores principales: Mettivier, Giovanni, Sarno, Antonio, Lai, Youfang, Golosio, Bruno, Fanti, Viviana, Italiano, Maria Elena, Jia, Xun, Russo, Paolo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8870739/
https://www.ncbi.nlm.nih.gov/pubmed/35205775
http://dx.doi.org/10.3390/cancers14041027
_version_ 1784656830187700224
author Mettivier, Giovanni
Sarno, Antonio
Lai, Youfang
Golosio, Bruno
Fanti, Viviana
Italiano, Maria Elena
Jia, Xun
Russo, Paolo
author_facet Mettivier, Giovanni
Sarno, Antonio
Lai, Youfang
Golosio, Bruno
Fanti, Viviana
Italiano, Maria Elena
Jia, Xun
Russo, Paolo
author_sort Mettivier, Giovanni
collection PubMed
description SIMPLE SUMMARY: Virtual clinical trials in X-ray breast imaging may permit substantial reduction of the costs, times, and exposure risk to patient of clinical trials. Monte Carlo simulation techniques are increasingly adopted for VCT in breast imaging and dosimetry studies. This work aims to compare three different platforms for breast VCT studies, to develop real-time virtual DM, DBT and BCT examinations, where the in-silico image acquisition process takes a computational time comparable to that typical of a corresponding real clinical examination. ABSTRACT: Computational reproductions of medical imaging tests, a form of virtual clinical trials (VCTs), are increasingly being used, particularly in breast imaging research. The accuracy of the computational platform that is used for the imaging and dosimetry simulation processes is a fundamental requirement. Moreover, for practical usage, the imaging simulation computation time should be compatible with the clinical workflow. We compared three different platforms for in-silico X-ray 3D breast imaging: the Agata (University & INFN Napoli) that was based on the Geant4 toolkit and running on a CPU-based server architecture; the XRMC Monte Carlo (University of Cagliari) that was based on the use of variance reduction techniques, running on a CPU hardware; and the Monte Carlo code gCTD (University of Texas Southwestern Medical Center) running on a single GPU platform with CUDA environment. The tests simulated the irradiation of cylindrical objects as well as anthropomorphic breast phantoms and produced 2D and 3D images and 3D maps of absorbed dose. All the codes showed compatible results in terms of simulated dose maps and imaging values within a maximum discrepancy of 3%. The GPU-based code produced a reduction of the computation time up to factor 10(4), and so permits real-time VCT studies for X-ray breast imaging.
format Online
Article
Text
id pubmed-8870739
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88707392022-02-25 Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes Mettivier, Giovanni Sarno, Antonio Lai, Youfang Golosio, Bruno Fanti, Viviana Italiano, Maria Elena Jia, Xun Russo, Paolo Cancers (Basel) Article SIMPLE SUMMARY: Virtual clinical trials in X-ray breast imaging may permit substantial reduction of the costs, times, and exposure risk to patient of clinical trials. Monte Carlo simulation techniques are increasingly adopted for VCT in breast imaging and dosimetry studies. This work aims to compare three different platforms for breast VCT studies, to develop real-time virtual DM, DBT and BCT examinations, where the in-silico image acquisition process takes a computational time comparable to that typical of a corresponding real clinical examination. ABSTRACT: Computational reproductions of medical imaging tests, a form of virtual clinical trials (VCTs), are increasingly being used, particularly in breast imaging research. The accuracy of the computational platform that is used for the imaging and dosimetry simulation processes is a fundamental requirement. Moreover, for practical usage, the imaging simulation computation time should be compatible with the clinical workflow. We compared three different platforms for in-silico X-ray 3D breast imaging: the Agata (University & INFN Napoli) that was based on the Geant4 toolkit and running on a CPU-based server architecture; the XRMC Monte Carlo (University of Cagliari) that was based on the use of variance reduction techniques, running on a CPU hardware; and the Monte Carlo code gCTD (University of Texas Southwestern Medical Center) running on a single GPU platform with CUDA environment. The tests simulated the irradiation of cylindrical objects as well as anthropomorphic breast phantoms and produced 2D and 3D images and 3D maps of absorbed dose. All the codes showed compatible results in terms of simulated dose maps and imaging values within a maximum discrepancy of 3%. The GPU-based code produced a reduction of the computation time up to factor 10(4), and so permits real-time VCT studies for X-ray breast imaging. MDPI 2022-02-17 /pmc/articles/PMC8870739/ /pubmed/35205775 http://dx.doi.org/10.3390/cancers14041027 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mettivier, Giovanni
Sarno, Antonio
Lai, Youfang
Golosio, Bruno
Fanti, Viviana
Italiano, Maria Elena
Jia, Xun
Russo, Paolo
Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes
title Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes
title_full Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes
title_fullStr Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes
title_full_unstemmed Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes
title_short Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes
title_sort virtual clinical trials in 2d and 3d x-ray breast imaging and dosimetry: comparison of cpu-based and gpu-based monte carlo codes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8870739/
https://www.ncbi.nlm.nih.gov/pubmed/35205775
http://dx.doi.org/10.3390/cancers14041027
work_keys_str_mv AT mettiviergiovanni virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT sarnoantonio virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT laiyoufang virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT golosiobruno virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT fantiviviana virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT italianomariaelena virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT jiaxun virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes
AT russopaolo virtualclinicaltrialsin2dand3dxraybreastimaginganddosimetrycomparisonofcpubasedandgpubasedmontecarlocodes