Cargando…

Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery

The purpose of this study was to investigate the viability of the proposed method in preventing the loss of metallic components including the clip and coil in cerebral computed tomography angiography (CTA). Forty patients undergoing surgery for aneurysms carried metallic materials. The proposed meth...

Descripción completa

Detalles Bibliográficos
Autores principales: Shim, Jina, Lee, Su Hwan, Lee, Youngjin, Kim, Kyu Bom, Kim, Kyuseok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8871085/
https://www.ncbi.nlm.nih.gov/pubmed/35204429
http://dx.doi.org/10.3390/diagnostics12020338
_version_ 1784656912123428864
author Shim, Jina
Lee, Su Hwan
Lee, Youngjin
Kim, Kyu Bom
Kim, Kyuseok
author_facet Shim, Jina
Lee, Su Hwan
Lee, Youngjin
Kim, Kyu Bom
Kim, Kyuseok
author_sort Shim, Jina
collection PubMed
description The purpose of this study was to investigate the viability of the proposed method in preventing the loss of metallic components including the clip and coil in cerebral computed tomography angiography (CTA). Forty patients undergoing surgery for aneurysms carried metallic materials. The proposed method is based on conventional bone subtraction CTA (BS-CTA) system. Briefly, the position of metal components was determined using the threshold value and a region of interest (ROI). An appropriate threshold was used to separate the background from the target materials based on the Otsu method. A three-dimensional (3D) rendering was performed from the proposed BS-CTA data carrying the extracted target information. The accuracy of clip and coil region measured using the dice similarity coefficient (DSC) and bidirectional Hausdorff distance (HD) is reported. The metallic components of the proposed BS-CTA were significantly visualized in various patient cases. Quantitative evaluation using the proposed method is based on the mean DSC of 0.93 with a standard deviation (SD) of ±0.05 (e.g., maximum value = 0.99, minimum value = 0.75, 95% confidence interval (CI) = 0.91 to 0.95, and all p < 0.05). The mean HD was 1.50 voxels with an SD of ± 0.58 (e.g., maximum value = 5.95, minimum value = 0.12, 95% CI = 1.10 to 1.90, and all p < 0.05). The proposed method demonstrates effective segmentation of the metallic component and application to the existing conventional BS-CTA system.
format Online
Article
Text
id pubmed-8871085
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88710852022-02-25 Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery Shim, Jina Lee, Su Hwan Lee, Youngjin Kim, Kyu Bom Kim, Kyuseok Diagnostics (Basel) Article The purpose of this study was to investigate the viability of the proposed method in preventing the loss of metallic components including the clip and coil in cerebral computed tomography angiography (CTA). Forty patients undergoing surgery for aneurysms carried metallic materials. The proposed method is based on conventional bone subtraction CTA (BS-CTA) system. Briefly, the position of metal components was determined using the threshold value and a region of interest (ROI). An appropriate threshold was used to separate the background from the target materials based on the Otsu method. A three-dimensional (3D) rendering was performed from the proposed BS-CTA data carrying the extracted target information. The accuracy of clip and coil region measured using the dice similarity coefficient (DSC) and bidirectional Hausdorff distance (HD) is reported. The metallic components of the proposed BS-CTA were significantly visualized in various patient cases. Quantitative evaluation using the proposed method is based on the mean DSC of 0.93 with a standard deviation (SD) of ±0.05 (e.g., maximum value = 0.99, minimum value = 0.75, 95% confidence interval (CI) = 0.91 to 0.95, and all p < 0.05). The mean HD was 1.50 voxels with an SD of ± 0.58 (e.g., maximum value = 5.95, minimum value = 0.12, 95% CI = 1.10 to 1.90, and all p < 0.05). The proposed method demonstrates effective segmentation of the metallic component and application to the existing conventional BS-CTA system. MDPI 2022-01-28 /pmc/articles/PMC8871085/ /pubmed/35204429 http://dx.doi.org/10.3390/diagnostics12020338 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shim, Jina
Lee, Su Hwan
Lee, Youngjin
Kim, Kyu Bom
Kim, Kyuseok
Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery
title Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery
title_full Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery
title_fullStr Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery
title_full_unstemmed Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery
title_short Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery
title_sort metallic component preserving algorithm based on the cerebral computed tomography angiography in aneurysm surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8871085/
https://www.ncbi.nlm.nih.gov/pubmed/35204429
http://dx.doi.org/10.3390/diagnostics12020338
work_keys_str_mv AT shimjina metalliccomponentpreservingalgorithmbasedonthecerebralcomputedtomographyangiographyinaneurysmsurgery
AT leesuhwan metalliccomponentpreservingalgorithmbasedonthecerebralcomputedtomographyangiographyinaneurysmsurgery
AT leeyoungjin metalliccomponentpreservingalgorithmbasedonthecerebralcomputedtomographyangiographyinaneurysmsurgery
AT kimkyubom metalliccomponentpreservingalgorithmbasedonthecerebralcomputedtomographyangiographyinaneurysmsurgery
AT kimkyuseok metalliccomponentpreservingalgorithmbasedonthecerebralcomputedtomographyangiographyinaneurysmsurgery