Cargando…
EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
The aim of this study was to evaluate the usefulness of superb microvascular imaging (SMI) versus contrast-enhanced ultrasound (CEUS) and compared to computed tomography angiography (CTA) as a reference standard, for detection of type II endoleak during follow-up of endovascular abdominal aortic ane...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8871225/ https://www.ncbi.nlm.nih.gov/pubmed/35204615 http://dx.doi.org/10.3390/diagnostics12020526 |
_version_ | 1784656946092048384 |
---|---|
author | Curti, Marco Piacentino, Filippo Fontana, Federico Ossola, Christian Coppola, Andrea Marra, Paolo Basile, Antonio Ierardi, Anna Maria Carrafiello, Gianpaolo Carcano, Giulio Tozzi, Matteo Piffaretti, Gabriele Venturini, Massimo |
author_facet | Curti, Marco Piacentino, Filippo Fontana, Federico Ossola, Christian Coppola, Andrea Marra, Paolo Basile, Antonio Ierardi, Anna Maria Carrafiello, Gianpaolo Carcano, Giulio Tozzi, Matteo Piffaretti, Gabriele Venturini, Massimo |
author_sort | Curti, Marco |
collection | PubMed |
description | The aim of this study was to evaluate the usefulness of superb microvascular imaging (SMI) versus contrast-enhanced ultrasound (CEUS) and compared to computed tomography angiography (CTA) as a reference standard, for detection of type II endoleak during follow-up of endovascular abdominal aortic aneurysm repair (EVAR). Between April 2017 and September 2020, 122 patients underwent post-EVAR follow-up with CTA at 3 months and with ultrasound SMI and CEUS at 4 months from the EVAR procedure. Aneurysmal sac diameter and graft patency were evaluated; endoleaks were assessed and classified. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy were calculated both for SMI and CEUS and compared to CTA. Furthermore, the percentage of agreement and Cohen’s Kappa coefficient were calculated. CTA revealed 54 type II endoleaks. Ultrasound SMI and CEUS presented the same sensitivity (91.5%), specificity (100%), positive (100%), and negative (92.8%) predictive and accuracy (95.9%) value for detecting type II endoleak. The same percentage of agreement of 94.9% was found between SMI/CEUS, and CTA with a Cohen’s Kappa coefficient of 0.89. The diagnostic accuracy of SMI is comparable with CEUS in the identification of type II endoleaks after EVAR. Since SMI is less invasive, less expensive, and less time-consuming, this method may be considered to be a potential tool for monitoring patients after EVAR implantation. |
format | Online Article Text |
id | pubmed-8871225 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88712252022-02-25 EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak Curti, Marco Piacentino, Filippo Fontana, Federico Ossola, Christian Coppola, Andrea Marra, Paolo Basile, Antonio Ierardi, Anna Maria Carrafiello, Gianpaolo Carcano, Giulio Tozzi, Matteo Piffaretti, Gabriele Venturini, Massimo Diagnostics (Basel) Article The aim of this study was to evaluate the usefulness of superb microvascular imaging (SMI) versus contrast-enhanced ultrasound (CEUS) and compared to computed tomography angiography (CTA) as a reference standard, for detection of type II endoleak during follow-up of endovascular abdominal aortic aneurysm repair (EVAR). Between April 2017 and September 2020, 122 patients underwent post-EVAR follow-up with CTA at 3 months and with ultrasound SMI and CEUS at 4 months from the EVAR procedure. Aneurysmal sac diameter and graft patency were evaluated; endoleaks were assessed and classified. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy were calculated both for SMI and CEUS and compared to CTA. Furthermore, the percentage of agreement and Cohen’s Kappa coefficient were calculated. CTA revealed 54 type II endoleaks. Ultrasound SMI and CEUS presented the same sensitivity (91.5%), specificity (100%), positive (100%), and negative (92.8%) predictive and accuracy (95.9%) value for detecting type II endoleak. The same percentage of agreement of 94.9% was found between SMI/CEUS, and CTA with a Cohen’s Kappa coefficient of 0.89. The diagnostic accuracy of SMI is comparable with CEUS in the identification of type II endoleaks after EVAR. Since SMI is less invasive, less expensive, and less time-consuming, this method may be considered to be a potential tool for monitoring patients after EVAR implantation. MDPI 2022-02-18 /pmc/articles/PMC8871225/ /pubmed/35204615 http://dx.doi.org/10.3390/diagnostics12020526 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Curti, Marco Piacentino, Filippo Fontana, Federico Ossola, Christian Coppola, Andrea Marra, Paolo Basile, Antonio Ierardi, Anna Maria Carrafiello, Gianpaolo Carcano, Giulio Tozzi, Matteo Piffaretti, Gabriele Venturini, Massimo EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak |
title | EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak |
title_full | EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak |
title_fullStr | EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak |
title_full_unstemmed | EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak |
title_short | EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak |
title_sort | evar follow-up with ultrasound superb microvascular imaging (smi) compared to ceus and ct angiography for detection of type ii endoleak |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8871225/ https://www.ncbi.nlm.nih.gov/pubmed/35204615 http://dx.doi.org/10.3390/diagnostics12020526 |
work_keys_str_mv | AT curtimarco evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT piacentinofilippo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT fontanafederico evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT ossolachristian evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT coppolaandrea evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT marrapaolo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT basileantonio evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT ierardiannamaria evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT carrafiellogianpaolo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT carcanogiulio evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT tozzimatteo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT piffarettigabriele evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak AT venturinimassimo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak |