EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak

The aim of this study was to evaluate the usefulness of superb microvascular imaging (SMI) versus contrast-enhanced ultrasound (CEUS) and compared to computed tomography angiography (CTA) as a reference standard, for detection of type II endoleak during follow-up of endovascular abdominal aortic ane...

Descripción completa

Detalles Bibliográficos
Autores principales: Curti, Marco, Piacentino, Filippo, Fontana, Federico, Ossola, Christian, Coppola, Andrea, Marra, Paolo, Basile, Antonio, Ierardi, Anna Maria, Carrafiello, Gianpaolo, Carcano, Giulio, Tozzi, Matteo, Piffaretti, Gabriele, Venturini, Massimo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8871225/
https://www.ncbi.nlm.nih.gov/pubmed/35204615
http://dx.doi.org/10.3390/diagnostics12020526
_version_ 1784656946092048384
author Curti, Marco
Piacentino, Filippo
Fontana, Federico
Ossola, Christian
Coppola, Andrea
Marra, Paolo
Basile, Antonio
Ierardi, Anna Maria
Carrafiello, Gianpaolo
Carcano, Giulio
Tozzi, Matteo
Piffaretti, Gabriele
Venturini, Massimo
author_facet Curti, Marco
Piacentino, Filippo
Fontana, Federico
Ossola, Christian
Coppola, Andrea
Marra, Paolo
Basile, Antonio
Ierardi, Anna Maria
Carrafiello, Gianpaolo
Carcano, Giulio
Tozzi, Matteo
Piffaretti, Gabriele
Venturini, Massimo
author_sort Curti, Marco
collection PubMed
description The aim of this study was to evaluate the usefulness of superb microvascular imaging (SMI) versus contrast-enhanced ultrasound (CEUS) and compared to computed tomography angiography (CTA) as a reference standard, for detection of type II endoleak during follow-up of endovascular abdominal aortic aneurysm repair (EVAR). Between April 2017 and September 2020, 122 patients underwent post-EVAR follow-up with CTA at 3 months and with ultrasound SMI and CEUS at 4 months from the EVAR procedure. Aneurysmal sac diameter and graft patency were evaluated; endoleaks were assessed and classified. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy were calculated both for SMI and CEUS and compared to CTA. Furthermore, the percentage of agreement and Cohen’s Kappa coefficient were calculated. CTA revealed 54 type II endoleaks. Ultrasound SMI and CEUS presented the same sensitivity (91.5%), specificity (100%), positive (100%), and negative (92.8%) predictive and accuracy (95.9%) value for detecting type II endoleak. The same percentage of agreement of 94.9% was found between SMI/CEUS, and CTA with a Cohen’s Kappa coefficient of 0.89. The diagnostic accuracy of SMI is comparable with CEUS in the identification of type II endoleaks after EVAR. Since SMI is less invasive, less expensive, and less time-consuming, this method may be considered to be a potential tool for monitoring patients after EVAR implantation.
format Online
Article
Text
id pubmed-8871225
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88712252022-02-25 EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak Curti, Marco Piacentino, Filippo Fontana, Federico Ossola, Christian Coppola, Andrea Marra, Paolo Basile, Antonio Ierardi, Anna Maria Carrafiello, Gianpaolo Carcano, Giulio Tozzi, Matteo Piffaretti, Gabriele Venturini, Massimo Diagnostics (Basel) Article The aim of this study was to evaluate the usefulness of superb microvascular imaging (SMI) versus contrast-enhanced ultrasound (CEUS) and compared to computed tomography angiography (CTA) as a reference standard, for detection of type II endoleak during follow-up of endovascular abdominal aortic aneurysm repair (EVAR). Between April 2017 and September 2020, 122 patients underwent post-EVAR follow-up with CTA at 3 months and with ultrasound SMI and CEUS at 4 months from the EVAR procedure. Aneurysmal sac diameter and graft patency were evaluated; endoleaks were assessed and classified. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy were calculated both for SMI and CEUS and compared to CTA. Furthermore, the percentage of agreement and Cohen’s Kappa coefficient were calculated. CTA revealed 54 type II endoleaks. Ultrasound SMI and CEUS presented the same sensitivity (91.5%), specificity (100%), positive (100%), and negative (92.8%) predictive and accuracy (95.9%) value for detecting type II endoleak. The same percentage of agreement of 94.9% was found between SMI/CEUS, and CTA with a Cohen’s Kappa coefficient of 0.89. The diagnostic accuracy of SMI is comparable with CEUS in the identification of type II endoleaks after EVAR. Since SMI is less invasive, less expensive, and less time-consuming, this method may be considered to be a potential tool for monitoring patients after EVAR implantation. MDPI 2022-02-18 /pmc/articles/PMC8871225/ /pubmed/35204615 http://dx.doi.org/10.3390/diagnostics12020526 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Curti, Marco
Piacentino, Filippo
Fontana, Federico
Ossola, Christian
Coppola, Andrea
Marra, Paolo
Basile, Antonio
Ierardi, Anna Maria
Carrafiello, Gianpaolo
Carcano, Giulio
Tozzi, Matteo
Piffaretti, Gabriele
Venturini, Massimo
EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
title EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
title_full EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
title_fullStr EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
title_full_unstemmed EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
title_short EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak
title_sort evar follow-up with ultrasound superb microvascular imaging (smi) compared to ceus and ct angiography for detection of type ii endoleak
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8871225/
https://www.ncbi.nlm.nih.gov/pubmed/35204615
http://dx.doi.org/10.3390/diagnostics12020526
work_keys_str_mv AT curtimarco evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT piacentinofilippo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT fontanafederico evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT ossolachristian evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT coppolaandrea evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT marrapaolo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT basileantonio evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT ierardiannamaria evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT carrafiellogianpaolo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT carcanogiulio evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT tozzimatteo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT piffarettigabriele evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak
AT venturinimassimo evarfollowupwithultrasoundsuperbmicrovascularimagingsmicomparedtoceusandctangiographyfordetectionoftypeiiendoleak