Cargando…
Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration
The performance of continuous radon monitors (CRMs) is usually evaluated under controlled conditions in a radon chamber during calibrations or intercomparison exercises. The impact of thoron on CRMs response is rarely evaluated; in case the evaluation is performed, it is carried out in a controlled...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8872230/ https://www.ncbi.nlm.nih.gov/pubmed/35206618 http://dx.doi.org/10.3390/ijerph19042423 |
_version_ | 1784657188787060736 |
---|---|
author | Di Carlo, Christian Ampollini, Marco Antignani, Sara Caprio, Mario Carpentieri, Carmela Bochicchio, Francesco |
author_facet | Di Carlo, Christian Ampollini, Marco Antignani, Sara Caprio, Mario Carpentieri, Carmela Bochicchio, Francesco |
author_sort | Di Carlo, Christian |
collection | PubMed |
description | The performance of continuous radon monitors (CRMs) is usually evaluated under controlled conditions in a radon chamber during calibrations or intercomparison exercises. The impact of thoron on CRMs response is rarely evaluated; in case the evaluation is performed, it is carried out in a controlled atmosphere with relatively constant, homogeneous, and generally high thoron concentrations and very low radon levels. In a real indoor environment, both radon and thoron concentrations are extremely variable, so the thoron interference evaluations reported in the literature are generally not applicable to CRMs used to measure radon concentration indoors. For this reason, an experimental study was carried out with four different CRMs in an indoor environment (an office room) where medium-to-high concentrations of both radon and thoron were expected. Thoron concentration has been separately evaluated throughout two different active monitors. Three CRMs resulted in overestimations of radon concentration by about 10% due to thoron interference, whereas such interference results were negligible for the fourth CRM. However, the thoron interference can also be used to assess thoron concentration by using CRM not specifically designed to do so. Based on the results of this study, an indirect method to assess thoron concentration is indeed proposed, relying on the combination of two identical monitors (one placed right close to the wall and the other one far enough from there). |
format | Online Article Text |
id | pubmed-8872230 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88722302022-02-25 Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration Di Carlo, Christian Ampollini, Marco Antignani, Sara Caprio, Mario Carpentieri, Carmela Bochicchio, Francesco Int J Environ Res Public Health Article The performance of continuous radon monitors (CRMs) is usually evaluated under controlled conditions in a radon chamber during calibrations or intercomparison exercises. The impact of thoron on CRMs response is rarely evaluated; in case the evaluation is performed, it is carried out in a controlled atmosphere with relatively constant, homogeneous, and generally high thoron concentrations and very low radon levels. In a real indoor environment, both radon and thoron concentrations are extremely variable, so the thoron interference evaluations reported in the literature are generally not applicable to CRMs used to measure radon concentration indoors. For this reason, an experimental study was carried out with four different CRMs in an indoor environment (an office room) where medium-to-high concentrations of both radon and thoron were expected. Thoron concentration has been separately evaluated throughout two different active monitors. Three CRMs resulted in overestimations of radon concentration by about 10% due to thoron interference, whereas such interference results were negligible for the fourth CRM. However, the thoron interference can also be used to assess thoron concentration by using CRM not specifically designed to do so. Based on the results of this study, an indirect method to assess thoron concentration is indeed proposed, relying on the combination of two identical monitors (one placed right close to the wall and the other one far enough from there). MDPI 2022-02-19 /pmc/articles/PMC8872230/ /pubmed/35206618 http://dx.doi.org/10.3390/ijerph19042423 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Di Carlo, Christian Ampollini, Marco Antignani, Sara Caprio, Mario Carpentieri, Carmela Bochicchio, Francesco Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration |
title | Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration |
title_full | Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration |
title_fullStr | Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration |
title_full_unstemmed | Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration |
title_short | Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration |
title_sort | thoron interference on performance of continuous radon monitors: an experimental study on four devices and a proposal of an indirect method to estimate thoron concentration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8872230/ https://www.ncbi.nlm.nih.gov/pubmed/35206618 http://dx.doi.org/10.3390/ijerph19042423 |
work_keys_str_mv | AT dicarlochristian thoroninterferenceonperformanceofcontinuousradonmonitorsanexperimentalstudyonfourdevicesandaproposalofanindirectmethodtoestimatethoronconcentration AT ampollinimarco thoroninterferenceonperformanceofcontinuousradonmonitorsanexperimentalstudyonfourdevicesandaproposalofanindirectmethodtoestimatethoronconcentration AT antignanisara thoroninterferenceonperformanceofcontinuousradonmonitorsanexperimentalstudyonfourdevicesandaproposalofanindirectmethodtoestimatethoronconcentration AT capriomario thoroninterferenceonperformanceofcontinuousradonmonitorsanexperimentalstudyonfourdevicesandaproposalofanindirectmethodtoestimatethoronconcentration AT carpentiericarmela thoroninterferenceonperformanceofcontinuousradonmonitorsanexperimentalstudyonfourdevicesandaproposalofanindirectmethodtoestimatethoronconcentration AT bochicchiofrancesco thoroninterferenceonperformanceofcontinuousradonmonitorsanexperimentalstudyonfourdevicesandaproposalofanindirectmethodtoestimatethoronconcentration |