Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?

An important factor affecting the accuracy of Young's modulus calculation in Atomic Force Microscopy (AFM) indentation experiments is the determination of the dimensions of the indenter. This procedure is usually performed using AFM calibration gratings or Scanning Electron Microscopy (SEM) ima...

Descripción completa

Detalles Bibliográficos
Autores principales: Kontomaris, S. V., Stylianou, A., Malamou, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8872683/
https://www.ncbi.nlm.nih.gov/pubmed/35265251
http://dx.doi.org/10.1155/2022/6463063
_version_ 1784657299166461952
author Kontomaris, S. V.
Stylianou, A.
Malamou, A.
author_facet Kontomaris, S. V.
Stylianou, A.
Malamou, A.
author_sort Kontomaris, S. V.
collection PubMed
description An important factor affecting the accuracy of Young's modulus calculation in Atomic Force Microscopy (AFM) indentation experiments is the determination of the dimensions of the indenter. This procedure is usually performed using AFM calibration gratings or Scanning Electron Microscopy (SEM) imaging. However, the aforementioned procedure is frequently omitted because it requires additional equipment. In this paper, a new approach is presented that focused on the calibration of spherical indenters without the need of special equipment but instead using force indentation data on soft samples. Firstly, the question whether it is mathematically possible to simultaneously calculate the indenter's radius and the Young's modulus of the tested sample (under the restriction that the sample presents a linear elastic response) using the same force indentation data is discussed. Using a simple mathematical approach, it was proved that the aforementioned procedure is theoretically valid. In addition, to test this method in real indentation experiments agarose gels were used. Multiple measurements on different agarose gels showed that the calibration of a spherical indenter is possible and can be accurately performed. Thus, the indenter's radius and the soft sample's Young's modulus can be determined using the same force indentation data. It is also important to note that the provided accuracy is similar to the accuracy obtained when using AFM calibration gratings. The major advantage of this paper is that it provides a method for the simultaneous determination of the indenter's radius and the sample's Young's modulus without requiring any additional equipment.
format Online
Article
Text
id pubmed-8872683
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-88726832022-03-08 Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples? Kontomaris, S. V. Stylianou, A. Malamou, A. Scanning Research Article An important factor affecting the accuracy of Young's modulus calculation in Atomic Force Microscopy (AFM) indentation experiments is the determination of the dimensions of the indenter. This procedure is usually performed using AFM calibration gratings or Scanning Electron Microscopy (SEM) imaging. However, the aforementioned procedure is frequently omitted because it requires additional equipment. In this paper, a new approach is presented that focused on the calibration of spherical indenters without the need of special equipment but instead using force indentation data on soft samples. Firstly, the question whether it is mathematically possible to simultaneously calculate the indenter's radius and the Young's modulus of the tested sample (under the restriction that the sample presents a linear elastic response) using the same force indentation data is discussed. Using a simple mathematical approach, it was proved that the aforementioned procedure is theoretically valid. In addition, to test this method in real indentation experiments agarose gels were used. Multiple measurements on different agarose gels showed that the calibration of a spherical indenter is possible and can be accurately performed. Thus, the indenter's radius and the soft sample's Young's modulus can be determined using the same force indentation data. It is also important to note that the provided accuracy is similar to the accuracy obtained when using AFM calibration gratings. The major advantage of this paper is that it provides a method for the simultaneous determination of the indenter's radius and the sample's Young's modulus without requiring any additional equipment. Hindawi 2022-02-17 /pmc/articles/PMC8872683/ /pubmed/35265251 http://dx.doi.org/10.1155/2022/6463063 Text en Copyright © 2022 S. V. Kontomaris et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kontomaris, S. V.
Stylianou, A.
Malamou, A.
Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?
title Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?
title_full Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?
title_fullStr Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?
title_full_unstemmed Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?
title_short Is It Possible to Directly Determine the Radius of a Spherical Indenter Using Force Indentation Data on Soft Samples?
title_sort is it possible to directly determine the radius of a spherical indenter using force indentation data on soft samples?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8872683/
https://www.ncbi.nlm.nih.gov/pubmed/35265251
http://dx.doi.org/10.1155/2022/6463063
work_keys_str_mv AT kontomarissv isitpossibletodirectlydeterminetheradiusofasphericalindenterusingforceindentationdataonsoftsamples
AT stylianoua isitpossibletodirectlydeterminetheradiusofasphericalindenterusingforceindentationdataonsoftsamples
AT malamoua isitpossibletodirectlydeterminetheradiusofasphericalindenterusingforceindentationdataonsoftsamples