Cargando…
Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment
Hydro-thermal technology had been used to improve the anti-corrosion and anti-wear performance of anodizing coating on the surface of aluminium alloys. The micromorphology of the coating has been studied by SEM and results proved the coating had a compact structure. The element in the substrate had...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8876477/ https://www.ncbi.nlm.nih.gov/pubmed/35207985 http://dx.doi.org/10.3390/ma15041447 |
_version_ | 1784658184136294400 |
---|---|
author | Liu, Debo Zhang, Baofeng Song, Wei |
author_facet | Liu, Debo Zhang, Baofeng Song, Wei |
author_sort | Liu, Debo |
collection | PubMed |
description | Hydro-thermal technology had been used to improve the anti-corrosion and anti-wear performance of anodizing coating on the surface of aluminium alloys. The micromorphology of the coating has been studied by SEM and results proved the coating had a compact structure. The element in the substrate had been characterized by EDS and results proved Fe had redissolved to the Al substrate. The crystalline structure of the coating had been studied by XRD and results proved the anodic coating could be transformed into η-, p- and γ-alumina. The electrochemical properties had been researched using an electrochemical workstation; results proved after the coating had been treated by hydro-thermal technology, its anti-corrosion properties could be improved. At the hydro-thermal temperature of 400 ℃, its open circuit voltage and impedance reached −0.46 V and 160 kΩ × cm(2), respectively. The hardness of the coating had to be measured with an HVS-100 micro-hardness tester, with results proving that, after the hydro-thermal treatment, the hardness of the coating increased to 150 HV. The friction coefficient of the coating had been studied using a ball-on-disk tester, and the results proved it decreased to 0.46. The MMW-2 scratch tester had been used to measure the adhesion between the coating and substrate; results proved the coating had better adhesion with the substrate. The thermal conductivity of the coating had been studied by a heat conduction coefficient measurement device; results proved that it reached 11.2 W/m × K at a hydro-thermal temperature of 400 ℃, far higher than that of organic coating. |
format | Online Article Text |
id | pubmed-8876477 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88764772022-02-26 Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment Liu, Debo Zhang, Baofeng Song, Wei Materials (Basel) Article Hydro-thermal technology had been used to improve the anti-corrosion and anti-wear performance of anodizing coating on the surface of aluminium alloys. The micromorphology of the coating has been studied by SEM and results proved the coating had a compact structure. The element in the substrate had been characterized by EDS and results proved Fe had redissolved to the Al substrate. The crystalline structure of the coating had been studied by XRD and results proved the anodic coating could be transformed into η-, p- and γ-alumina. The electrochemical properties had been researched using an electrochemical workstation; results proved after the coating had been treated by hydro-thermal technology, its anti-corrosion properties could be improved. At the hydro-thermal temperature of 400 ℃, its open circuit voltage and impedance reached −0.46 V and 160 kΩ × cm(2), respectively. The hardness of the coating had to be measured with an HVS-100 micro-hardness tester, with results proving that, after the hydro-thermal treatment, the hardness of the coating increased to 150 HV. The friction coefficient of the coating had been studied using a ball-on-disk tester, and the results proved it decreased to 0.46. The MMW-2 scratch tester had been used to measure the adhesion between the coating and substrate; results proved the coating had better adhesion with the substrate. The thermal conductivity of the coating had been studied by a heat conduction coefficient measurement device; results proved that it reached 11.2 W/m × K at a hydro-thermal temperature of 400 ℃, far higher than that of organic coating. MDPI 2022-02-15 /pmc/articles/PMC8876477/ /pubmed/35207985 http://dx.doi.org/10.3390/ma15041447 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Debo Zhang, Baofeng Song, Wei Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment |
title | Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment |
title_full | Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment |
title_fullStr | Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment |
title_full_unstemmed | Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment |
title_short | Improving the Anti-Corrosion and Anti-Wear Performance of Anodic Coating on the Surface of AA 5052 via Hydro-Thermal Treatment |
title_sort | improving the anti-corrosion and anti-wear performance of anodic coating on the surface of aa 5052 via hydro-thermal treatment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8876477/ https://www.ncbi.nlm.nih.gov/pubmed/35207985 http://dx.doi.org/10.3390/ma15041447 |
work_keys_str_mv | AT liudebo improvingtheanticorrosionandantiwearperformanceofanodiccoatingonthesurfaceofaa5052viahydrothermaltreatment AT zhangbaofeng improvingtheanticorrosionandantiwearperformanceofanodiccoatingonthesurfaceofaa5052viahydrothermaltreatment AT songwei improvingtheanticorrosionandantiwearperformanceofanodiccoatingonthesurfaceofaa5052viahydrothermaltreatment |