Cargando…
Extrafine Beclometasone Dipropionate/Formoterol NEXThaler on Device Usability, Adherence, Asthma Control and Quality of Life. A Panhellenic Prospective, Non-Interventional Observational Study in Patients with Asthma—The NEXT-Step Study
Background: The fixed combination of extrafine beclometasone dipropionate 100 μg/formoterol 6 μg (extrafine BDP/F) delivered by NEXThaler has proved to be effective in patients with moderate-to-severe asthma in terms of lung function, symptoms and asthma control. The aim of this study was to investi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8876660/ https://www.ncbi.nlm.nih.gov/pubmed/35207635 http://dx.doi.org/10.3390/jpm12020146 |
Sumario: | Background: The fixed combination of extrafine beclometasone dipropionate 100 μg/formoterol 6 μg (extrafine BDP/F) delivered by NEXThaler has proved to be effective in patients with moderate-to-severe asthma in terms of lung function, symptoms and asthma control. The aim of this study was to investigate the usability/satisfaction of NEXThaler and adherence to treatment in asthma patients not well controlled by low-dose inhaled corticosteroids (ICS). Methods: This was a 6-month prospective, multicenter, open-label, observational study in 661 patients with asthma not well controlled by low-dose ICS according to the physician’s clinical assessment, which have received regular treatment with extrafine BDP/F NEXThaler. Feeling of Satisfaction with Inhaler (FSI), treatment adherence with self-reported Morisky scale, asthma control, lung function and QoL were recorded at baseline, 3 and 6 months after treatment with extrafine BDP/F. Results: The percentage of patients at least “fairly” satisfied with NEXThaler usability (FSI-10 score 40 to 50) was 96.3%. The mean FSI-10 total score was 46.8 ± 4.4 on Visit 2 and increased to 48.1 ± 3.3 on Visit 3 (p < 0.001). Approximately 67% of the patients reported “high adherence” on Visit 2, and 70% of them reported “high adherence” on Visit 3. The percentage of patients with ACQ-6-uncontrolled asthma decreased from 79.1% on Visit 1 to 22.3% on Visit 2 and further decreased to 6.7% on Visit 3. Significant improvements were also observed in the total AQLQ score, predicted FEV1% and reduction in rescue medication use. Conclusions: The NEXThaler device, delivering a combination of BDP/F, achieves satisfaction and high adherence in patients with asthma not well controlled with low-dose ICS. Asthma control, QoL, lung function and rescue medication use were improved in a Greek real-world setting. |
---|