Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates

The increasingly widespread diffusion of wearable devices makes possible the continuous monitoring of vital signs, such as heart rate (HR), heart rate variability (HRV), and breath signal. However, these devices usually do not record the “gold-standard” signals, namely the electrocardiography (ECG)...

Descripción completa

Detalles Bibliográficos
Autores principales: Reali, Pierluigi, Lolatto, Riccardo, Coelli, Stefania, Tartaglia, Gabriella, Bianchi, Anna Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8877143/
https://www.ncbi.nlm.nih.gov/pubmed/35214329
http://dx.doi.org/10.3390/s22041428
_version_ 1784658341033672704
author Reali, Pierluigi
Lolatto, Riccardo
Coelli, Stefania
Tartaglia, Gabriella
Bianchi, Anna Maria
author_facet Reali, Pierluigi
Lolatto, Riccardo
Coelli, Stefania
Tartaglia, Gabriella
Bianchi, Anna Maria
author_sort Reali, Pierluigi
collection PubMed
description The increasingly widespread diffusion of wearable devices makes possible the continuous monitoring of vital signs, such as heart rate (HR), heart rate variability (HRV), and breath signal. However, these devices usually do not record the “gold-standard” signals, namely the electrocardiography (ECG) and respiratory activity, but a single photoplethysmographic (PPG) signal, which can be exploited to estimate HR and respiratory activity. In addition, these devices employ low sampling rates to limit power consumption. Hence, proper methods should be adopted to compensate for the resulting increased discretization error, while diverse breath-extraction algorithms may be differently sensitive to PPG sampling rate. Here, we assessed the efficacy of parabola interpolation, cubic-spline, and linear regression methods to improve the accuracy of the inter-beat intervals (IBIs) extracted from PPG sampled at decreasing rates from 64 to 8 Hz. PPG-derived IBIs and HRV indices were compared with those extracted from a standard ECG. In addition, breath signals extracted from PPG using three different techniques were compared with the gold-standard signal from a thoracic belt. Signals were recorded from eight healthy volunteers during an experimental protocol comprising sitting and standing postures and a controlled respiration task. Parabola and cubic-spline interpolation significantly increased IBIs accuracy at 32, 16, and 8 Hz sampling rates. Concerning breath signal extraction, the method holding higher accuracy was based on PPG bandpass filtering. Our results support the efficacy of parabola and spline interpolations to improve the accuracy of the IBIs obtained from low-sampling rate PPG signals, and also indicate a robust method for breath signal extraction.
format Online
Article
Text
id pubmed-8877143
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88771432022-02-26 Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates Reali, Pierluigi Lolatto, Riccardo Coelli, Stefania Tartaglia, Gabriella Bianchi, Anna Maria Sensors (Basel) Article The increasingly widespread diffusion of wearable devices makes possible the continuous monitoring of vital signs, such as heart rate (HR), heart rate variability (HRV), and breath signal. However, these devices usually do not record the “gold-standard” signals, namely the electrocardiography (ECG) and respiratory activity, but a single photoplethysmographic (PPG) signal, which can be exploited to estimate HR and respiratory activity. In addition, these devices employ low sampling rates to limit power consumption. Hence, proper methods should be adopted to compensate for the resulting increased discretization error, while diverse breath-extraction algorithms may be differently sensitive to PPG sampling rate. Here, we assessed the efficacy of parabola interpolation, cubic-spline, and linear regression methods to improve the accuracy of the inter-beat intervals (IBIs) extracted from PPG sampled at decreasing rates from 64 to 8 Hz. PPG-derived IBIs and HRV indices were compared with those extracted from a standard ECG. In addition, breath signals extracted from PPG using three different techniques were compared with the gold-standard signal from a thoracic belt. Signals were recorded from eight healthy volunteers during an experimental protocol comprising sitting and standing postures and a controlled respiration task. Parabola and cubic-spline interpolation significantly increased IBIs accuracy at 32, 16, and 8 Hz sampling rates. Concerning breath signal extraction, the method holding higher accuracy was based on PPG bandpass filtering. Our results support the efficacy of parabola and spline interpolations to improve the accuracy of the IBIs obtained from low-sampling rate PPG signals, and also indicate a robust method for breath signal extraction. MDPI 2022-02-13 /pmc/articles/PMC8877143/ /pubmed/35214329 http://dx.doi.org/10.3390/s22041428 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Reali, Pierluigi
Lolatto, Riccardo
Coelli, Stefania
Tartaglia, Gabriella
Bianchi, Anna Maria
Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates
title Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates
title_full Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates
title_fullStr Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates
title_full_unstemmed Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates
title_short Information Retrieval from Photoplethysmographic Sensors: A Comprehensive Comparison of Practical Interpolation and Breath-Extraction Techniques at Different Sampling Rates
title_sort information retrieval from photoplethysmographic sensors: a comprehensive comparison of practical interpolation and breath-extraction techniques at different sampling rates
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8877143/
https://www.ncbi.nlm.nih.gov/pubmed/35214329
http://dx.doi.org/10.3390/s22041428
work_keys_str_mv AT realipierluigi informationretrievalfromphotoplethysmographicsensorsacomprehensivecomparisonofpracticalinterpolationandbreathextractiontechniquesatdifferentsamplingrates
AT lolattoriccardo informationretrievalfromphotoplethysmographicsensorsacomprehensivecomparisonofpracticalinterpolationandbreathextractiontechniquesatdifferentsamplingrates
AT coellistefania informationretrievalfromphotoplethysmographicsensorsacomprehensivecomparisonofpracticalinterpolationandbreathextractiontechniquesatdifferentsamplingrates
AT tartagliagabriella informationretrievalfromphotoplethysmographicsensorsacomprehensivecomparisonofpracticalinterpolationandbreathextractiontechniquesatdifferentsamplingrates
AT bianchiannamaria informationretrievalfromphotoplethysmographicsensorsacomprehensivecomparisonofpracticalinterpolationandbreathextractiontechniquesatdifferentsamplingrates