Cargando…

Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project

A quality assurance/quality control program was implemented in the framework of the EU project HBM4EU to assess and improve the comparability of biomarker analysis and to build a network of competent laboratories. Four rounds of proficiency tests were organized for 15 phthalate and two DINCH urinary...

Descripción completa

Detalles Bibliográficos
Autores principales: Mol, Hans G. J., Elbers, Ingrid, Pälmke, Claudia, Bury, Daniel, Göen, Thomas, López, Marta Esteban, Nübler, Stefanie, Vaccher, Vincent, Antignac, Jean-Philippe, Dvořáková, Darina, Hajšlová, Jana, Sakhi, Amrit Kaur, Thomsen, Cathrine, Vorkamp, Katrin, Castaño, Argelia, Koch, Holger M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8878211/
https://www.ncbi.nlm.nih.gov/pubmed/35202244
http://dx.doi.org/10.3390/toxics10020057
_version_ 1784658608145825792
author Mol, Hans G. J.
Elbers, Ingrid
Pälmke, Claudia
Bury, Daniel
Göen, Thomas
López, Marta Esteban
Nübler, Stefanie
Vaccher, Vincent
Antignac, Jean-Philippe
Dvořáková, Darina
Hajšlová, Jana
Sakhi, Amrit Kaur
Thomsen, Cathrine
Vorkamp, Katrin
Castaño, Argelia
Koch, Holger M.
author_facet Mol, Hans G. J.
Elbers, Ingrid
Pälmke, Claudia
Bury, Daniel
Göen, Thomas
López, Marta Esteban
Nübler, Stefanie
Vaccher, Vincent
Antignac, Jean-Philippe
Dvořáková, Darina
Hajšlová, Jana
Sakhi, Amrit Kaur
Thomsen, Cathrine
Vorkamp, Katrin
Castaño, Argelia
Koch, Holger M.
author_sort Mol, Hans G. J.
collection PubMed
description A quality assurance/quality control program was implemented in the framework of the EU project HBM4EU to assess and improve the comparability of biomarker analysis and to build a network of competent laboratories. Four rounds of proficiency tests were organized for 15 phthalate and two DINCH urinary biomarkers (0.2–138 ng/mL) over a period of 18 months, with the involvement of 28 laboratories. A substantial improvement in performance was observed after the first round in particular, and by the end of the program, an average satisfactory performance rate of 90% was achieved. The interlaboratory reproducibility as derived from the participants’ results varied for the various biomarkers and rounds, with an average of 24% for the biomarkers of eight single-isomer phthalates (e.g., DnBP and DEHP) and 43% for the more challenging biomarkers of the mixed-isomer phthalates (DiNP, DiDP) and DINCH. When the reproducibility was based only on the laboratories that consistently achieved a satisfactory performance, this improved to 17% and 26%, respectively, clearly demonstrating the success of the QA/QC efforts. The program thus aided in building capacity and the establishment of a network of competent laboratories able to generate comparable and accurate HBM data for phthalate and DINCH biomarkers in 14 EU countries. In addition, global comparability was ensured by including external expert laboratories.
format Online
Article
Text
id pubmed-8878211
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88782112022-02-26 Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project Mol, Hans G. J. Elbers, Ingrid Pälmke, Claudia Bury, Daniel Göen, Thomas López, Marta Esteban Nübler, Stefanie Vaccher, Vincent Antignac, Jean-Philippe Dvořáková, Darina Hajšlová, Jana Sakhi, Amrit Kaur Thomsen, Cathrine Vorkamp, Katrin Castaño, Argelia Koch, Holger M. Toxics Article A quality assurance/quality control program was implemented in the framework of the EU project HBM4EU to assess and improve the comparability of biomarker analysis and to build a network of competent laboratories. Four rounds of proficiency tests were organized for 15 phthalate and two DINCH urinary biomarkers (0.2–138 ng/mL) over a period of 18 months, with the involvement of 28 laboratories. A substantial improvement in performance was observed after the first round in particular, and by the end of the program, an average satisfactory performance rate of 90% was achieved. The interlaboratory reproducibility as derived from the participants’ results varied for the various biomarkers and rounds, with an average of 24% for the biomarkers of eight single-isomer phthalates (e.g., DnBP and DEHP) and 43% for the more challenging biomarkers of the mixed-isomer phthalates (DiNP, DiDP) and DINCH. When the reproducibility was based only on the laboratories that consistently achieved a satisfactory performance, this improved to 17% and 26%, respectively, clearly demonstrating the success of the QA/QC efforts. The program thus aided in building capacity and the establishment of a network of competent laboratories able to generate comparable and accurate HBM data for phthalate and DINCH biomarkers in 14 EU countries. In addition, global comparability was ensured by including external expert laboratories. MDPI 2022-01-26 /pmc/articles/PMC8878211/ /pubmed/35202244 http://dx.doi.org/10.3390/toxics10020057 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mol, Hans G. J.
Elbers, Ingrid
Pälmke, Claudia
Bury, Daniel
Göen, Thomas
López, Marta Esteban
Nübler, Stefanie
Vaccher, Vincent
Antignac, Jean-Philippe
Dvořáková, Darina
Hajšlová, Jana
Sakhi, Amrit Kaur
Thomsen, Cathrine
Vorkamp, Katrin
Castaño, Argelia
Koch, Holger M.
Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project
title Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project
title_full Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project
title_fullStr Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project
title_full_unstemmed Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project
title_short Proficiency and Interlaboratory Variability in the Determination of Phthalate and DINCH Biomarkers in Human Urine: Results from the HBM4EU Project
title_sort proficiency and interlaboratory variability in the determination of phthalate and dinch biomarkers in human urine: results from the hbm4eu project
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8878211/
https://www.ncbi.nlm.nih.gov/pubmed/35202244
http://dx.doi.org/10.3390/toxics10020057
work_keys_str_mv AT molhansgj proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT elbersingrid proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT palmkeclaudia proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT burydaniel proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT goenthomas proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT lopezmartaesteban proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT nublerstefanie proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT vacchervincent proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT antignacjeanphilippe proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT dvorakovadarina proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT hajslovajana proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT sakhiamritkaur proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT thomsencathrine proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT vorkampkatrin proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT castanoargelia proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject
AT kochholgerm proficiencyandinterlaboratoryvariabilityinthedeterminationofphthalateanddinchbiomarkersinhumanurineresultsfromthehbm4euproject