Cargando…
Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart
The CUSUM control chart is suitable for detecting small to moderate parameter shifts for processes involving autocorrelated data. The average run length (ARL) can be used to assess the ability of a CUSUM control chart to detect changes in a long-memory seasonal autoregressive fractionally integrated...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8880929/ https://www.ncbi.nlm.nih.gov/pubmed/35213619 http://dx.doi.org/10.1371/journal.pone.0264283 |
_version_ | 1784659352707137536 |
---|---|
author | Areepong, Yupaporn Peerajit, Wilasinee |
author_facet | Areepong, Yupaporn Peerajit, Wilasinee |
author_sort | Areepong, Yupaporn |
collection | PubMed |
description | The CUSUM control chart is suitable for detecting small to moderate parameter shifts for processes involving autocorrelated data. The average run length (ARL) can be used to assess the ability of a CUSUM control chart to detect changes in a long-memory seasonal autoregressive fractionally integrated moving average with exogenous variable (SARFIMAX) process with underlying exponential white noise. Herein, new ARLs via an analytical integral equation (IE) solution as an analytical IE and a numerical IE method to test a CUSUM control chart’s ability to detect a wide range of shifts in the mean of a SARFIMAX(P, D, Q, r)(s) process with underlying exponential white noise are presented. The analytical IE formulas were derived by using the Fredholm integral equation of the second type while the numerical IE method for the approximate ARL is based on quadrature rules. After applying Banach’s fixed-point theorem to guarantee its existence and uniqueness, the precision of the proposed analytical IE ARL was the same as the numerical IE method. The sensitivity and accuracy of the ARLs based on both methods were assessed on a CUSUM control chart running a SARFIMAX(P, D, Q, r)(s) process with underlying exponential white noise. The results of an extensive numerical study comprising the examination of a wide variety of out-of-control situations and computational schemes reveal that none of the methods outperformed the IE. Specifically, the computational scheme is easier and can be completed in one step. Hence, it is recommended for use in this situation. An illustrative example based on real data is also provided, the results of which were found to be in accordance with the research results. |
format | Online Article Text |
id | pubmed-8880929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-88809292022-02-26 Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart Areepong, Yupaporn Peerajit, Wilasinee PLoS One Research Article The CUSUM control chart is suitable for detecting small to moderate parameter shifts for processes involving autocorrelated data. The average run length (ARL) can be used to assess the ability of a CUSUM control chart to detect changes in a long-memory seasonal autoregressive fractionally integrated moving average with exogenous variable (SARFIMAX) process with underlying exponential white noise. Herein, new ARLs via an analytical integral equation (IE) solution as an analytical IE and a numerical IE method to test a CUSUM control chart’s ability to detect a wide range of shifts in the mean of a SARFIMAX(P, D, Q, r)(s) process with underlying exponential white noise are presented. The analytical IE formulas were derived by using the Fredholm integral equation of the second type while the numerical IE method for the approximate ARL is based on quadrature rules. After applying Banach’s fixed-point theorem to guarantee its existence and uniqueness, the precision of the proposed analytical IE ARL was the same as the numerical IE method. The sensitivity and accuracy of the ARLs based on both methods were assessed on a CUSUM control chart running a SARFIMAX(P, D, Q, r)(s) process with underlying exponential white noise. The results of an extensive numerical study comprising the examination of a wide variety of out-of-control situations and computational schemes reveal that none of the methods outperformed the IE. Specifically, the computational scheme is easier and can be completed in one step. Hence, it is recommended for use in this situation. An illustrative example based on real data is also provided, the results of which were found to be in accordance with the research results. Public Library of Science 2022-02-25 /pmc/articles/PMC8880929/ /pubmed/35213619 http://dx.doi.org/10.1371/journal.pone.0264283 Text en © 2022 Areepong, Peerajit https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Areepong, Yupaporn Peerajit, Wilasinee Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart |
title | Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart |
title_full | Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart |
title_fullStr | Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart |
title_full_unstemmed | Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart |
title_short | Integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal ARFIMAX(P, D, Q, r)(s) process running on a CUSUM control chart |
title_sort | integral equation solutions for the average run length for monitoring shifts in the mean of a generalized seasonal arfimax(p, d, q, r)(s) process running on a cusum control chart |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8880929/ https://www.ncbi.nlm.nih.gov/pubmed/35213619 http://dx.doi.org/10.1371/journal.pone.0264283 |
work_keys_str_mv | AT areepongyupaporn integralequationsolutionsfortheaveragerunlengthformonitoringshiftsinthemeanofageneralizedseasonalarfimaxpdqrsprocessrunningonacusumcontrolchart AT peerajitwilasinee integralequationsolutionsfortheaveragerunlengthformonitoringshiftsinthemeanofageneralizedseasonalarfimaxpdqrsprocessrunningonacusumcontrolchart |