Cargando…

Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial

BACKGROUND: Total knee arthroplasty (TKA) is now frequently performed and is highly successful. However, patient satisfaction after TKA is often difficult to achieve. Because of the presence of metallic prosthetic knee joints, there is a lack of imaging tools that can accurately assess the patient&#...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Zhengyu, Qu, Xinhua, Zhao, Yaochao, Yuan, Zhiguo, Zheng, Liangjun, Long, Teng, Yao, Qiuying, Yue, Bing, Wang, You
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8882580/
https://www.ncbi.nlm.nih.gov/pubmed/35237649
http://dx.doi.org/10.3389/fsurg.2022.809699
_version_ 1784659723480465408
author Cai, Zhengyu
Qu, Xinhua
Zhao, Yaochao
Yuan, Zhiguo
Zheng, Liangjun
Long, Teng
Yao, Qiuying
Yue, Bing
Wang, You
author_facet Cai, Zhengyu
Qu, Xinhua
Zhao, Yaochao
Yuan, Zhiguo
Zheng, Liangjun
Long, Teng
Yao, Qiuying
Yue, Bing
Wang, You
author_sort Cai, Zhengyu
collection PubMed
description BACKGROUND: Total knee arthroplasty (TKA) is now frequently performed and is highly successful. However, patient satisfaction after TKA is often difficult to achieve. Because of the presence of metallic prosthetic knee joints, there is a lack of imaging tools that can accurately assess the patient's postoperative prosthetic position, soft tissue impingement, and periprosthetic bone density after TKA. We conducted a clinical trial of the world's first totally modular polyetheretherketone (PEEK) TKA and determined the bone density values in the stress concentration area around the prosthesis based on postoperative computed tomography data to reconstruct a three-dimensional model of the PEEK prosthetic knee joint after implantation. Based on the model, the overhang of the prosthesis was measured at various locations on the prosthesis. METHODS: All patients who underwent PEEK-based TKA were postoperatively assessed with radiography and computed tomography (CT). Hounsfield units (HUs) for the different components of the quantitative CT assessment were measured separately. RESULTS: Ten patients (nine female and one male) aged 59–74 (mean 66.9, median 67) years were included. The HU values were as follows: PEEK prosthesis mean 182.95, standard deviation (SD) 4.90, coefficient of variation (CV) 2.68; polyethylene mean −89.41, SD 4.14, CV −4.63; lateral femoral osteochondral mean 192.19, SD 55.05, CV 28.64; lateral tibial osteochondral mean 122.94, SD 62.14, CV 42.86; medial femoral osteophyte mean 180.76, SD 43.48, CV 24.05; and medial tibial osteophyte mean 282.59, SD 69.28, CV 24.52. Analysis of the data at 1, 3, and 6 months showed that the mean PE (p = 0.598) and PEEK (p = 0.916) measurements did not change with the time of measurement. There was a decrease in bone mineral density in the lateral tibia at 3 months (p = 0.044). Otherwise, there was no significant change in bone density in other regions (p = 0.124–0.803). There was no overhang in all femoral prostheses, whereas there were two cases of overhang in tibial prostheses. Overhang measurements do not differ significantly across time points. The overhang measurements were not significantly different at all time points (p = 0.186–0.967). CONCLUSION: PEEK knee joint prosthesis has excellent CT compatibility. The change in periprosthetic bone volume during the follow-up period can be determined using the HU value after CT scan, while the prosthesis position can be assessed. This assessment may potentially guide future improvements in knee prosthesis alignment techniques and artificial knee prosthesis designs.
format Online
Article
Text
id pubmed-8882580
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88825802022-03-01 Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial Cai, Zhengyu Qu, Xinhua Zhao, Yaochao Yuan, Zhiguo Zheng, Liangjun Long, Teng Yao, Qiuying Yue, Bing Wang, You Front Surg Surgery BACKGROUND: Total knee arthroplasty (TKA) is now frequently performed and is highly successful. However, patient satisfaction after TKA is often difficult to achieve. Because of the presence of metallic prosthetic knee joints, there is a lack of imaging tools that can accurately assess the patient's postoperative prosthetic position, soft tissue impingement, and periprosthetic bone density after TKA. We conducted a clinical trial of the world's first totally modular polyetheretherketone (PEEK) TKA and determined the bone density values in the stress concentration area around the prosthesis based on postoperative computed tomography data to reconstruct a three-dimensional model of the PEEK prosthetic knee joint after implantation. Based on the model, the overhang of the prosthesis was measured at various locations on the prosthesis. METHODS: All patients who underwent PEEK-based TKA were postoperatively assessed with radiography and computed tomography (CT). Hounsfield units (HUs) for the different components of the quantitative CT assessment were measured separately. RESULTS: Ten patients (nine female and one male) aged 59–74 (mean 66.9, median 67) years were included. The HU values were as follows: PEEK prosthesis mean 182.95, standard deviation (SD) 4.90, coefficient of variation (CV) 2.68; polyethylene mean −89.41, SD 4.14, CV −4.63; lateral femoral osteochondral mean 192.19, SD 55.05, CV 28.64; lateral tibial osteochondral mean 122.94, SD 62.14, CV 42.86; medial femoral osteophyte mean 180.76, SD 43.48, CV 24.05; and medial tibial osteophyte mean 282.59, SD 69.28, CV 24.52. Analysis of the data at 1, 3, and 6 months showed that the mean PE (p = 0.598) and PEEK (p = 0.916) measurements did not change with the time of measurement. There was a decrease in bone mineral density in the lateral tibia at 3 months (p = 0.044). Otherwise, there was no significant change in bone density in other regions (p = 0.124–0.803). There was no overhang in all femoral prostheses, whereas there were two cases of overhang in tibial prostheses. Overhang measurements do not differ significantly across time points. The overhang measurements were not significantly different at all time points (p = 0.186–0.967). CONCLUSION: PEEK knee joint prosthesis has excellent CT compatibility. The change in periprosthetic bone volume during the follow-up period can be determined using the HU value after CT scan, while the prosthesis position can be assessed. This assessment may potentially guide future improvements in knee prosthesis alignment techniques and artificial knee prosthesis designs. Frontiers Media S.A. 2022-02-14 /pmc/articles/PMC8882580/ /pubmed/35237649 http://dx.doi.org/10.3389/fsurg.2022.809699 Text en Copyright © 2022 Cai, Qu, Zhao, Yuan, Zheng, Long, Yao, Yue and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Cai, Zhengyu
Qu, Xinhua
Zhao, Yaochao
Yuan, Zhiguo
Zheng, Liangjun
Long, Teng
Yao, Qiuying
Yue, Bing
Wang, You
Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial
title Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial
title_full Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial
title_fullStr Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial
title_full_unstemmed Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial
title_short Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial
title_sort preliminary study on immediate postoperative ct images and values of the modular polyetheretherketone based total knee arthroplasty: an observational first-in-human trial
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8882580/
https://www.ncbi.nlm.nih.gov/pubmed/35237649
http://dx.doi.org/10.3389/fsurg.2022.809699
work_keys_str_mv AT caizhengyu preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT quxinhua preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT zhaoyaochao preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT yuanzhiguo preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT zhengliangjun preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT longteng preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT yaoqiuying preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT yuebing preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial
AT wangyou preliminarystudyonimmediatepostoperativectimagesandvaluesofthemodularpolyetheretherketonebasedtotalkneearthroplastyanobservationalfirstinhumantrial