Cargando…

Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope

PURPOSE: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic c...

Descripción completa

Detalles Bibliográficos
Autores principales: Condor Montes, Shivany Y., Bennett, Daniel, Bensinger, Ethan, Rani, Lakshmisahithi, Sherkat, Younes, Zhao, Chao, Helft, Zachary, Roorda, Austin, Green, Ari J., Sheehy, Christy K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8883154/
https://www.ncbi.nlm.nih.gov/pubmed/35201339
http://dx.doi.org/10.1167/tvst.11.2.35
_version_ 1784659863885840384
author Condor Montes, Shivany Y.
Bennett, Daniel
Bensinger, Ethan
Rani, Lakshmisahithi
Sherkat, Younes
Zhao, Chao
Helft, Zachary
Roorda, Austin
Green, Ari J.
Sheehy, Christy K.
author_facet Condor Montes, Shivany Y.
Bennett, Daniel
Bensinger, Ethan
Rani, Lakshmisahithi
Sherkat, Younes
Zhao, Chao
Helft, Zachary
Roorda, Austin
Green, Ari J.
Sheehy, Christy K.
author_sort Condor Montes, Shivany Y.
collection PubMed
description PURPOSE: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). METHODS: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. RESULTS: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s(2) (4,186.84 degrees/s(2)). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). CONCLUSIONS: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.
format Online
Article
Text
id pubmed-8883154
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-88831542022-03-01 Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope Condor Montes, Shivany Y. Bennett, Daniel Bensinger, Ethan Rani, Lakshmisahithi Sherkat, Younes Zhao, Chao Helft, Zachary Roorda, Austin Green, Ari J. Sheehy, Christy K. Transl Vis Sci Technol Article PURPOSE: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). METHODS: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. RESULTS: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s(2) (4,186.84 degrees/s(2)). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). CONCLUSIONS: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change. The Association for Research in Vision and Ophthalmology 2022-02-24 /pmc/articles/PMC8883154/ /pubmed/35201339 http://dx.doi.org/10.1167/tvst.11.2.35 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Condor Montes, Shivany Y.
Bennett, Daniel
Bensinger, Ethan
Rani, Lakshmisahithi
Sherkat, Younes
Zhao, Chao
Helft, Zachary
Roorda, Austin
Green, Ari J.
Sheehy, Christy K.
Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope
title Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope
title_full Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope
title_fullStr Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope
title_full_unstemmed Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope
title_short Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope
title_sort characterizing fixational eye motion variance over time as recorded by the tracking scanning laser ophthalmoscope
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8883154/
https://www.ncbi.nlm.nih.gov/pubmed/35201339
http://dx.doi.org/10.1167/tvst.11.2.35
work_keys_str_mv AT condormontesshivanyy characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT bennettdaniel characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT bensingerethan characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT ranilakshmisahithi characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT sherkatyounes characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT zhaochao characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT helftzachary characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT roordaaustin characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT greenarij characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope
AT sheehychristyk characterizingfixationaleyemotionvarianceovertimeasrecordedbythetrackingscanninglaserophthalmoscope