Cargando…

Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease

BACKGROUND: Rest/stress myocardial CT perfusion (CTP) has high diagnostic value for coronary artery disease (CAD), but the additional value of resting CTP especially dual-energy CTP (DE-CTP) beyond coronary CT angiography (CCTA) in chest pain triage remains unclear. We aimed to evaluate the diagnost...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Wenhuan, Yu, Fangfang, Liu, Mingxi, Yan, Chengxi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8883697/
https://www.ncbi.nlm.nih.gov/pubmed/35220940
http://dx.doi.org/10.1186/s12880-022-00761-1
_version_ 1784660001821818880
author Li, Wenhuan
Yu, Fangfang
Liu, Mingxi
Yan, Chengxi
author_facet Li, Wenhuan
Yu, Fangfang
Liu, Mingxi
Yan, Chengxi
author_sort Li, Wenhuan
collection PubMed
description BACKGROUND: Rest/stress myocardial CT perfusion (CTP) has high diagnostic value for coronary artery disease (CAD), but the additional value of resting CTP especially dual-energy CTP (DE-CTP) beyond coronary CT angiography (CCTA) in chest pain triage remains unclear. We aimed to evaluate the diagnostic accuracy of resting myocardial DE-CTP, and additional value in detecting CAD beyond CCTA (obstructive stenosis: ≥ 50%) in patients suspected of CAD. METHODS: In this prespecified subanalysis of 54 patients, we included patients suspected of CAD referred to invasive coronary angiography (ICA). Diagnostic accuracy of resting myocardial DE-CTP in detecting myocardial perfusion defects was assessed using resting (13)N-ammonia positron emission tomography (PET) as the gold standard. Diagnostic accuracy of cardiac dual-energy CT in detecting flow-limiting stenoses (justifying revascularization) by CCTA combined with resting myocardial DE-CTP, using ICA plus resting (13)N-ammonia PET as the gold standard. The CCTA and DE-CTP datasets derived from a single-phase scan performed with dual-energy mode. RESULTS: For detecting myocardial perfusion defects, DE-CTP demonstrated high diagnostic accuracy with a sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of 95.52%, 85.93%, and 0.907 on a per-segment basis. For detecting flow-limiting stenoses by CCTA alone, sensitivity, specificity, and AUC were 100%, 56.47%, and 0.777 respectively on a per-vessel basis. For detecting flow-limiting stenoses by CCTA combined with resting myocardial DE-CTP, sensitivity, specificity, and AUC were 96.10%, 95.29% and 0.956 respectively on a per-vessel basis. Additionally, CCTA combined with resting myocardial DE-CTP detected five patients (9%) with no obstructive stenosis but with myocardial perfusion defects confirmed by ICA plus (13)N-ammonia PET. CONCLUSIONS: Resting cardiac DE-CTP demonstrates a high diagnostic accuracy in detecting myocardial perfusion defects and provides an additional clinical value by reducing rates of false-positive and false-negative patients beyond CCTA in patients suspected of CAD.
format Online
Article
Text
id pubmed-8883697
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88836972022-03-07 Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease Li, Wenhuan Yu, Fangfang Liu, Mingxi Yan, Chengxi BMC Med Imaging Research BACKGROUND: Rest/stress myocardial CT perfusion (CTP) has high diagnostic value for coronary artery disease (CAD), but the additional value of resting CTP especially dual-energy CTP (DE-CTP) beyond coronary CT angiography (CCTA) in chest pain triage remains unclear. We aimed to evaluate the diagnostic accuracy of resting myocardial DE-CTP, and additional value in detecting CAD beyond CCTA (obstructive stenosis: ≥ 50%) in patients suspected of CAD. METHODS: In this prespecified subanalysis of 54 patients, we included patients suspected of CAD referred to invasive coronary angiography (ICA). Diagnostic accuracy of resting myocardial DE-CTP in detecting myocardial perfusion defects was assessed using resting (13)N-ammonia positron emission tomography (PET) as the gold standard. Diagnostic accuracy of cardiac dual-energy CT in detecting flow-limiting stenoses (justifying revascularization) by CCTA combined with resting myocardial DE-CTP, using ICA plus resting (13)N-ammonia PET as the gold standard. The CCTA and DE-CTP datasets derived from a single-phase scan performed with dual-energy mode. RESULTS: For detecting myocardial perfusion defects, DE-CTP demonstrated high diagnostic accuracy with a sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of 95.52%, 85.93%, and 0.907 on a per-segment basis. For detecting flow-limiting stenoses by CCTA alone, sensitivity, specificity, and AUC were 100%, 56.47%, and 0.777 respectively on a per-vessel basis. For detecting flow-limiting stenoses by CCTA combined with resting myocardial DE-CTP, sensitivity, specificity, and AUC were 96.10%, 95.29% and 0.956 respectively on a per-vessel basis. Additionally, CCTA combined with resting myocardial DE-CTP detected five patients (9%) with no obstructive stenosis but with myocardial perfusion defects confirmed by ICA plus (13)N-ammonia PET. CONCLUSIONS: Resting cardiac DE-CTP demonstrates a high diagnostic accuracy in detecting myocardial perfusion defects and provides an additional clinical value by reducing rates of false-positive and false-negative patients beyond CCTA in patients suspected of CAD. BioMed Central 2022-02-27 /pmc/articles/PMC8883697/ /pubmed/35220940 http://dx.doi.org/10.1186/s12880-022-00761-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Li, Wenhuan
Yu, Fangfang
Liu, Mingxi
Yan, Chengxi
Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
title Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
title_full Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
title_fullStr Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
title_full_unstemmed Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
title_short Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
title_sort clinical value of resting cardiac dual-energy ct in patients suspected of coronary artery disease
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8883697/
https://www.ncbi.nlm.nih.gov/pubmed/35220940
http://dx.doi.org/10.1186/s12880-022-00761-1
work_keys_str_mv AT liwenhuan clinicalvalueofrestingcardiacdualenergyctinpatientssuspectedofcoronaryarterydisease
AT yufangfang clinicalvalueofrestingcardiacdualenergyctinpatientssuspectedofcoronaryarterydisease
AT liumingxi clinicalvalueofrestingcardiacdualenergyctinpatientssuspectedofcoronaryarterydisease
AT yanchengxi clinicalvalueofrestingcardiacdualenergyctinpatientssuspectedofcoronaryarterydisease