A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
PURPOSE: The main purpose of this study was to assess the radiopacity of contemporary restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials and the impact of material composition as measured by energy-dispersive X-ray spectrophotometry (EDX) on radiopacity. MATERIALS A...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8885173/ https://www.ncbi.nlm.nih.gov/pubmed/35237329 http://dx.doi.org/10.1155/2022/4131176 |
_version_ | 1784660342827122688 |
---|---|
author | Elhelbawy, Nahla Gamal Ghouraba, Rehab F Hasaneen, Fatma A |
author_facet | Elhelbawy, Nahla Gamal Ghouraba, Rehab F Hasaneen, Fatma A |
author_sort | Elhelbawy, Nahla Gamal |
collection | PubMed |
description | PURPOSE: The main purpose of this study was to assess the radiopacity of contemporary restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials and the impact of material composition as measured by energy-dispersive X-ray spectrophotometry (EDX) on radiopacity. MATERIALS AND METHODS: Ten specimens of six CAD/CAM materials with 1 mm thickness were produced and then digitally radiographed with an aluminum (Al) step-wedge (SW) and 1 mm thick tooth slice. The specimen mean gray values (MGVs) were recorded in pixels and compared to an Al-SW, dentin, and enamel of equal thickness. For the elementary analysis of the composition of the materials, EDX was performed. RESULTS: The recorded MGVs ranged between 21.20 ± 4.94 and 238.5 ± 13.61 pixels. Materials were sorted according to the MGVs descendingly, Prettau, Vita Suprinity, Vita Enamic, Shofu, Pekkton, and BioHPP. Prettau and Vita Suprinity had significantly higher MGV than dentin and 1 mm thick Al. In comparison, Vita Enamic had a slightly higher value than dentin and 1 mm thick Al. Although Pekkton and BioHPP had MGV significantly lower than dentin and 1 mm thick Al, Shofu had a significantly lower value than dentin and nonsignificantly lower than 1 mm thick Al (p < 0.05). According to EDX analysis, the examined materials contained several components in varying quantities of radiopacity. CONCLUSIONS: The radiopacity of only three studied materials exceeded the International Organization for Standardization's minimum standards (ISO). |
format | Online Article Text |
id | pubmed-8885173 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-88851732022-03-01 A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition Elhelbawy, Nahla Gamal Ghouraba, Rehab F Hasaneen, Fatma A Int J Biomater Research Article PURPOSE: The main purpose of this study was to assess the radiopacity of contemporary restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials and the impact of material composition as measured by energy-dispersive X-ray spectrophotometry (EDX) on radiopacity. MATERIALS AND METHODS: Ten specimens of six CAD/CAM materials with 1 mm thickness were produced and then digitally radiographed with an aluminum (Al) step-wedge (SW) and 1 mm thick tooth slice. The specimen mean gray values (MGVs) were recorded in pixels and compared to an Al-SW, dentin, and enamel of equal thickness. For the elementary analysis of the composition of the materials, EDX was performed. RESULTS: The recorded MGVs ranged between 21.20 ± 4.94 and 238.5 ± 13.61 pixels. Materials were sorted according to the MGVs descendingly, Prettau, Vita Suprinity, Vita Enamic, Shofu, Pekkton, and BioHPP. Prettau and Vita Suprinity had significantly higher MGV than dentin and 1 mm thick Al. In comparison, Vita Enamic had a slightly higher value than dentin and 1 mm thick Al. Although Pekkton and BioHPP had MGV significantly lower than dentin and 1 mm thick Al, Shofu had a significantly lower value than dentin and nonsignificantly lower than 1 mm thick Al (p < 0.05). According to EDX analysis, the examined materials contained several components in varying quantities of radiopacity. CONCLUSIONS: The radiopacity of only three studied materials exceeded the International Organization for Standardization's minimum standards (ISO). Hindawi 2022-02-21 /pmc/articles/PMC8885173/ /pubmed/35237329 http://dx.doi.org/10.1155/2022/4131176 Text en Copyright © 2022 Nahla Gamal Elhelbawy et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Elhelbawy, Nahla Gamal Ghouraba, Rehab F Hasaneen, Fatma A A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition |
title | A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition |
title_full | A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition |
title_fullStr | A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition |
title_full_unstemmed | A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition |
title_short | A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition |
title_sort | comparative evaluation of the radiopacity of contemporary restorative cad/cam blocks using digital radiography based on the impact of material composition |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8885173/ https://www.ncbi.nlm.nih.gov/pubmed/35237329 http://dx.doi.org/10.1155/2022/4131176 |
work_keys_str_mv | AT elhelbawynahlagamal acomparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition AT ghourabarehabf acomparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition AT hasaneenfatmaa acomparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition AT elhelbawynahlagamal comparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition AT ghourabarehabf comparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition AT hasaneenfatmaa comparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition |