PURPOSE: The main purpose of this study was to assess the radiopacity of contemporary restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials and the impact of material composition as measured by energy-dispersive X-ray spectrophotometry (EDX) on radiopacity. MATERIALS A...

Descripción completa

Detalles Bibliográficos
Autores principales: Elhelbawy, Nahla Gamal, Ghouraba, Rehab F, Hasaneen, Fatma A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8885173/
https://www.ncbi.nlm.nih.gov/pubmed/35237329
http://dx.doi.org/10.1155/2022/4131176
_version_ 1784660342827122688
author Elhelbawy, Nahla Gamal
Ghouraba, Rehab F
Hasaneen, Fatma A
author_facet Elhelbawy, Nahla Gamal
Ghouraba, Rehab F
Hasaneen, Fatma A
author_sort Elhelbawy, Nahla Gamal
collection PubMed
description PURPOSE: The main purpose of this study was to assess the radiopacity of contemporary restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials and the impact of material composition as measured by energy-dispersive X-ray spectrophotometry (EDX) on radiopacity. MATERIALS AND METHODS: Ten specimens of six CAD/CAM materials with 1 mm thickness were produced and then digitally radiographed with an aluminum (Al) step-wedge (SW) and 1 mm thick tooth slice. The specimen mean gray values (MGVs) were recorded in pixels and compared to an Al-SW, dentin, and enamel of equal thickness. For the elementary analysis of the composition of the materials, EDX was performed. RESULTS: The recorded MGVs ranged between 21.20 ± 4.94 and 238.5 ± 13.61 pixels. Materials were sorted according to the MGVs descendingly, Prettau, Vita Suprinity, Vita Enamic, Shofu, Pekkton, and BioHPP. Prettau and Vita Suprinity had significantly higher MGV than dentin and 1 mm thick Al. In comparison, Vita Enamic had a slightly higher value than dentin and 1 mm thick Al. Although Pekkton and BioHPP had MGV significantly lower than dentin and 1 mm thick Al, Shofu had a significantly lower value than dentin and nonsignificantly lower than 1 mm thick Al (p < 0.05). According to EDX analysis, the examined materials contained several components in varying quantities of radiopacity. CONCLUSIONS: The radiopacity of only three studied materials exceeded the International Organization for Standardization's minimum standards (ISO).
format Online
Article
Text
id pubmed-8885173
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-88851732022-03-01 A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition Elhelbawy, Nahla Gamal Ghouraba, Rehab F Hasaneen, Fatma A Int J Biomater Research Article PURPOSE: The main purpose of this study was to assess the radiopacity of contemporary restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials and the impact of material composition as measured by energy-dispersive X-ray spectrophotometry (EDX) on radiopacity. MATERIALS AND METHODS: Ten specimens of six CAD/CAM materials with 1 mm thickness were produced and then digitally radiographed with an aluminum (Al) step-wedge (SW) and 1 mm thick tooth slice. The specimen mean gray values (MGVs) were recorded in pixels and compared to an Al-SW, dentin, and enamel of equal thickness. For the elementary analysis of the composition of the materials, EDX was performed. RESULTS: The recorded MGVs ranged between 21.20 ± 4.94 and 238.5 ± 13.61 pixels. Materials were sorted according to the MGVs descendingly, Prettau, Vita Suprinity, Vita Enamic, Shofu, Pekkton, and BioHPP. Prettau and Vita Suprinity had significantly higher MGV than dentin and 1 mm thick Al. In comparison, Vita Enamic had a slightly higher value than dentin and 1 mm thick Al. Although Pekkton and BioHPP had MGV significantly lower than dentin and 1 mm thick Al, Shofu had a significantly lower value than dentin and nonsignificantly lower than 1 mm thick Al (p < 0.05). According to EDX analysis, the examined materials contained several components in varying quantities of radiopacity. CONCLUSIONS: The radiopacity of only three studied materials exceeded the International Organization for Standardization's minimum standards (ISO). Hindawi 2022-02-21 /pmc/articles/PMC8885173/ /pubmed/35237329 http://dx.doi.org/10.1155/2022/4131176 Text en Copyright © 2022 Nahla Gamal Elhelbawy et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Elhelbawy, Nahla Gamal
Ghouraba, Rehab F
Hasaneen, Fatma A
A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
title A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
title_full A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
title_fullStr A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
title_full_unstemmed A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
title_short A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition
title_sort comparative evaluation of the radiopacity of contemporary restorative cad/cam blocks using digital radiography based on the impact of material composition
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8885173/
https://www.ncbi.nlm.nih.gov/pubmed/35237329
http://dx.doi.org/10.1155/2022/4131176
work_keys_str_mv AT elhelbawynahlagamal acomparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition
AT ghourabarehabf acomparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition
AT hasaneenfatmaa acomparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition
AT elhelbawynahlagamal comparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition
AT ghourabarehabf comparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition
AT hasaneenfatmaa comparativeevaluationoftheradiopacityofcontemporaryrestorativecadcamblocksusingdigitalradiographybasedontheimpactofmaterialcomposition