Cargando…
Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection
A 50‐year‐old man with a medical history of diabetes mellitus and hypertension was admitted to a university hospital for severe respiratory insufficiency caused by SARS‐CoV‐2 infection. His arterial blood pressure and blood oxygen levels were monitored through a plastic cannula inserted in the radia...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886644/ https://www.ncbi.nlm.nih.gov/pubmed/35251646 http://dx.doi.org/10.1002/ccr3.5509 |
_version_ | 1784660711397392384 |
---|---|
author | Washimi, Soichiro Yamada, Takeshi Takahashi, Akihiko |
author_facet | Washimi, Soichiro Yamada, Takeshi Takahashi, Akihiko |
author_sort | Washimi, Soichiro |
collection | PubMed |
description | A 50‐year‐old man with a medical history of diabetes mellitus and hypertension was admitted to a university hospital for severe respiratory insufficiency caused by SARS‐CoV‐2 infection. His arterial blood pressure and blood oxygen levels were monitored through a plastic cannula inserted in the radial artery in the intensive care unit. After recovery from respiratory insufficiency, the patient was moved to a local hospital where hematoma formation and skin necrosis at the puncture site were noted. On the 25th day from the initial admission, the patient developed massive bleeding from the wound on the hematoma and was transferred to our hospital on emergency. A 6‐Fr sheath introducer was inserted through the right distal radial artery in the anatomical snuff box, and instant hemostasis was accomplished without external compression. Thereafter, percutaneous thrombin injection for the pseudoaneurysm was conducted under ultrasound guidance. However, bleeding from the pseudoaneurysm was still observed after radial sheath withdrawal. We then performed coil embolization of the radial artery, which involved a coil proximal to the aneurysm, four coils in the neck of the aneurysm, and two coils distal to the aneurysm. Permanent hemostasis was achieved with no further vascular complications. |
format | Online Article Text |
id | pubmed-8886644 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88866442022-03-04 Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection Washimi, Soichiro Yamada, Takeshi Takahashi, Akihiko Clin Case Rep Case Reports A 50‐year‐old man with a medical history of diabetes mellitus and hypertension was admitted to a university hospital for severe respiratory insufficiency caused by SARS‐CoV‐2 infection. His arterial blood pressure and blood oxygen levels were monitored through a plastic cannula inserted in the radial artery in the intensive care unit. After recovery from respiratory insufficiency, the patient was moved to a local hospital where hematoma formation and skin necrosis at the puncture site were noted. On the 25th day from the initial admission, the patient developed massive bleeding from the wound on the hematoma and was transferred to our hospital on emergency. A 6‐Fr sheath introducer was inserted through the right distal radial artery in the anatomical snuff box, and instant hemostasis was accomplished without external compression. Thereafter, percutaneous thrombin injection for the pseudoaneurysm was conducted under ultrasound guidance. However, bleeding from the pseudoaneurysm was still observed after radial sheath withdrawal. We then performed coil embolization of the radial artery, which involved a coil proximal to the aneurysm, four coils in the neck of the aneurysm, and two coils distal to the aneurysm. Permanent hemostasis was achieved with no further vascular complications. John Wiley and Sons Inc. 2022-03-01 /pmc/articles/PMC8886644/ /pubmed/35251646 http://dx.doi.org/10.1002/ccr3.5509 Text en © 2022 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Reports Washimi, Soichiro Yamada, Takeshi Takahashi, Akihiko Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection |
title | Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection |
title_full | Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection |
title_fullStr | Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection |
title_full_unstemmed | Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection |
title_short | Successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with SARS‐CoV‐2 infection |
title_sort | successful coil embolization with distal radial access for a ruptured radial artery pseudoaneurysm in a patient with sars‐cov‐2 infection |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886644/ https://www.ncbi.nlm.nih.gov/pubmed/35251646 http://dx.doi.org/10.1002/ccr3.5509 |
work_keys_str_mv | AT washimisoichiro successfulcoilembolizationwithdistalradialaccessforarupturedradialarterypseudoaneurysminapatientwithsarscov2infection AT yamadatakeshi successfulcoilembolizationwithdistalradialaccessforarupturedradialarterypseudoaneurysminapatientwithsarscov2infection AT takahashiakihiko successfulcoilembolizationwithdistalradialaccessforarupturedradialarterypseudoaneurysminapatientwithsarscov2infection |