Cargando…

Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report

BACKGROUND: Coronary obstruction (CO) is an infrequent but life-threatening complication during transcatheter aortic valve replacement (TAVR). CASE SUMMARY: We report the case of a patient who accepted TAVR with high anatomical risks of CO due to the small congenital left coronary sinus, which was t...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Chen, Song, Guangyuan, Niu, Guannan, Wu, Yongjian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886909/
https://www.ncbi.nlm.nih.gov/pubmed/35243204
http://dx.doi.org/10.1093/ehjcr/ytac011
_version_ 1784660781708607488
author Yang, Chen
Song, Guangyuan
Niu, Guannan
Wu, Yongjian
author_facet Yang, Chen
Song, Guangyuan
Niu, Guannan
Wu, Yongjian
author_sort Yang, Chen
collection PubMed
description BACKGROUND: Coronary obstruction (CO) is an infrequent but life-threatening complication during transcatheter aortic valve replacement (TAVR). CASE SUMMARY: We report the case of a patient who accepted TAVR with high anatomical risks of CO due to the small congenital left coronary sinus, which was treated with preliminary coronary protection. This case highlighted the importance of computed tomography angiography (CTA) evaluation, 3D-printing stimulation, predilation as a reference sign, and pre-emptive chimney stenting technology to successfully anticipate and prevent CO during TAVR. At the 3rd month follow-up, CTA evaluation and 3D-printing simulation identified the chimney stenting of the left main coronary arterial patency. DISCUSSION: A ‘four-step assessment’ method also proposes a new clinical procedure on how to perform TAVR in patients with high risks of CO.
format Online
Article
Text
id pubmed-8886909
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-88869092022-03-02 Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report Yang, Chen Song, Guangyuan Niu, Guannan Wu, Yongjian Eur Heart J Case Rep Case Report BACKGROUND: Coronary obstruction (CO) is an infrequent but life-threatening complication during transcatheter aortic valve replacement (TAVR). CASE SUMMARY: We report the case of a patient who accepted TAVR with high anatomical risks of CO due to the small congenital left coronary sinus, which was treated with preliminary coronary protection. This case highlighted the importance of computed tomography angiography (CTA) evaluation, 3D-printing stimulation, predilation as a reference sign, and pre-emptive chimney stenting technology to successfully anticipate and prevent CO during TAVR. At the 3rd month follow-up, CTA evaluation and 3D-printing simulation identified the chimney stenting of the left main coronary arterial patency. DISCUSSION: A ‘four-step assessment’ method also proposes a new clinical procedure on how to perform TAVR in patients with high risks of CO. Oxford University Press 2022-01-24 /pmc/articles/PMC8886909/ /pubmed/35243204 http://dx.doi.org/10.1093/ehjcr/ytac011 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Yang, Chen
Song, Guangyuan
Niu, Guannan
Wu, Yongjian
Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
title Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
title_full Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
title_fullStr Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
title_full_unstemmed Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
title_short Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
title_sort coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886909/
https://www.ncbi.nlm.nih.gov/pubmed/35243204
http://dx.doi.org/10.1093/ehjcr/ytac011
work_keys_str_mv AT yangchen coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport
AT songguangyuan coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport
AT niuguannan coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport
AT wuyongjian coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport