Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report
BACKGROUND: Coronary obstruction (CO) is an infrequent but life-threatening complication during transcatheter aortic valve replacement (TAVR). CASE SUMMARY: We report the case of a patient who accepted TAVR with high anatomical risks of CO due to the small congenital left coronary sinus, which was t...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886909/ https://www.ncbi.nlm.nih.gov/pubmed/35243204 http://dx.doi.org/10.1093/ehjcr/ytac011 |
_version_ | 1784660781708607488 |
---|---|
author | Yang, Chen Song, Guangyuan Niu, Guannan Wu, Yongjian |
author_facet | Yang, Chen Song, Guangyuan Niu, Guannan Wu, Yongjian |
author_sort | Yang, Chen |
collection | PubMed |
description | BACKGROUND: Coronary obstruction (CO) is an infrequent but life-threatening complication during transcatheter aortic valve replacement (TAVR). CASE SUMMARY: We report the case of a patient who accepted TAVR with high anatomical risks of CO due to the small congenital left coronary sinus, which was treated with preliminary coronary protection. This case highlighted the importance of computed tomography angiography (CTA) evaluation, 3D-printing stimulation, predilation as a reference sign, and pre-emptive chimney stenting technology to successfully anticipate and prevent CO during TAVR. At the 3rd month follow-up, CTA evaluation and 3D-printing simulation identified the chimney stenting of the left main coronary arterial patency. DISCUSSION: A ‘four-step assessment’ method also proposes a new clinical procedure on how to perform TAVR in patients with high risks of CO. |
format | Online Article Text |
id | pubmed-8886909 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-88869092022-03-02 Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report Yang, Chen Song, Guangyuan Niu, Guannan Wu, Yongjian Eur Heart J Case Rep Case Report BACKGROUND: Coronary obstruction (CO) is an infrequent but life-threatening complication during transcatheter aortic valve replacement (TAVR). CASE SUMMARY: We report the case of a patient who accepted TAVR with high anatomical risks of CO due to the small congenital left coronary sinus, which was treated with preliminary coronary protection. This case highlighted the importance of computed tomography angiography (CTA) evaluation, 3D-printing stimulation, predilation as a reference sign, and pre-emptive chimney stenting technology to successfully anticipate and prevent CO during TAVR. At the 3rd month follow-up, CTA evaluation and 3D-printing simulation identified the chimney stenting of the left main coronary arterial patency. DISCUSSION: A ‘four-step assessment’ method also proposes a new clinical procedure on how to perform TAVR in patients with high risks of CO. Oxford University Press 2022-01-24 /pmc/articles/PMC8886909/ /pubmed/35243204 http://dx.doi.org/10.1093/ehjcr/ytac011 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Yang, Chen Song, Guangyuan Niu, Guannan Wu, Yongjian Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
title | Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
title_full | Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
title_fullStr | Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
title_full_unstemmed | Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
title_short | Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
title_sort | coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886909/ https://www.ncbi.nlm.nih.gov/pubmed/35243204 http://dx.doi.org/10.1093/ehjcr/ytac011 |
work_keys_str_mv | AT yangchen coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport AT songguangyuan coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport AT niuguannan coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport AT wuyongjian coronaryprotectionforthesmallleftcoronarysinusduringtranscatheteraorticvalvereplacementacasereport |