Cargando…

Sensitivity, Specificity, and Safety of a Novel ESAT6-CFP10 Skin Test for Tuberculosis Infection in China: 2 Randomized, Self-Controlled, Parallel-Group Phase 2b Trials

BACKGROUND: Diagnostics to identify tuberculosis infection are limited. We aimed to assess the diagnostic accuracy and safety of ESAT6-CFP10 (EC) skin test for tuberculosis infection in Chinese adults. METHODS: We conducted 2 randomized, parallel-group clinical trials in healthy participants and tub...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Miao, Lu, Wei, Li, Tao, Li, Jingxin, Du, Weixin, Wu, Qi, Liu, Qiao, Yuan, Baodong, Lu, Jinbiao, Ding, Xiaoyan, Li, Feng, Liu, Min, Chen, Baowen, Pu, Jiang, Zhang, Rongping, Xi, Xiuhong, Zhou, Rongguang, Mei, Zaoxian, Du, Ronghui, Tao, Lifeng, Martinez, Leonardo, Lu, Shuihua, Wang, Guozhi, Zhu, Fengcai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8886919/
https://www.ncbi.nlm.nih.gov/pubmed/34021314
http://dx.doi.org/10.1093/cid/ciab472
Descripción
Sumario:BACKGROUND: Diagnostics to identify tuberculosis infection are limited. We aimed to assess the diagnostic accuracy and safety of ESAT6-CFP10 (EC) skin test for tuberculosis infection in Chinese adults. METHODS: We conducted 2 randomized, parallel-group clinical trials in healthy participants and tuberculosis patients. All participants were tested with the T-SPOT.TB test, then received an EC skin test and tuberculin skin test (TST). The diameter of skin indurations and/or redness at injection sites were measured at different time periods. A bacillus Calmette Guerin (BCG) model was established to assess the diagnosis of tuberculosis infection using an EC skin test. RESULTS: In total, 777 healthy participants and 96 tuberculosis patients were allocated to receive EC skin test at 1.0 μg/0.1 mL or 0.5 μg/0.1 mL. The area under the curve was 0.95 (95% confidence interval [CI], .91–.97) for the EC skin test at 1.0 μg/0.1 mL at 24–72 hours. Compared with the T-SPOT.TB test, the EC skin test demonstrated similar sensitivity (87.5, 95% CI, 77.8–97.2 vs 86.5, 95% CI, 79.5–93.4) and specificity (98.9, 95% CI, 96.0–99.9 vs 96.1, 95% CI, 93.5–97.8). Among BCG vaccinated participants, the EC skin test had high consistency with the T-SPOT.TB test (96.3, 95% CI, 92.0–100.0). No serious adverse events related to the EC skin test were observed. CONCLUSIONS: The EC skin test demonstrated both high specificity and sensitivity at a dose of 1.0 μg/0.1 mL, comparable to the T-SPOT.TB test. The diagnostic accuracy of the EC skin test was not impacted by BCG vaccination. CLINICAL TRIALS REGISTRATION: NCT02389322 and NCT02336542.