Cargando…

Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing

PURPOSE: The three-dimensional (3D) sequence of magnetic resonance imaging (MRI) plays a critical role in the imaging of musculoskeletal joints; however, its long acquisition time limits its clinical application. In such conditions, compressed sensing (CS) is introduced to accelerate MRI in clinical...

Descripción completa

Detalles Bibliográficos
Autores principales: Sui, He, Li, Jin, Liu, Lin, Lv, Zhongwen, Zhang, Yunfei, Dai, Yongming, Mo, Zhanhao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8887673/
https://www.ncbi.nlm.nih.gov/pubmed/35241934
http://dx.doi.org/10.2147/JPR.S345210
_version_ 1784660956771516416
author Sui, He
Li, Jin
Liu, Lin
Lv, Zhongwen
Zhang, Yunfei
Dai, Yongming
Mo, Zhanhao
author_facet Sui, He
Li, Jin
Liu, Lin
Lv, Zhongwen
Zhang, Yunfei
Dai, Yongming
Mo, Zhanhao
author_sort Sui, He
collection PubMed
description PURPOSE: The three-dimensional (3D) sequence of magnetic resonance imaging (MRI) plays a critical role in the imaging of musculoskeletal joints; however, its long acquisition time limits its clinical application. In such conditions, compressed sensing (CS) is introduced to accelerate MRI in clinical practice. We aimed to investigate the feasibility of an isotropic 3D variable-flip-angle fast spin echo (FSE) sequence with CS technique (CS-MATRIX) compared to conventional 2D sequences in knee imaging. METHODS: Images from different sequences of both the accelerated CS-MATRIX and the corresponding conventional acquisitions were prospectively analyzed and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the structures within the knees were measured for quantitative analysis. The subjective image quality and diagnostic agreement were compared between CS-MATRIX and conventional 2D sequences. Quantitative and subjective image quality scores were statistically analyzed with the paired t-test and Wilcoxon signed-rank test, respectively. Diagnostic agreements of knee substructure were assessed using Cohen’s weighted kappa statistic. RESULTS: For quantitative analysis, images from the CS-MATRIX sequence showed a significantly higher SNR than T2-fs 2D sequences for visualizing cartilage, menisci, and ligaments, as well as a higher SNR than proton density (pd) 2D sequences for visualizing menisci and ligaments. There was no significant difference between CS-MATRIX and 2D T2-fs sequences in subjective image quality assessment. The diagnostic agreement was rated as moderate to very good between CS-MATRIX and 2D sequences. CONCLUSION: This study demonstrates the feasibility and clinical potential of the CS-MATRIX sequence technique for detecting knee lesions The CS-MATRIX sequence allows for faster knee imaging than conventional 2D sequences, yielding similar image quality to 2D sequences.
format Online
Article
Text
id pubmed-8887673
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-88876732022-03-02 Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing Sui, He Li, Jin Liu, Lin Lv, Zhongwen Zhang, Yunfei Dai, Yongming Mo, Zhanhao J Pain Res Original Research PURPOSE: The three-dimensional (3D) sequence of magnetic resonance imaging (MRI) plays a critical role in the imaging of musculoskeletal joints; however, its long acquisition time limits its clinical application. In such conditions, compressed sensing (CS) is introduced to accelerate MRI in clinical practice. We aimed to investigate the feasibility of an isotropic 3D variable-flip-angle fast spin echo (FSE) sequence with CS technique (CS-MATRIX) compared to conventional 2D sequences in knee imaging. METHODS: Images from different sequences of both the accelerated CS-MATRIX and the corresponding conventional acquisitions were prospectively analyzed and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the structures within the knees were measured for quantitative analysis. The subjective image quality and diagnostic agreement were compared between CS-MATRIX and conventional 2D sequences. Quantitative and subjective image quality scores were statistically analyzed with the paired t-test and Wilcoxon signed-rank test, respectively. Diagnostic agreements of knee substructure were assessed using Cohen’s weighted kappa statistic. RESULTS: For quantitative analysis, images from the CS-MATRIX sequence showed a significantly higher SNR than T2-fs 2D sequences for visualizing cartilage, menisci, and ligaments, as well as a higher SNR than proton density (pd) 2D sequences for visualizing menisci and ligaments. There was no significant difference between CS-MATRIX and 2D T2-fs sequences in subjective image quality assessment. The diagnostic agreement was rated as moderate to very good between CS-MATRIX and 2D sequences. CONCLUSION: This study demonstrates the feasibility and clinical potential of the CS-MATRIX sequence technique for detecting knee lesions The CS-MATRIX sequence allows for faster knee imaging than conventional 2D sequences, yielding similar image quality to 2D sequences. Dove 2022-02-25 /pmc/articles/PMC8887673/ /pubmed/35241934 http://dx.doi.org/10.2147/JPR.S345210 Text en © 2022 Sui et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Sui, He
Li, Jin
Liu, Lin
Lv, Zhongwen
Zhang, Yunfei
Dai, Yongming
Mo, Zhanhao
Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing
title Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing
title_full Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing
title_fullStr Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing
title_full_unstemmed Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing
title_short Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing
title_sort accelerating knee mri: 3d modulated flip-angle technique in refocused imaging with an extended echo train and compressed sensing
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8887673/
https://www.ncbi.nlm.nih.gov/pubmed/35241934
http://dx.doi.org/10.2147/JPR.S345210
work_keys_str_mv AT suihe acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing
AT lijin acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing
AT liulin acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing
AT lvzhongwen acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing
AT zhangyunfei acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing
AT daiyongming acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing
AT mozhanhao acceleratingkneemri3dmodulatedflipangletechniqueinrefocusedimagingwithanextendedechotrainandcompressedsensing