Cargando…

Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome

Situs inversus with dextrocardia is a rare congenital anomaly that presents a unique challenge for the consultant electrophysiologist. Implantation of cardiac device in these patients may be challenging owing to their individual cardiac and vascular anatomy. Consequently, adverse procedural outcomes...

Descripción completa

Detalles Bibliográficos
Autores principales: Hakimi, Matthew, Yabumoto, Maya, Sun, Jack, Rochon-Duck, Michael, Donaldson, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8887932/
https://www.ncbi.nlm.nih.gov/pubmed/35251758
http://dx.doi.org/10.19102/icrm.2022.130201
_version_ 1784661008333144064
author Hakimi, Matthew
Yabumoto, Maya
Sun, Jack
Rochon-Duck, Michael
Donaldson, David
author_facet Hakimi, Matthew
Yabumoto, Maya
Sun, Jack
Rochon-Duck, Michael
Donaldson, David
author_sort Hakimi, Matthew
collection PubMed
description Situs inversus with dextrocardia is a rare congenital anomaly that presents a unique challenge for the consultant electrophysiologist. Implantation of cardiac device in these patients may be challenging owing to their individual cardiac and vascular anatomy. Consequently, adverse procedural outcomes are more common in this group and an informed pre- and intraoperative approach is critical. In this article, we present the relevant patient findings and implications for the electrophysiologist, including operative approaches. We then examine them in the context of an actual case, having implanted an intracardiac permanent pacemaker with a right-sided approach via the conventional method in a patient with dextrocardia situs inversus who had undergone multiple surgeries for structural heart disease.
format Online
Article
Text
id pubmed-8887932
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-88879322022-03-03 Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome Hakimi, Matthew Yabumoto, Maya Sun, Jack Rochon-Duck, Michael Donaldson, David J Innov Card Rhythm Manag Case Report Situs inversus with dextrocardia is a rare congenital anomaly that presents a unique challenge for the consultant electrophysiologist. Implantation of cardiac device in these patients may be challenging owing to their individual cardiac and vascular anatomy. Consequently, adverse procedural outcomes are more common in this group and an informed pre- and intraoperative approach is critical. In this article, we present the relevant patient findings and implications for the electrophysiologist, including operative approaches. We then examine them in the context of an actual case, having implanted an intracardiac permanent pacemaker with a right-sided approach via the conventional method in a patient with dextrocardia situs inversus who had undergone multiple surgeries for structural heart disease. MediaSphere Medical 2022-02-15 /pmc/articles/PMC8887932/ /pubmed/35251758 http://dx.doi.org/10.19102/icrm.2022.130201 Text en Copyright: © 2022 Innovations in Cardiac Rhythm Management https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Hakimi, Matthew
Yabumoto, Maya
Sun, Jack
Rochon-Duck, Michael
Donaldson, David
Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome
title Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome
title_full Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome
title_fullStr Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome
title_full_unstemmed Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome
title_short Implantation of a Dual-chamber Pacemaker in a Patient with Dextrocardia, Situs Inversus, and Sick Sinus Syndrome
title_sort implantation of a dual-chamber pacemaker in a patient with dextrocardia, situs inversus, and sick sinus syndrome
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8887932/
https://www.ncbi.nlm.nih.gov/pubmed/35251758
http://dx.doi.org/10.19102/icrm.2022.130201
work_keys_str_mv AT hakimimatthew implantationofadualchamberpacemakerinapatientwithdextrocardiasitusinversusandsicksinussyndrome
AT yabumotomaya implantationofadualchamberpacemakerinapatientwithdextrocardiasitusinversusandsicksinussyndrome
AT sunjack implantationofadualchamberpacemakerinapatientwithdextrocardiasitusinversusandsicksinussyndrome
AT rochonduckmichael implantationofadualchamberpacemakerinapatientwithdextrocardiasitusinversusandsicksinussyndrome
AT donaldsondavid implantationofadualchamberpacemakerinapatientwithdextrocardiasitusinversusandsicksinussyndrome