Cargando…

Usefulness of endoscope-assisted surgery under exoscopic view in skull base surgery: A technical note

BACKGROUND: The use of the exoscope has been increasing in the field of neurosurgery, as it can set the visual axis freely, enabling the surgeon to operate in a comfortable posture. Although endoscope-assisted surgery for compensation of insufficient surgical field is useful under the microscope, we...

Descripción completa

Detalles Bibliográficos
Autores principales: Yano, Shigetoshi, Hiraoka, Fumihiro, Morita, Hiroya, Kawano, Hiroto, Kuwajima, Takuto, Yoshida, Shin-ichiro, Hama, Yoshiaki, Tashiro, Noriaki, Hamaguchi, Shuko, Aikawa, Hiroshi, Go, Yoshinori, Kazekawa, Kiyoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Scientific Scholar 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8888302/
https://www.ncbi.nlm.nih.gov/pubmed/35242396
http://dx.doi.org/10.25259/SNI_965_2021
Descripción
Sumario:BACKGROUND: The use of the exoscope has been increasing in the field of neurosurgery, as it can set the visual axis freely, enabling the surgeon to operate in a comfortable posture. Although endoscope-assisted surgery for compensation of insufficient surgical field is useful under the microscope, we report that using an endoscope in exoscopic surgery is safer and more useful. METHODS: The exoscope used was ORBEYE. All surgical procedures were performed exoscopically from the beginning of the surgery. When endoscopic observation was required during the operation, the endoscope was inserted under observation by an exoscope. The exoscopic screen was 4K-3D and endoscopic screen was 4K-2D, the operation was performed while observing both screens at the same time. The endoscope was held manually or by a mechanical holder. RESULTS: Twenty-two cases, including 14 requiring microvascular decompression (MVD) and eight requiring tumor removal, were performed by endoscopic-assisted exoscopic surgery. The endoscope could be inserted safely because its relationship with the surrounding structure could be observed under the exoscope, and the operator could observe both screens without moving the head. Fourteen of 22 patients required additional endoscopic treatment. Satisfactory two-handed operation was performed in 13 cases. Symptomatology disappeared in all cases of MVD, and sufficient tumor resection was achieved. CONCLUSION: Exoscopic surgery provides excellent surgical view that is not inferior to conventional microsurgery. As a large space can be secured between the scope and the surgical field, it is safer and easier to manipulate the endoscope under the exoscope.