Cargando…

Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy

Objective  The aim of this study was to compare the degree of dentinal penetration between an epoxy resin-based sealer applied by using two different filling methods and an ultrasonically activated calcium silicate-based sealer via confocal laser scanning microscopy (CLSM). Materials and Methods  Fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Dani, Yang, Sung-Eun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Private Ltd 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8890920/
https://www.ncbi.nlm.nih.gov/pubmed/34674198
http://dx.doi.org/10.1055/s-0041-1735429
_version_ 1784661753651527680
author Song, Dani
Yang, Sung-Eun
author_facet Song, Dani
Yang, Sung-Eun
author_sort Song, Dani
collection PubMed
description Objective  The aim of this study was to compare the degree of dentinal penetration between an epoxy resin-based sealer applied by using two different filling methods and an ultrasonically activated calcium silicate-based sealer via confocal laser scanning microscopy (CLSM). Materials and Methods  Forty-five extracted permanent maxillary premolars with type II canals (Vertucci’s classification) were subjected to the experiment. The root canals were instrumented and distributed randomly into the following three groups: AH Plus + continuous wave technique (AHC group); AH Plus + single cone technique (AHS group); and Endoseal MTA + single cone technique with ultrasonic activation (EMS) group. Each sealer was labeled with rhodamine B dye to allow visualization under CLSM. The sealer penetration depth in each sample was observed at 2 mm and 5 mm from the apex by using CLSM. The data were statistically analyzed by using analysis of variance or Kruskal–Wallis H test according to normality of variable (α = 0.05). Results  In all groups, the maximum sealer penetration depth, mean fluorescence intensity, and sum fluorescence intensity values were higher at the 5-mm level than at the 2-mm level. At the 5-mm level, the EMS group showed the lowest value ( p = 0.02). At the 2-mm level, there were no statistically significant differences among any of the groups. The AHC group showed higher values than the other groups, but there was no statistically significant difference in the apical area where access of instruments was difficult. Conclusion  The AHC group showed the highest dentinal tubule penetration, but had questionable filing efficacy in the apical area, which is of particular importance for the success of root canal treatment. Therefore, in areas such as the apical 2 mm of premolars with type II canals, which are difficult to access by using instruments such as heat carriers, other appropriate approaches may be required accordingly.
format Online
Article
Text
id pubmed-8890920
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Thieme Medical and Scientific Publishers Private Ltd
record_format MEDLINE/PubMed
spelling pubmed-88909202022-03-03 Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy Song, Dani Yang, Sung-Eun Eur J Dent Objective  The aim of this study was to compare the degree of dentinal penetration between an epoxy resin-based sealer applied by using two different filling methods and an ultrasonically activated calcium silicate-based sealer via confocal laser scanning microscopy (CLSM). Materials and Methods  Forty-five extracted permanent maxillary premolars with type II canals (Vertucci’s classification) were subjected to the experiment. The root canals were instrumented and distributed randomly into the following three groups: AH Plus + continuous wave technique (AHC group); AH Plus + single cone technique (AHS group); and Endoseal MTA + single cone technique with ultrasonic activation (EMS) group. Each sealer was labeled with rhodamine B dye to allow visualization under CLSM. The sealer penetration depth in each sample was observed at 2 mm and 5 mm from the apex by using CLSM. The data were statistically analyzed by using analysis of variance or Kruskal–Wallis H test according to normality of variable (α = 0.05). Results  In all groups, the maximum sealer penetration depth, mean fluorescence intensity, and sum fluorescence intensity values were higher at the 5-mm level than at the 2-mm level. At the 5-mm level, the EMS group showed the lowest value ( p = 0.02). At the 2-mm level, there were no statistically significant differences among any of the groups. The AHC group showed higher values than the other groups, but there was no statistically significant difference in the apical area where access of instruments was difficult. Conclusion  The AHC group showed the highest dentinal tubule penetration, but had questionable filing efficacy in the apical area, which is of particular importance for the success of root canal treatment. Therefore, in areas such as the apical 2 mm of premolars with type II canals, which are difficult to access by using instruments such as heat carriers, other appropriate approaches may be required accordingly. Thieme Medical and Scientific Publishers Private Ltd 2021-10-21 /pmc/articles/PMC8890920/ /pubmed/34674198 http://dx.doi.org/10.1055/s-0041-1735429 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Song, Dani
Yang, Sung-Eun
Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy
title Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy
title_full Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy
title_fullStr Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy
title_full_unstemmed Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy
title_short Comparison of Dentinal Tubule Penetration between a Calcium Silicate-Based Sealer with Ultrasonic Activation and an Epoxy Resin-Based Sealer: A Study Using Confocal Laser Scanning Microscopy
title_sort comparison of dentinal tubule penetration between a calcium silicate-based sealer with ultrasonic activation and an epoxy resin-based sealer: a study using confocal laser scanning microscopy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8890920/
https://www.ncbi.nlm.nih.gov/pubmed/34674198
http://dx.doi.org/10.1055/s-0041-1735429
work_keys_str_mv AT songdani comparisonofdentinaltubulepenetrationbetweenacalciumsilicatebasedsealerwithultrasonicactivationandanepoxyresinbasedsealerastudyusingconfocallaserscanningmicroscopy
AT yangsungeun comparisonofdentinaltubulepenetrationbetweenacalciumsilicatebasedsealerwithultrasonicactivationandanepoxyresinbasedsealerastudyusingconfocallaserscanningmicroscopy