Cargando…

Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis

OBJECTIVES: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. MATERIALS AND METHODS: In this retrospectiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Magat, Guldane, Oncu, Elif, Ozcan, Sevgi, Orhan, Kaan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Association of Oral and Maxillofacial Surgeons 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8890962/
https://www.ncbi.nlm.nih.gov/pubmed/35221306
http://dx.doi.org/10.5125/jkaoms.2022.48.1.41
_version_ 1784661766099173376
author Magat, Guldane
Oncu, Elif
Ozcan, Sevgi
Orhan, Kaan
author_facet Magat, Guldane
Oncu, Elif
Ozcan, Sevgi
Orhan, Kaan
author_sort Magat, Guldane
collection PubMed
description OBJECTIVES: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. MATERIALS AND METHODS: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. RESULTS: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (P>0.05). GSVs were not correlated with FD values (P>0.05). CONCLUSION: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality.
format Online
Article
Text
id pubmed-8890962
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Association of Oral and Maxillofacial Surgeons
record_format MEDLINE/PubMed
spelling pubmed-88909622022-03-10 Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis Magat, Guldane Oncu, Elif Ozcan, Sevgi Orhan, Kaan J Korean Assoc Oral Maxillofac Surg Original Article OBJECTIVES: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. MATERIALS AND METHODS: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. RESULTS: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (P>0.05). GSVs were not correlated with FD values (P>0.05). CONCLUSION: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality. The Korean Association of Oral and Maxillofacial Surgeons 2022-02-28 2022-02-28 /pmc/articles/PMC8890962/ /pubmed/35221306 http://dx.doi.org/10.5125/jkaoms.2022.48.1.41 Text en Copyright © 2022 The Korean Association of Oral and Maxillofacial Surgeons. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Magat, Guldane
Oncu, Elif
Ozcan, Sevgi
Orhan, Kaan
Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
title Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
title_full Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
title_fullStr Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
title_full_unstemmed Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
title_short Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
title_sort comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8890962/
https://www.ncbi.nlm.nih.gov/pubmed/35221306
http://dx.doi.org/10.5125/jkaoms.2022.48.1.41
work_keys_str_mv AT magatguldane comparisonofconebeamcomputedtomographyanddigitalpanoramicradiographyfordetectingperiimplantalveolarbonechangesusingtrabecularmicrostructureanalysis
AT oncuelif comparisonofconebeamcomputedtomographyanddigitalpanoramicradiographyfordetectingperiimplantalveolarbonechangesusingtrabecularmicrostructureanalysis
AT ozcansevgi comparisonofconebeamcomputedtomographyanddigitalpanoramicradiographyfordetectingperiimplantalveolarbonechangesusingtrabecularmicrostructureanalysis
AT orhankaan comparisonofconebeamcomputedtomographyanddigitalpanoramicradiographyfordetectingperiimplantalveolarbonechangesusingtrabecularmicrostructureanalysis