Cargando…

Reintubation Summation Calculation: A Predictive Score for Extubation Failure in Critically Ill Patients

OBJECTIVE: To derive and validate a multivariate risk score for the prediction of respiratory failure after extubation. PATIENTS AND METHODS: We performed a retrospective cohort study of adult patients admitted to the intensive care unit from January 1, 2006, to December 31, 2015, who received mecha...

Descripción completa

Detalles Bibliográficos
Autores principales: Bansal, Vikas, Smischney, Nathan J., Kashyap, Rahul, Li, Zhuo, Marquez, Alberto, Diedrich, Daniel A., Siegel, Jason L., Sen, Ayan, Tomlinson, Amanda D., Venegas-Borsellino, Carla P., Freeman, William David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8891541/
https://www.ncbi.nlm.nih.gov/pubmed/35252224
http://dx.doi.org/10.3389/fmed.2021.789440
Descripción
Sumario:OBJECTIVE: To derive and validate a multivariate risk score for the prediction of respiratory failure after extubation. PATIENTS AND METHODS: We performed a retrospective cohort study of adult patients admitted to the intensive care unit from January 1, 2006, to December 31, 2015, who received mechanical ventilation for ≥48 h. Extubation failure was defined as the need for reintubation within 72 h after extubation. Multivariate logistic regression model coefficient estimates generated the Re-Intubation Summation Calculation (RISC) score. RESULTS: The 6,161 included patients were randomly divided into 2 sets: derivation (n = 3,080) and validation (n = 3,081). Predictors of extubation failure in the derivation set included body mass index <18.5 kg/m(2) [odds ratio (OR), 1.91; 95% CI, 1.12–3.26; P = 0.02], threshold of Glasgow Coma Scale of at least 10 (OR, 1.68; 95% CI, 1.31–2.16; P < 0.001), mean airway pressure at 1 min of spontaneous breathing trial <10 cmH(2)O (OR, 2.11; 95% CI, 1.68–2.66; P < 0.001), fluid balance ≥1,500 mL 24 h preceding extubation (OR, 2.36; 95% CI, 1.87–2.96; P < 0.001), and total mechanical ventilation days ≥5 (OR, 3.94; 95% CI 3.04–5.11; P < 0.001). The C-index for the derivation and validation sets were 0.72 (95% CI, 0.70–0.75) and 0.72 (95% CI, 0.69–0.75). Multivariate logistic regression demonstrated that an increase of 1 in RISC score increased odds of extubation failure 1.6-fold (OR, 1.58; 95% CI, 1.47–1.69; P < 0.001). CONCLUSION: RISC predicts extubation failure in mechanically ventilated patients in the intensive care unit using several clinically relevant variables available in the electronic medical record but requires a larger validation cohort before widespread clinical implementation.