Cargando…
Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation
BACKGROUND: Although transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for aortic stenosis, it still carries some risks, such as valve leaks, stroke, and even death. The left ventricular global longitudinal strain (LVGLS) measurement may be useful for the prediction of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8891760/ https://www.ncbi.nlm.nih.gov/pubmed/35317147 http://dx.doi.org/10.12998/wjcc.v10.i6.1806 |
_version_ | 1784661968686153728 |
---|---|
author | Zhang, Han Xie, Jin-Jie Li, Rong-Juan Wang, Yue-Li Niu, Bao-Rong Song, Li Li, Jing Yang, Ya |
author_facet | Zhang, Han Xie, Jin-Jie Li, Rong-Juan Wang, Yue-Li Niu, Bao-Rong Song, Li Li, Jing Yang, Ya |
author_sort | Zhang, Han |
collection | PubMed |
description | BACKGROUND: Although transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for aortic stenosis, it still carries some risks, such as valve leaks, stroke, and even death. The left ventricular global longitudinal strain (LVGLS) measurement may be useful for the prediction of adverse events during this operation. AIM: To explore the change of LVGLS during TAVI procedure and the relationship between LVGLS and perioperative adverse events. METHODS: In this study, 61 patients who had undergone percutaneous transfemoral TAVI were evaluated by transthoracic echocardiography. Before surgery, data on left ventricular ejection fraction (LVEF) and LVGLS were collected separately following balloon expansion and stent implantation. Difference in values of LVGLS and LVEF during preoperative balloon expansion (pre-ex), preoperative stent implantation (pre-im) and balloon expansion-stent implantation (ex-im) were also examined. Adverse events were defined as perioperative death, cardiac rupture, heart arrest, moderate or severe perivalvular leakage, significant mitral regurgitation during TAVI, perioperative moderate or severe mitral regurgitation, perioperative left ventricular outflow tract obstruction, reoperation, and acute heart failure. RESULTS: The occurrence of perioperative adverse events was associated with differences in pre-ex LVGLS, but not with difference in pre-ex LVEF. There were significant differences between pre-LVGLS and ex-LVGLS, and between pre-LVGLS and im-LVGLS (P = 0.037 and P = 0.020, respectively). However, differences in LVEF were not significant (P = 0.358, P = 0.254); however differences in pre-ex LVGLS were associated with pre-LVGLS (P = 0.045). Compared to LVEF, LVGLS is more sensitive as a measure of left heart function during TAVI and the perioperative period. Moreover, the differences in LVGLS were associated with the occurrence of perioperative adverse events, and changes in LVGLS were apparent in patients with undesirable LVGLS before the surgery. Furthermore, LVGLS is useful to predict changes in cardiac function during TAVI. CONCLUSION: Greater attention should be paid to the patients who plan to undergo TAVI with normal LVEF but poor LVGLS. |
format | Online Article Text |
id | pubmed-8891760 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-88917602022-03-21 Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation Zhang, Han Xie, Jin-Jie Li, Rong-Juan Wang, Yue-Li Niu, Bao-Rong Song, Li Li, Jing Yang, Ya World J Clin Cases Retrospective Study BACKGROUND: Although transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for aortic stenosis, it still carries some risks, such as valve leaks, stroke, and even death. The left ventricular global longitudinal strain (LVGLS) measurement may be useful for the prediction of adverse events during this operation. AIM: To explore the change of LVGLS during TAVI procedure and the relationship between LVGLS and perioperative adverse events. METHODS: In this study, 61 patients who had undergone percutaneous transfemoral TAVI were evaluated by transthoracic echocardiography. Before surgery, data on left ventricular ejection fraction (LVEF) and LVGLS were collected separately following balloon expansion and stent implantation. Difference in values of LVGLS and LVEF during preoperative balloon expansion (pre-ex), preoperative stent implantation (pre-im) and balloon expansion-stent implantation (ex-im) were also examined. Adverse events were defined as perioperative death, cardiac rupture, heart arrest, moderate or severe perivalvular leakage, significant mitral regurgitation during TAVI, perioperative moderate or severe mitral regurgitation, perioperative left ventricular outflow tract obstruction, reoperation, and acute heart failure. RESULTS: The occurrence of perioperative adverse events was associated with differences in pre-ex LVGLS, but not with difference in pre-ex LVEF. There were significant differences between pre-LVGLS and ex-LVGLS, and between pre-LVGLS and im-LVGLS (P = 0.037 and P = 0.020, respectively). However, differences in LVEF were not significant (P = 0.358, P = 0.254); however differences in pre-ex LVGLS were associated with pre-LVGLS (P = 0.045). Compared to LVEF, LVGLS is more sensitive as a measure of left heart function during TAVI and the perioperative period. Moreover, the differences in LVGLS were associated with the occurrence of perioperative adverse events, and changes in LVGLS were apparent in patients with undesirable LVGLS before the surgery. Furthermore, LVGLS is useful to predict changes in cardiac function during TAVI. CONCLUSION: Greater attention should be paid to the patients who plan to undergo TAVI with normal LVEF but poor LVGLS. Baishideng Publishing Group Inc 2022-02-26 2022-02-26 /pmc/articles/PMC8891760/ /pubmed/35317147 http://dx.doi.org/10.12998/wjcc.v10.i6.1806 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/ |
spellingShingle | Retrospective Study Zhang, Han Xie, Jin-Jie Li, Rong-Juan Wang, Yue-Li Niu, Bao-Rong Song, Li Li, Jing Yang, Ya Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
title | Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
title_full | Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
title_fullStr | Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
title_full_unstemmed | Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
title_short | Change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
title_sort | change and impact of left ventricular global longitudinal strain during transcatheter aortic valve implantation |
topic | Retrospective Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8891760/ https://www.ncbi.nlm.nih.gov/pubmed/35317147 http://dx.doi.org/10.12998/wjcc.v10.i6.1806 |
work_keys_str_mv | AT zhanghan changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT xiejinjie changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT lirongjuan changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT wangyueli changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT niubaorong changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT songli changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT lijing changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation AT yangya changeandimpactofleftventriculargloballongitudinalstrainduringtranscatheteraorticvalveimplantation |