Cargando…
Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell
In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8892198/ https://www.ncbi.nlm.nih.gov/pubmed/35252114 http://dx.doi.org/10.3389/fchem.2022.815805 |
_version_ | 1784662100244692992 |
---|---|
author | Zhao, Guo Tran, Thien-Toan Modha, Sidharth Sedki, Mohammed Myung, Nosang V. Jassby, David Mulchandani, Ashok |
author_facet | Zhao, Guo Tran, Thien-Toan Modha, Sidharth Sedki, Mohammed Myung, Nosang V. Jassby, David Mulchandani, Ashok |
author_sort | Zhao, Guo |
collection | PubMed |
description | In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO)(2)CO(3)-reduced graphene oxide (rGO)-Nafion [(BiO)(2)CO(3)-rGO-Nafion] and Fe(3)O(4) magnetic nanoparticles (Fe(3)O(4)MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe(3)O(4)-Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices. |
format | Online Article Text |
id | pubmed-8892198 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88921982022-03-04 Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell Zhao, Guo Tran, Thien-Toan Modha, Sidharth Sedki, Mohammed Myung, Nosang V. Jassby, David Mulchandani, Ashok Front Chem Chemistry In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO)(2)CO(3)-reduced graphene oxide (rGO)-Nafion [(BiO)(2)CO(3)-rGO-Nafion] and Fe(3)O(4) magnetic nanoparticles (Fe(3)O(4)MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe(3)O(4)-Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices. Frontiers Media S.A. 2022-02-17 /pmc/articles/PMC8892198/ /pubmed/35252114 http://dx.doi.org/10.3389/fchem.2022.815805 Text en Copyright © 2022 Zhao, Tran, Modha, Sedki, Myung, Jassby and Mulchandani. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Chemistry Zhao, Guo Tran, Thien-Toan Modha, Sidharth Sedki, Mohammed Myung, Nosang V. Jassby, David Mulchandani, Ashok Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell |
title | Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell |
title_full | Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell |
title_fullStr | Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell |
title_full_unstemmed | Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell |
title_short | Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell |
title_sort | multiplexed anodic stripping voltammetry detection of heavy metals in water using nanocomposites modified screen-printed electrodes integrated with a 3d-printed flow cell |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8892198/ https://www.ncbi.nlm.nih.gov/pubmed/35252114 http://dx.doi.org/10.3389/fchem.2022.815805 |
work_keys_str_mv | AT zhaoguo multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell AT tranthientoan multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell AT modhasidharth multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell AT sedkimohammed multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell AT myungnosangv multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell AT jassbydavid multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell AT mulchandaniashok multiplexedanodicstrippingvoltammetrydetectionofheavymetalsinwaterusingnanocompositesmodifiedscreenprintedelectrodesintegratedwitha3dprintedflowcell |