Cargando…
Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition
A 55-year-old male with a history of severe organic mitral regurgitation treated with surgical mitral valve (MV) repair was referred for a transcatheter MV replacement due to recurrent regurgitation. After the release of the first transcatheter MV, a severe paravalvular leak coming from the lateral...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8893110/ https://www.ncbi.nlm.nih.gov/pubmed/35284218 http://dx.doi.org/10.4103/jcecho.jcecho_44_21 |
_version_ | 1784662324393541632 |
---|---|
author | Vairo, Alessandro Conrotto, Federico Franchin, Luca Fortuni, Federico Bruno, Francesco Montefusco, Antonio D’Ascenzo, Fabrizio Milan, Alberto Torre, Michele La Alunni, Gianluca Rinaldi, Mauro De Ferrari, Gaetano Maria |
author_facet | Vairo, Alessandro Conrotto, Federico Franchin, Luca Fortuni, Federico Bruno, Francesco Montefusco, Antonio D’Ascenzo, Fabrizio Milan, Alberto Torre, Michele La Alunni, Gianluca Rinaldi, Mauro De Ferrari, Gaetano Maria |
author_sort | Vairo, Alessandro |
collection | PubMed |
description | A 55-year-old male with a history of severe organic mitral regurgitation treated with surgical mitral valve (MV) repair was referred for a transcatheter MV replacement due to recurrent regurgitation. After the release of the first transcatheter MV, a severe paravalvular leak coming from the lateral side was observed. To promptly tackle this issue, a second valve with further postdilation was successfully implanted and the paravalvular leak disappeared. This case highlights the feasibility of implanting a second valve in case of severe paravalvular leaks after MV-in-ring procedures due to device malapposition. |
format | Online Article Text |
id | pubmed-8893110 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-88931102022-03-10 Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition Vairo, Alessandro Conrotto, Federico Franchin, Luca Fortuni, Federico Bruno, Francesco Montefusco, Antonio D’Ascenzo, Fabrizio Milan, Alberto Torre, Michele La Alunni, Gianluca Rinaldi, Mauro De Ferrari, Gaetano Maria J Cardiovasc Echogr Case Report A 55-year-old male with a history of severe organic mitral regurgitation treated with surgical mitral valve (MV) repair was referred for a transcatheter MV replacement due to recurrent regurgitation. After the release of the first transcatheter MV, a severe paravalvular leak coming from the lateral side was observed. To promptly tackle this issue, a second valve with further postdilation was successfully implanted and the paravalvular leak disappeared. This case highlights the feasibility of implanting a second valve in case of severe paravalvular leaks after MV-in-ring procedures due to device malapposition. Wolters Kluwer - Medknow 2021 2022-01-24 /pmc/articles/PMC8893110/ /pubmed/35284218 http://dx.doi.org/10.4103/jcecho.jcecho_44_21 Text en Copyright: © 2022 Journal of Cardiovascular Echography https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Vairo, Alessandro Conrotto, Federico Franchin, Luca Fortuni, Federico Bruno, Francesco Montefusco, Antonio D’Ascenzo, Fabrizio Milan, Alberto Torre, Michele La Alunni, Gianluca Rinaldi, Mauro De Ferrari, Gaetano Maria Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition |
title | Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition |
title_full | Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition |
title_fullStr | Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition |
title_full_unstemmed | Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition |
title_short | Valve-in-Valve-in-Ring: A Bailout Strategy to Tackle Paravalvular Leaks due to Device Malapposition |
title_sort | valve-in-valve-in-ring: a bailout strategy to tackle paravalvular leaks due to device malapposition |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8893110/ https://www.ncbi.nlm.nih.gov/pubmed/35284218 http://dx.doi.org/10.4103/jcecho.jcecho_44_21 |
work_keys_str_mv | AT vairoalessandro valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT conrottofederico valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT franchinluca valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT fortunifederico valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT brunofrancesco valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT montefuscoantonio valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT dascenzofabrizio valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT milanalberto valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT torremichelela valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT alunnigianluca valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT rinaldimauro valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition AT deferrarigaetanomaria valveinvalveinringabailoutstrategytotackleparavalvularleaksduetodevicemalapposition |