Cargando…

Comparison of Endothelial Dysfunction in Coronary Arteries with Bare Metal and 2 (nd) -Generation Drug-Eluting Stents

Aims: Previous studies suggested that implantation with a 1st-generation DES was associated with coronary endothelial dysfunction, which was associated with Rho-kinase activation. Second-generation drug-eluting stents (DESs) may preserve coronary endothelial function in stented coronary arteries; ho...

Descripción completa

Detalles Bibliográficos
Autores principales: Akiyama, Yusuke, Matoba, Tetsuya, Katsuki, Shunsuke, Takase, Susumu, Nakashiro, Soichi, Nakano, Yasuhiro, Noma, Kensuke, Tsutsui, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japan Atherosclerosis Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8894115/
https://www.ncbi.nlm.nih.gov/pubmed/33612554
http://dx.doi.org/10.5551/jat.61366
Descripción
Sumario:Aims: Previous studies suggested that implantation with a 1st-generation DES was associated with coronary endothelial dysfunction, which was associated with Rho-kinase activation. Second-generation drug-eluting stents (DESs) may preserve coronary endothelial function in stented coronary arteries; however, because of methodological limitations, further study is needed to clarify the association between 2 (nd) -generation DESs and coronary endothelial dysfunction. Methods: We retrospectively analysed the CuVIC trial database, where we identified 112 patients who underwent coronary stenting in the left coronary arteries with either a bare metal stent (BMS, n =53) or 2 (nd) -generation DES ( n =59). We compared vasomotions of target vessels with stents and non-target vessels without stents. Furthermore, we measured the Rho-kinase activation detected in mononucleocytes from aortic and coronary sinus blood. Results: ACh-induced vasoconstrictive responses of target vessels were not enhanced with a 2 (nd) -generation DES (45±21% vs. 44±20%, P =0.56, paired t -test), but significantly enhanced in the coronary arteries with a BMS (50±18% vs. 42±20%, P =0.002). Rho-kinase activation did not differ between patients with a BMS and 2 (nd) -generation DES. In the target vessels with a BMS, large late lumen loss and acute coronary syndrome (ACS) at the index percutaneous coronary intervention (PCI) were associated with ACh-induced enhanced coronary vasoconstrictive responses. Conclusions: Evaluation of ACh-induced vasomotion of target vessels comparing with non-target vessels revealed that 2 (nd) -generation DESs were not associated with coronary endothelial dysfunction in target vessels, nor activation of Rho-kinase in the coronary sinus blood 6-8 months after stenting.