Cargando…
Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke
BACKGROUND: It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. METHODS: Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retri...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8894307/ https://www.ncbi.nlm.nih.gov/pubmed/34936016 http://dx.doi.org/10.1007/s00062-021-01122-1 |
_version_ | 1784662627862970368 |
---|---|
author | Vogt, Marius L. Kollikowski, Alexander M. Weidner, Franziska Strinitz, Marc Feick, Jörn Essig, Fabian Neugebauer, Hermann Haeusler, Karl Georg Pham, Mirko Maerz, Alexander |
author_facet | Vogt, Marius L. Kollikowski, Alexander M. Weidner, Franziska Strinitz, Marc Feick, Jörn Essig, Fabian Neugebauer, Hermann Haeusler, Karl Georg Pham, Mirko Maerz, Alexander |
author_sort | Vogt, Marius L. |
collection | PubMed |
description | BACKGROUND: It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. METHODS: Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019–09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result. RESULTS: A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7%) treated with AP vs. 150 patients (50.3%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7% for AP vs. 79.3% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7% for AP and 16.0% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups. CONCLUSION: In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness. |
format | Online Article Text |
id | pubmed-8894307 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-88943072022-03-08 Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke Vogt, Marius L. Kollikowski, Alexander M. Weidner, Franziska Strinitz, Marc Feick, Jörn Essig, Fabian Neugebauer, Hermann Haeusler, Karl Georg Pham, Mirko Maerz, Alexander Clin Neuroradiol Original Article BACKGROUND: It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. METHODS: Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019–09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result. RESULTS: A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7%) treated with AP vs. 150 patients (50.3%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7% for AP vs. 79.3% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7% for AP and 16.0% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups. CONCLUSION: In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness. Springer Berlin Heidelberg 2021-12-09 2022 /pmc/articles/PMC8894307/ /pubmed/34936016 http://dx.doi.org/10.1007/s00062-021-01122-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Vogt, Marius L. Kollikowski, Alexander M. Weidner, Franziska Strinitz, Marc Feick, Jörn Essig, Fabian Neugebauer, Hermann Haeusler, Karl Georg Pham, Mirko Maerz, Alexander Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke |
title | Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke |
title_full | Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke |
title_fullStr | Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke |
title_full_unstemmed | Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke |
title_short | Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke |
title_sort | safety and effectiveness of the new generation aperio® hybrid stent-retriever device in large vessel occlusion stroke |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8894307/ https://www.ncbi.nlm.nih.gov/pubmed/34936016 http://dx.doi.org/10.1007/s00062-021-01122-1 |
work_keys_str_mv | AT vogtmariusl safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT kollikowskialexanderm safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT weidnerfranziska safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT strinitzmarc safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT feickjorn safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT essigfabian safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT neugebauerhermann safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT haeuslerkarlgeorg safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT phammirko safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke AT maerzalexander safetyandeffectivenessofthenewgenerationaperiohybridstentretrieverdeviceinlargevesselocclusionstroke |