A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer

Objective: To evaluate if the Halcyon(2.0) Intensity Modulation Radiotherapy (IMRT) technique has an advantage in the long-course rectal cancer radiotherapy. Methods: A total of 20 clinical IMRT plans of Halcyon(2.0) for long-course (2Gy in 25 fractions) rectal cancer radiotherapy were randomly sele...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Jiajun, Xia, Yuqing, Sun, Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8894964/
https://www.ncbi.nlm.nih.gov/pubmed/35235486
http://dx.doi.org/10.1177/15330338221074501
_version_ 1784662806707044352
author Zheng, Jiajun
Xia, Yuqing
Sun, Li
author_facet Zheng, Jiajun
Xia, Yuqing
Sun, Li
author_sort Zheng, Jiajun
collection PubMed
description Objective: To evaluate if the Halcyon(2.0) Intensity Modulation Radiotherapy (IMRT) technique has an advantage in the long-course rectal cancer radiotherapy. Methods: A total of 20 clinical IMRT plans of Halcyon(2.0) for long-course (2Gy in 25 fractions) rectal cancer radiotherapy were randomly selected. Based on the parameters of these plans, 20 TrueBeam (with the Millennium 120 MLC) plans were redesigned, respectively. The dosimetry indexes, field complexity parameters, the Gamma Passing Rates (GPR), and the delivery time of the 2 groups of plans were obtained as measures of the plan quality, the modulation complexity, the delivery accuracy, and the delivery efficiency. The differences between the 2 groups of parameters were analyzed, with P < .05 means statistically significant. Results: In terms of dosimetry, there was no significant or clinical difference between the 2 groups in critical dosimetry parameters. The Monitor Unit of the Halcyon(2.0) fields is lower than the TrueBeam fields by 26.39, while the modulation complexity score (MCS), the mean aperture area variability (AAV), and the mean leaf sequence variability (LSV) of the Halcyon(2.0) fields were 23.8%, 20%, and 2.3% larger than those of the TrueBeam fields, respectively. Neither the ArcCheck-based GPRs nor the portal-dosimetry-based GPRs in both 3%/3 mm and 2%/2 mm criteria showed the difference between the Halcyon(2.0) fields and the TrueBeam fields. The Pearson correlation coefficient between GPR(2%/2 mm) and MCS of the Halcyon(2.0) fields was 0.335, while that of the TrueBeam fields was 0.502. The mean total delivery time of the TrueBeam plans was 195.55 ± 22.86 s, while that of Halcyon(2.0) was 124.25 ± 10.42 s (P < .001), which was reduced approximatively by 36%. Conclusion: For long-course rectal cancer radiotherapy, the Halcyon(2.0) IMRT plans behave almost the same in dosimetry and delivery accuracy as the TrueBeam plans. However, the lower MU and the field modulation complexity, combined with the higher delivery efficiency, make Halcyon(2.0) a feasible and reliable platform in long-course radiotherapy for the rectal cancer.
format Online
Article
Text
id pubmed-8894964
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-88949642022-03-05 A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer Zheng, Jiajun Xia, Yuqing Sun, Li Technol Cancer Res Treat Original Article Objective: To evaluate if the Halcyon(2.0) Intensity Modulation Radiotherapy (IMRT) technique has an advantage in the long-course rectal cancer radiotherapy. Methods: A total of 20 clinical IMRT plans of Halcyon(2.0) for long-course (2Gy in 25 fractions) rectal cancer radiotherapy were randomly selected. Based on the parameters of these plans, 20 TrueBeam (with the Millennium 120 MLC) plans were redesigned, respectively. The dosimetry indexes, field complexity parameters, the Gamma Passing Rates (GPR), and the delivery time of the 2 groups of plans were obtained as measures of the plan quality, the modulation complexity, the delivery accuracy, and the delivery efficiency. The differences between the 2 groups of parameters were analyzed, with P < .05 means statistically significant. Results: In terms of dosimetry, there was no significant or clinical difference between the 2 groups in critical dosimetry parameters. The Monitor Unit of the Halcyon(2.0) fields is lower than the TrueBeam fields by 26.39, while the modulation complexity score (MCS), the mean aperture area variability (AAV), and the mean leaf sequence variability (LSV) of the Halcyon(2.0) fields were 23.8%, 20%, and 2.3% larger than those of the TrueBeam fields, respectively. Neither the ArcCheck-based GPRs nor the portal-dosimetry-based GPRs in both 3%/3 mm and 2%/2 mm criteria showed the difference between the Halcyon(2.0) fields and the TrueBeam fields. The Pearson correlation coefficient between GPR(2%/2 mm) and MCS of the Halcyon(2.0) fields was 0.335, while that of the TrueBeam fields was 0.502. The mean total delivery time of the TrueBeam plans was 195.55 ± 22.86 s, while that of Halcyon(2.0) was 124.25 ± 10.42 s (P < .001), which was reduced approximatively by 36%. Conclusion: For long-course rectal cancer radiotherapy, the Halcyon(2.0) IMRT plans behave almost the same in dosimetry and delivery accuracy as the TrueBeam plans. However, the lower MU and the field modulation complexity, combined with the higher delivery efficiency, make Halcyon(2.0) a feasible and reliable platform in long-course radiotherapy for the rectal cancer. SAGE Publications 2022-03-02 /pmc/articles/PMC8894964/ /pubmed/35235486 http://dx.doi.org/10.1177/15330338221074501 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Zheng, Jiajun
Xia, Yuqing
Sun, Li
A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer
title A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer
title_full A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer
title_fullStr A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer
title_full_unstemmed A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer
title_short A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer
title_sort comprehensive evaluation of the application of the halcyon(2.0) imrt technique in long-course radiotherapy for rectal cancer
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8894964/
https://www.ncbi.nlm.nih.gov/pubmed/35235486
http://dx.doi.org/10.1177/15330338221074501
work_keys_str_mv AT zhengjiajun acomprehensiveevaluationoftheapplicationofthehalcyon20imrttechniqueinlongcourseradiotherapyforrectalcancer
AT xiayuqing acomprehensiveevaluationoftheapplicationofthehalcyon20imrttechniqueinlongcourseradiotherapyforrectalcancer
AT sunli acomprehensiveevaluationoftheapplicationofthehalcyon20imrttechniqueinlongcourseradiotherapyforrectalcancer
AT zhengjiajun comprehensiveevaluationoftheapplicationofthehalcyon20imrttechniqueinlongcourseradiotherapyforrectalcancer
AT xiayuqing comprehensiveevaluationoftheapplicationofthehalcyon20imrttechniqueinlongcourseradiotherapyforrectalcancer
AT sunli comprehensiveevaluationoftheapplicationofthehalcyon20imrttechniqueinlongcourseradiotherapyforrectalcancer