Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study

BACKGROUND: This study was performed to evaluate periprocedural factors, complications, and repuncture rate of the newly developed puncture needle and compare it with the routinely used puncture needle for ultrasound (US)-guided paracentesis. METHODS: We retrospectively identified 137 patients who u...

Descripción completa

Detalles Bibliográficos
Autores principales: Son, Il Wan, Kim, Suk, Hong, Seung Baek, Lee, Nam Kyung, Jeong, Mi Ri, Han, Sung Yong, Woo, Hyun Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Yeungnam Medical Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8895958/
https://www.ncbi.nlm.nih.gov/pubmed/34247458
http://dx.doi.org/10.12701/yujm.2021.01109
_version_ 1784663040525860864
author Son, Il Wan
Kim, Suk
Hong, Seung Baek
Lee, Nam Kyung
Jeong, Mi Ri
Han, Sung Yong
Woo, Hyun Young
author_facet Son, Il Wan
Kim, Suk
Hong, Seung Baek
Lee, Nam Kyung
Jeong, Mi Ri
Han, Sung Yong
Woo, Hyun Young
author_sort Son, Il Wan
collection PubMed
description BACKGROUND: This study was performed to evaluate periprocedural factors, complications, and repuncture rate of the newly developed puncture needle and compare it with the routinely used puncture needle for ultrasound (US)-guided paracentesis. METHODS: We retrospectively identified 137 patients who underwent US-guided paracentesis between July 2018 and March 2019. Among them, 82 patients underwent US-guided paracentesis with a newly developed puncture needle. The other 55 patients underwent US-guided paracentesis with a routinely used puncture needle. The periprocedural factors, complications, and repuncture rate were compared between the two groups using the Mann-Whitney U test and Fisher exact test. The repuncture-associated factors were assessed using logistic regression analysis. RESULTS: There were no major or minor complications in either group. The rate of repuncture was significantly lower in the group using the newly developed puncture needle compared with the group using the routinely used puncture needle (p=0.01). The duration of the procedure was significantly shorter with the newly developed puncture needle compared with the routinely used puncture needle (p=0.01). In univariate analysis, the thickness of the abdominal wall (p=0.04) and the use of the newly developed puncture needle (p=0.01) were significantly associated with the rate of repuncture. In multivariate analysis, only the use of the newly developed puncture needle was significantly associated with the rate of repuncture. CONCLUSION: Using this novel puncture needle with a hard plastic sheath and plastic wings, the rate of repuncture and the duration of the procedure were decreased without complications of US-guided paracentesis.
format Online
Article
Text
id pubmed-8895958
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Journal of Yeungnam Medical Science
record_format MEDLINE/PubMed
spelling pubmed-88959582022-03-04 Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study Son, Il Wan Kim, Suk Hong, Seung Baek Lee, Nam Kyung Jeong, Mi Ri Han, Sung Yong Woo, Hyun Young J Yeungnam Med Sci Original Article BACKGROUND: This study was performed to evaluate periprocedural factors, complications, and repuncture rate of the newly developed puncture needle and compare it with the routinely used puncture needle for ultrasound (US)-guided paracentesis. METHODS: We retrospectively identified 137 patients who underwent US-guided paracentesis between July 2018 and March 2019. Among them, 82 patients underwent US-guided paracentesis with a newly developed puncture needle. The other 55 patients underwent US-guided paracentesis with a routinely used puncture needle. The periprocedural factors, complications, and repuncture rate were compared between the two groups using the Mann-Whitney U test and Fisher exact test. The repuncture-associated factors were assessed using logistic regression analysis. RESULTS: There were no major or minor complications in either group. The rate of repuncture was significantly lower in the group using the newly developed puncture needle compared with the group using the routinely used puncture needle (p=0.01). The duration of the procedure was significantly shorter with the newly developed puncture needle compared with the routinely used puncture needle (p=0.01). In univariate analysis, the thickness of the abdominal wall (p=0.04) and the use of the newly developed puncture needle (p=0.01) were significantly associated with the rate of repuncture. In multivariate analysis, only the use of the newly developed puncture needle was significantly associated with the rate of repuncture. CONCLUSION: Using this novel puncture needle with a hard plastic sheath and plastic wings, the rate of repuncture and the duration of the procedure were decreased without complications of US-guided paracentesis. Journal of Yeungnam Medical Science 2021-07-12 /pmc/articles/PMC8895958/ /pubmed/34247458 http://dx.doi.org/10.12701/yujm.2021.01109 Text en Copyright © 2022 Yeungnam University College of Medicine, Yeungnam University Institute of Medical Science https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Son, Il Wan
Kim, Suk
Hong, Seung Baek
Lee, Nam Kyung
Jeong, Mi Ri
Han, Sung Yong
Woo, Hyun Young
Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
title Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
title_full Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
title_fullStr Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
title_full_unstemmed Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
title_short Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
title_sort puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8895958/
https://www.ncbi.nlm.nih.gov/pubmed/34247458
http://dx.doi.org/10.12701/yujm.2021.01109
work_keys_str_mv AT sonilwan punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy
AT kimsuk punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy
AT hongseungbaek punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy
AT leenamkyung punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy
AT jeongmiri punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy
AT hansungyong punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy
AT woohyunyoung punctureneedlewithahardplasticsheathandplasticwingsminimizesrepunctureattemptsinultrasoundguidedparacentesisaretrospectivecasecontrolstudy