Cargando…

Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report

A clinical case of a 42-year-old woman patient, who had a mandibular reconstruction utilizing a three-dimensional (3D) custom-made porous titanium plate dental restoration, is presented. She showed a recurrence of a unicystic ameloblastoma involving the left hemimandible. The patient declined to be...

Descripción completa

Detalles Bibliográficos
Autores principales: Ardila, Carlos-Martín, Hernández-Arenas, Yuritza, Álvarez-Martínez, Efraín
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8896956/
https://www.ncbi.nlm.nih.gov/pubmed/35251720
http://dx.doi.org/10.1155/2022/5702066
_version_ 1784663289406423040
author Ardila, Carlos-Martín
Hernández-Arenas, Yuritza
Álvarez-Martínez, Efraín
author_facet Ardila, Carlos-Martín
Hernández-Arenas, Yuritza
Álvarez-Martínez, Efraín
author_sort Ardila, Carlos-Martín
collection PubMed
description A clinical case of a 42-year-old woman patient, who had a mandibular reconstruction utilizing a three-dimensional (3D) custom-made porous titanium plate dental restoration, is presented. She showed a recurrence of a unicystic ameloblastoma involving the left hemimandible. The patient declined to be managed by a bone-free flap. A mandibular resection in the healthy areas was provided, followed by reconstruction utilizing a 3D custom-made porous titanium plate dental restoration with a hybrid dental prosthesis. The 3D rehabilitation was created considering slim tomodensitometric sections. The cutting guides and custom-created 3D plate were fabricated employing medical software via computer-aided design and fabricating with locations planned for healing abutments. The patient was contented with the rehabilitation, and the condition continued stable at the four-year follow-up.
format Online
Article
Text
id pubmed-8896956
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-88969562022-03-05 Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report Ardila, Carlos-Martín Hernández-Arenas, Yuritza Álvarez-Martínez, Efraín Case Rep Dent Case Report A clinical case of a 42-year-old woman patient, who had a mandibular reconstruction utilizing a three-dimensional (3D) custom-made porous titanium plate dental restoration, is presented. She showed a recurrence of a unicystic ameloblastoma involving the left hemimandible. The patient declined to be managed by a bone-free flap. A mandibular resection in the healthy areas was provided, followed by reconstruction utilizing a 3D custom-made porous titanium plate dental restoration with a hybrid dental prosthesis. The 3D rehabilitation was created considering slim tomodensitometric sections. The cutting guides and custom-created 3D plate were fabricated employing medical software via computer-aided design and fabricating with locations planned for healing abutments. The patient was contented with the rehabilitation, and the condition continued stable at the four-year follow-up. Hindawi 2022-02-25 /pmc/articles/PMC8896956/ /pubmed/35251720 http://dx.doi.org/10.1155/2022/5702066 Text en Copyright © 2022 Carlos-Martín Ardila et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Ardila, Carlos-Martín
Hernández-Arenas, Yuritza
Álvarez-Martínez, Efraín
Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
title Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
title_full Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
title_fullStr Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
title_full_unstemmed Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
title_short Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
title_sort mandibular body reconstruction utilizing a three-dimensional custom-made porous titanium plate: a four-year follow-up clinical report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8896956/
https://www.ncbi.nlm.nih.gov/pubmed/35251720
http://dx.doi.org/10.1155/2022/5702066
work_keys_str_mv AT ardilacarlosmartin mandibularbodyreconstructionutilizingathreedimensionalcustommadeporoustitaniumplateafouryearfollowupclinicalreport
AT hernandezarenasyuritza mandibularbodyreconstructionutilizingathreedimensionalcustommadeporoustitaniumplateafouryearfollowupclinicalreport
AT alvarezmartinezefrain mandibularbodyreconstructionutilizingathreedimensionalcustommadeporoustitaniumplateafouryearfollowupclinicalreport