Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report
A clinical case of a 42-year-old woman patient, who had a mandibular reconstruction utilizing a three-dimensional (3D) custom-made porous titanium plate dental restoration, is presented. She showed a recurrence of a unicystic ameloblastoma involving the left hemimandible. The patient declined to be...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8896956/ https://www.ncbi.nlm.nih.gov/pubmed/35251720 http://dx.doi.org/10.1155/2022/5702066 |
_version_ | 1784663289406423040 |
---|---|
author | Ardila, Carlos-Martín Hernández-Arenas, Yuritza Álvarez-Martínez, Efraín |
author_facet | Ardila, Carlos-Martín Hernández-Arenas, Yuritza Álvarez-Martínez, Efraín |
author_sort | Ardila, Carlos-Martín |
collection | PubMed |
description | A clinical case of a 42-year-old woman patient, who had a mandibular reconstruction utilizing a three-dimensional (3D) custom-made porous titanium plate dental restoration, is presented. She showed a recurrence of a unicystic ameloblastoma involving the left hemimandible. The patient declined to be managed by a bone-free flap. A mandibular resection in the healthy areas was provided, followed by reconstruction utilizing a 3D custom-made porous titanium plate dental restoration with a hybrid dental prosthesis. The 3D rehabilitation was created considering slim tomodensitometric sections. The cutting guides and custom-created 3D plate were fabricated employing medical software via computer-aided design and fabricating with locations planned for healing abutments. The patient was contented with the rehabilitation, and the condition continued stable at the four-year follow-up. |
format | Online Article Text |
id | pubmed-8896956 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-88969562022-03-05 Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report Ardila, Carlos-Martín Hernández-Arenas, Yuritza Álvarez-Martínez, Efraín Case Rep Dent Case Report A clinical case of a 42-year-old woman patient, who had a mandibular reconstruction utilizing a three-dimensional (3D) custom-made porous titanium plate dental restoration, is presented. She showed a recurrence of a unicystic ameloblastoma involving the left hemimandible. The patient declined to be managed by a bone-free flap. A mandibular resection in the healthy areas was provided, followed by reconstruction utilizing a 3D custom-made porous titanium plate dental restoration with a hybrid dental prosthesis. The 3D rehabilitation was created considering slim tomodensitometric sections. The cutting guides and custom-created 3D plate were fabricated employing medical software via computer-aided design and fabricating with locations planned for healing abutments. The patient was contented with the rehabilitation, and the condition continued stable at the four-year follow-up. Hindawi 2022-02-25 /pmc/articles/PMC8896956/ /pubmed/35251720 http://dx.doi.org/10.1155/2022/5702066 Text en Copyright © 2022 Carlos-Martín Ardila et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Ardila, Carlos-Martín Hernández-Arenas, Yuritza Álvarez-Martínez, Efraín Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report |
title | Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report |
title_full | Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report |
title_fullStr | Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report |
title_full_unstemmed | Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report |
title_short | Mandibular Body Reconstruction Utilizing a Three-Dimensional Custom-Made Porous Titanium Plate: A Four-Year Follow-Up Clinical Report |
title_sort | mandibular body reconstruction utilizing a three-dimensional custom-made porous titanium plate: a four-year follow-up clinical report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8896956/ https://www.ncbi.nlm.nih.gov/pubmed/35251720 http://dx.doi.org/10.1155/2022/5702066 |
work_keys_str_mv | AT ardilacarlosmartin mandibularbodyreconstructionutilizingathreedimensionalcustommadeporoustitaniumplateafouryearfollowupclinicalreport AT hernandezarenasyuritza mandibularbodyreconstructionutilizingathreedimensionalcustommadeporoustitaniumplateafouryearfollowupclinicalreport AT alvarezmartinezefrain mandibularbodyreconstructionutilizingathreedimensionalcustommadeporoustitaniumplateafouryearfollowupclinicalreport |