Cargando…

Oblique lateral interbody fusion combined with different internal fixations for the treatment of degenerative lumbar spine disease: a finite element analysis

BACKGROUND: Little is known about the biomechanical performance of different internal fixations in oblique lumbar interbody fusion (OLIF). Here, finite element (FE) analysis was used to describe the biomechanics of various internal fixations and compare and explore the stability of each fixation. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Shuyi, Liu, Zhengpeng, Lu, Chenshui, Zhao, Li, Feng, Chao, Wang, Yahui, Zhang, Yilong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8897936/
https://www.ncbi.nlm.nih.gov/pubmed/35246101
http://dx.doi.org/10.1186/s12891-022-05150-x
Descripción
Sumario:BACKGROUND: Little is known about the biomechanical performance of different internal fixations in oblique lumbar interbody fusion (OLIF). Here, finite element (FE) analysis was used to describe the biomechanics of various internal fixations and compare and explore the stability of each fixation. METHODS: CT scans of a patient with lumbar degenerative disease were performed, and the l3-S1 model was constructed using relevant software. The other five FE models were constructed by simulating the model operation and adding different related implants, including (1) an intact model, (2) a stand-alone (SA) model with no instrument, (3) a unilateral pedicle screw model (UPS), (4) a unilateral pedicle screw contralateral translaminar facet screw model (UPS-CTFS), (5) a bilateral pedicle screw (BPS) model, and (6) a cortical bone trajectory screw model (CBT). Various motion loads were set by FE software to simulate lumbar vertebral activity. The software was also used to extract the range of motion (ROM) of the surgical segment, CAGE and fixation stress in the different models. RESULTS: The SA group had the greatest ROM and CAGE stress. The ROM of the BPS and UPS-CTFS was not significantly different among motion loadings. Compared with the other three models, the BPS model had lower internal fixation stress among loading conditions, and the CBT screw internal fixation had the highest stress among loads. CONCLUSIONS: The BPS model provided the best biomechanical stability for OLIF. The SA model was relatively less stable. The UPS-CTFS group had reduced ROM in the fusion segments, but the stresses on the internal fixation and CAGE were relatively higher in the than in the BPS group; the CBT group had a lower flexion and extension ROM and higher rotation and lateral flexion ROM than the BPS group. The stability of the CBT group was poorer than that of the BPS and LPS-CTFS groups. The CAGE and internal fixation stress was greater in the CBT group.