Cargando…

A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry

BACKGROUND: To evaluate Inferior vena cava (IVC) filter retrieval practices over a 9-year period at an academic hospital with a prospectively maintained IVC filter registry. METHOD: An IVC filter registry was maintained prospectively within our institution. We reviewed cases between August 2011 and...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheehan, Mark, Coppin, Kristopher, O’Brien, Cormac, McGrath, Andrew, Given, Mark, Keeling, Aoife, Lee, Michael J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8898204/
https://www.ncbi.nlm.nih.gov/pubmed/35247104
http://dx.doi.org/10.1186/s42155-022-00291-5
_version_ 1784663595661918208
author Sheehan, Mark
Coppin, Kristopher
O’Brien, Cormac
McGrath, Andrew
Given, Mark
Keeling, Aoife
Lee, Michael J
author_facet Sheehan, Mark
Coppin, Kristopher
O’Brien, Cormac
McGrath, Andrew
Given, Mark
Keeling, Aoife
Lee, Michael J
author_sort Sheehan, Mark
collection PubMed
description BACKGROUND: To evaluate Inferior vena cava (IVC) filter retrieval practices over a 9-year period at an academic hospital with a prospectively maintained IVC filter registry. METHOD: An IVC filter registry was maintained prospectively within our institution. We reviewed cases between August 2011 and June 2020, following filter status, retrieval plans, and eventual retrieval date. The validity of the database was cross referenced with a Picture Archiving and Communication System and patient records. RESULTS: Three hundred forty-three patients had IVC filters inserted. Three filter types were used, Celect (Cook Medical) in 189, Gunther Tulip (GT) (Cook Medical) in 65, ALN (ALN) in 89. 196 (57%) filters were retrieved, 108 (31.5%) were made permanent, 36 (10.5%) died before retrieval, and 3 (1%) were yet to be retrieved. Retrieval rates were 92.5% overall (86% for GT, 93% for Celect and 94.5% for ALN). The mean dwell time for successful retrieval was 59 days with the majority of insertions (85%) removed in under 100 days. Failed initial retrieval occurred in 23 patients, 10 (43%) were retrieved at second attempt, 13/23 filters remained in-situ and were deemed permanent. CONCLUSION: The removal of IVC filters, when indication for insertion has past, is no longer the sole responsibility of the referring physician but also the responsibility of the Interventionalist. Our retrieval rates of 92.5% of eligible IVC filters highlights the value of maintaining a prospective IVC filter registry.
format Online
Article
Text
id pubmed-8898204
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-88982042022-03-08 A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry Sheehan, Mark Coppin, Kristopher O’Brien, Cormac McGrath, Andrew Given, Mark Keeling, Aoife Lee, Michael J CVIR Endovasc Original Article BACKGROUND: To evaluate Inferior vena cava (IVC) filter retrieval practices over a 9-year period at an academic hospital with a prospectively maintained IVC filter registry. METHOD: An IVC filter registry was maintained prospectively within our institution. We reviewed cases between August 2011 and June 2020, following filter status, retrieval plans, and eventual retrieval date. The validity of the database was cross referenced with a Picture Archiving and Communication System and patient records. RESULTS: Three hundred forty-three patients had IVC filters inserted. Three filter types were used, Celect (Cook Medical) in 189, Gunther Tulip (GT) (Cook Medical) in 65, ALN (ALN) in 89. 196 (57%) filters were retrieved, 108 (31.5%) were made permanent, 36 (10.5%) died before retrieval, and 3 (1%) were yet to be retrieved. Retrieval rates were 92.5% overall (86% for GT, 93% for Celect and 94.5% for ALN). The mean dwell time for successful retrieval was 59 days with the majority of insertions (85%) removed in under 100 days. Failed initial retrieval occurred in 23 patients, 10 (43%) were retrieved at second attempt, 13/23 filters remained in-situ and were deemed permanent. CONCLUSION: The removal of IVC filters, when indication for insertion has past, is no longer the sole responsibility of the referring physician but also the responsibility of the Interventionalist. Our retrieval rates of 92.5% of eligible IVC filters highlights the value of maintaining a prospective IVC filter registry. Springer International Publishing 2022-03-05 /pmc/articles/PMC8898204/ /pubmed/35247104 http://dx.doi.org/10.1186/s42155-022-00291-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Sheehan, Mark
Coppin, Kristopher
O’Brien, Cormac
McGrath, Andrew
Given, Mark
Keeling, Aoife
Lee, Michael J
A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry
title A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry
title_full A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry
title_fullStr A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry
title_full_unstemmed A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry
title_short A single center 9-year experience in IVC filter retrieval - the importance of an IVC filter registry
title_sort single center 9-year experience in ivc filter retrieval - the importance of an ivc filter registry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8898204/
https://www.ncbi.nlm.nih.gov/pubmed/35247104
http://dx.doi.org/10.1186/s42155-022-00291-5
work_keys_str_mv AT sheehanmark asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT coppinkristopher asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT obriencormac asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT mcgrathandrew asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT givenmark asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT keelingaoife asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT leemichaelj asinglecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT sheehanmark singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT coppinkristopher singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT obriencormac singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT mcgrathandrew singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT givenmark singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT keelingaoife singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry
AT leemichaelj singlecenter9yearexperienceinivcfilterretrievaltheimportanceofanivcfilterregistry