Cargando…
The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes
The outbreak of COVID-19 and the spread of infectious pathogens through bioaerosols have once again aroused widespread concern worldwide. Isolation ward is an important place to prevent the spread of infectious bioaerosols. However, infection of health care workers (HCWs) in the isolation ward often...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Southwest Jiatong University. Publishing services by Elsevier B.V. on behalf of KeAi Communication Co. Ltd.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8898349/ http://dx.doi.org/10.1016/j.enbenv.2022.03.002 |
_version_ | 1784663624500903936 |
---|---|
author | Liu, Zhijian Wang, Tianci Wang, Yongxin Liu, Haiyang Cao, Guoqing Tang, Song |
author_facet | Liu, Zhijian Wang, Tianci Wang, Yongxin Liu, Haiyang Cao, Guoqing Tang, Song |
author_sort | Liu, Zhijian |
collection | PubMed |
description | The outbreak of COVID-19 and the spread of infectious pathogens through bioaerosols have once again aroused widespread concern worldwide. Isolation ward is an important place to prevent the spread of infectious bioaerosols. However, infection of health care workers (HCWs) in the isolation ward often occurs, so it is urgent to carry out relevant research to reduce the cross-infection between HCWs and patients. In this paper, the temporal and spatial distribution characteristics of bioaerosols under three mixed ventilation modes in a single ward were studied, namely, upper supply side return air of Case 1 and side supply and side return ventilation are Case 2 and Case 3 respectively. The results show that the removal efficiency of bioaerosol in the ventilation mode of Case 3, in which directional airflow is formed from the air supply inlet to the release source and then to the exhaust outlet, is 46.6% and 67.7% higher than that of Case 1 and Case 2, respectively. In addition, ventilation methods based on mixed theory do not guarantee good air quality in the breathing zone (1.3 m to 1.7 m) of HCWs, which may increase the inhalation risk for HCWs. It is hoped that our results can provide some useful suggestions for optimizing the airflow layout of the isolation ward, reducing the risk of cross-infection, and virus elimination. |
format | Online Article Text |
id | pubmed-8898349 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Southwest Jiatong University. Publishing services by Elsevier B.V. on behalf of KeAi Communication Co. Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88983492022-03-07 The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes Liu, Zhijian Wang, Tianci Wang, Yongxin Liu, Haiyang Cao, Guoqing Tang, Song Energy and Built Environment Article The outbreak of COVID-19 and the spread of infectious pathogens through bioaerosols have once again aroused widespread concern worldwide. Isolation ward is an important place to prevent the spread of infectious bioaerosols. However, infection of health care workers (HCWs) in the isolation ward often occurs, so it is urgent to carry out relevant research to reduce the cross-infection between HCWs and patients. In this paper, the temporal and spatial distribution characteristics of bioaerosols under three mixed ventilation modes in a single ward were studied, namely, upper supply side return air of Case 1 and side supply and side return ventilation are Case 2 and Case 3 respectively. The results show that the removal efficiency of bioaerosol in the ventilation mode of Case 3, in which directional airflow is formed from the air supply inlet to the release source and then to the exhaust outlet, is 46.6% and 67.7% higher than that of Case 1 and Case 2, respectively. In addition, ventilation methods based on mixed theory do not guarantee good air quality in the breathing zone (1.3 m to 1.7 m) of HCWs, which may increase the inhalation risk for HCWs. It is hoped that our results can provide some useful suggestions for optimizing the airflow layout of the isolation ward, reducing the risk of cross-infection, and virus elimination. Southwest Jiatong University. Publishing services by Elsevier B.V. on behalf of KeAi Communication Co. Ltd. 2023-08 2022-03-06 /pmc/articles/PMC8898349/ http://dx.doi.org/10.1016/j.enbenv.2022.03.002 Text en Copyright © 2022 Southwest Jiatong University. Publishing services by Elsevier B.V. on behalf of KeAi Communication Co. Ltd. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Liu, Zhijian Wang, Tianci Wang, Yongxin Liu, Haiyang Cao, Guoqing Tang, Song The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
title | The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
title_full | The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
title_fullStr | The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
title_full_unstemmed | The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
title_short | The influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
title_sort | influence of air supply inlet location on the spatial-temporal distribution of bioaerosol in isolation ward under three mixed ventilation modes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8898349/ http://dx.doi.org/10.1016/j.enbenv.2022.03.002 |
work_keys_str_mv | AT liuzhijian theinfluenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT wangtianci theinfluenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT wangyongxin theinfluenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT liuhaiyang theinfluenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT caoguoqing theinfluenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT tangsong theinfluenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT liuzhijian influenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT wangtianci influenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT wangyongxin influenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT liuhaiyang influenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT caoguoqing influenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes AT tangsong influenceofairsupplyinletlocationonthespatialtemporaldistributionofbioaerosolinisolationwardunderthreemixedventilationmodes |