Cargando…
Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial
Chest auscultation is the first procedure performed to detect endotracheal tube malpositioning but conventional stethoscopes do not conform to the personal protective equipment (PPE) protocol during the COVID-19 pandemic. This double-blinded randomized controlled trial evaluated the feasibility of u...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8899469/ https://www.ncbi.nlm.nih.gov/pubmed/35265648 http://dx.doi.org/10.3389/fmed.2022.851395 |
_version_ | 1784663923479281664 |
---|---|
author | Wei, Tzu-Jung Hsiung, Ping-Yan Liu, Jen-Hao Lin, Tzu-Chun Kuo, Fang-Tzu Wu, Chun-Yu |
author_facet | Wei, Tzu-Jung Hsiung, Ping-Yan Liu, Jen-Hao Lin, Tzu-Chun Kuo, Fang-Tzu Wu, Chun-Yu |
author_sort | Wei, Tzu-Jung |
collection | PubMed |
description | Chest auscultation is the first procedure performed to detect endotracheal tube malpositioning but conventional stethoscopes do not conform to the personal protective equipment (PPE) protocol during the COVID-19 pandemic. This double-blinded randomized controlled trial evaluated the feasibility of using ear-contactless electronic stethoscope to identify endobronchial blocker established selective lung ventilation, simulating endobronchial intubation during thoracic surgery with full PPE. Conventional and electronic auscultation was performed without and with full PPE, respectively, of 50 patients with selective lung ventilation. The rates of correct ventilation status detection were 86 and 88% in the conventional and electronic auscultation groups (p = 1.00). Electronic auscultation revealed a positive predictive value of 87% (95% CI 77 to 93%), and a negative predictive value of 91% (95% CI 58 to 99%), comparable to the results for conventional auscultation. For detection of the true unilateral lung ventilation, the F1 score and the phi were 0.904 and 0.654, respectively for conventional auscultation; were 0.919 and 0.706, respectively for electronic auscultation. Furthermore, the user experience questionnaire revealed that the majority of participant anesthesiologists (90.5%) rated the audio quality of electronic lung sounds as comparable or superior to that of conventional acoustic lung sounds. In conclusion, electronic auscultation assessments of ventilation status as examined during thoracic surgery in full PPE were comparable in accuracy to corresponding conventional auscultation assessments made without PPE. Users reported satisfactory experience with the electronic stethoscope. |
format | Online Article Text |
id | pubmed-8899469 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88994692022-03-08 Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial Wei, Tzu-Jung Hsiung, Ping-Yan Liu, Jen-Hao Lin, Tzu-Chun Kuo, Fang-Tzu Wu, Chun-Yu Front Med (Lausanne) Medicine Chest auscultation is the first procedure performed to detect endotracheal tube malpositioning but conventional stethoscopes do not conform to the personal protective equipment (PPE) protocol during the COVID-19 pandemic. This double-blinded randomized controlled trial evaluated the feasibility of using ear-contactless electronic stethoscope to identify endobronchial blocker established selective lung ventilation, simulating endobronchial intubation during thoracic surgery with full PPE. Conventional and electronic auscultation was performed without and with full PPE, respectively, of 50 patients with selective lung ventilation. The rates of correct ventilation status detection were 86 and 88% in the conventional and electronic auscultation groups (p = 1.00). Electronic auscultation revealed a positive predictive value of 87% (95% CI 77 to 93%), and a negative predictive value of 91% (95% CI 58 to 99%), comparable to the results for conventional auscultation. For detection of the true unilateral lung ventilation, the F1 score and the phi were 0.904 and 0.654, respectively for conventional auscultation; were 0.919 and 0.706, respectively for electronic auscultation. Furthermore, the user experience questionnaire revealed that the majority of participant anesthesiologists (90.5%) rated the audio quality of electronic lung sounds as comparable or superior to that of conventional acoustic lung sounds. In conclusion, electronic auscultation assessments of ventilation status as examined during thoracic surgery in full PPE were comparable in accuracy to corresponding conventional auscultation assessments made without PPE. Users reported satisfactory experience with the electronic stethoscope. Frontiers Media S.A. 2022-02-21 /pmc/articles/PMC8899469/ /pubmed/35265648 http://dx.doi.org/10.3389/fmed.2022.851395 Text en Copyright © 2022 Wei, Hsiung, Liu, Lin, Kuo and Wu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Wei, Tzu-Jung Hsiung, Ping-Yan Liu, Jen-Hao Lin, Tzu-Chun Kuo, Fang-Tzu Wu, Chun-Yu Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial |
title | Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial |
title_full | Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial |
title_fullStr | Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial |
title_full_unstemmed | Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial |
title_short | Use of Electronic Auscultation in Full Personal Protective Equipment to Detect Ventilation Status in Selective Lung Ventilation: A Randomized Controlled Trial |
title_sort | use of electronic auscultation in full personal protective equipment to detect ventilation status in selective lung ventilation: a randomized controlled trial |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8899469/ https://www.ncbi.nlm.nih.gov/pubmed/35265648 http://dx.doi.org/10.3389/fmed.2022.851395 |
work_keys_str_mv | AT weitzujung useofelectronicauscultationinfullpersonalprotectiveequipmenttodetectventilationstatusinselectivelungventilationarandomizedcontrolledtrial AT hsiungpingyan useofelectronicauscultationinfullpersonalprotectiveequipmenttodetectventilationstatusinselectivelungventilationarandomizedcontrolledtrial AT liujenhao useofelectronicauscultationinfullpersonalprotectiveequipmenttodetectventilationstatusinselectivelungventilationarandomizedcontrolledtrial AT lintzuchun useofelectronicauscultationinfullpersonalprotectiveequipmenttodetectventilationstatusinselectivelungventilationarandomizedcontrolledtrial AT kuofangtzu useofelectronicauscultationinfullpersonalprotectiveequipmenttodetectventilationstatusinselectivelungventilationarandomizedcontrolledtrial AT wuchunyu useofelectronicauscultationinfullpersonalprotectiveequipmenttodetectventilationstatusinselectivelungventilationarandomizedcontrolledtrial |