Cargando…
Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis
The treatment of fractures of the distal tibia can be problematic due to the insubstantial soft-tissue covering this part of the anatomy. This study investigates a novel strategy for minimally invasive plate osteosynthesis of distal tibia fractures called bionic lightweight design plating. Following...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901108/ https://www.ncbi.nlm.nih.gov/pubmed/35265599 http://dx.doi.org/10.3389/fbioe.2022.820921 |
_version_ | 1784664279996170240 |
---|---|
author | Wang, Mian Deng, Yuping Xie, Pusheng Tan, Jinchuan Yang, Yang Ouyang, Hanbin Zhao, Dongliang Huang, Gang Huang, Wenhua |
author_facet | Wang, Mian Deng, Yuping Xie, Pusheng Tan, Jinchuan Yang, Yang Ouyang, Hanbin Zhao, Dongliang Huang, Gang Huang, Wenhua |
author_sort | Wang, Mian |
collection | PubMed |
description | The treatment of fractures of the distal tibia can be problematic due to the insubstantial soft-tissue covering this part of the anatomy. This study investigates a novel strategy for minimally invasive plate osteosynthesis of distal tibia fractures called bionic lightweight design plating. Following the structure of the animal trabecular bone, we utilized topological mathematical methods to redesign the material layout of the internal fixation device to fulfill the desired lightweight design within given boundary conditions. The results showed that this method can maintain the same stability of the construct as the original plate after a reduction in the original volume by 30%, and the differences in strain energy of plates and maximum node displacement of constructs between the constructs [RP construct vs. LP construct] were not statistically significant (p > 0.05). In the safety assessment of the constructs, the peak stress of plates between constructs was found to not be statistically significantly different under a doubled physiological load (p > 0.05). The average stress of the plates’ elements exceeding the allowable stress was analyzed, and no statistically significant differences were found between the two constructs under axial compression stress conditions (p > 0.05). The average stress of the plates’ elements in the redesigned plating construct under torsional stress conditions was 3.08% less than that of the locked plating construct (p < 0.05). Under the double physiological load condition, 89% of the elements of the plate in the redesigned plating construct and 85% of the elements of the plate in the locked plating construct were lower than the maximum safe stress of the plate, which was 410 MPa (secondary allowable stresses). That reminds us the topology optimization offer a possible way to improve the capacity of soft tissue protection while ensuring the safety of the RP construct by reducing the volume of the implants. |
format | Online Article Text |
id | pubmed-8901108 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-89011082022-03-08 Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis Wang, Mian Deng, Yuping Xie, Pusheng Tan, Jinchuan Yang, Yang Ouyang, Hanbin Zhao, Dongliang Huang, Gang Huang, Wenhua Front Bioeng Biotechnol Bioengineering and Biotechnology The treatment of fractures of the distal tibia can be problematic due to the insubstantial soft-tissue covering this part of the anatomy. This study investigates a novel strategy for minimally invasive plate osteosynthesis of distal tibia fractures called bionic lightweight design plating. Following the structure of the animal trabecular bone, we utilized topological mathematical methods to redesign the material layout of the internal fixation device to fulfill the desired lightweight design within given boundary conditions. The results showed that this method can maintain the same stability of the construct as the original plate after a reduction in the original volume by 30%, and the differences in strain energy of plates and maximum node displacement of constructs between the constructs [RP construct vs. LP construct] were not statistically significant (p > 0.05). In the safety assessment of the constructs, the peak stress of plates between constructs was found to not be statistically significantly different under a doubled physiological load (p > 0.05). The average stress of the plates’ elements exceeding the allowable stress was analyzed, and no statistically significant differences were found between the two constructs under axial compression stress conditions (p > 0.05). The average stress of the plates’ elements in the redesigned plating construct under torsional stress conditions was 3.08% less than that of the locked plating construct (p < 0.05). Under the double physiological load condition, 89% of the elements of the plate in the redesigned plating construct and 85% of the elements of the plate in the locked plating construct were lower than the maximum safe stress of the plate, which was 410 MPa (secondary allowable stresses). That reminds us the topology optimization offer a possible way to improve the capacity of soft tissue protection while ensuring the safety of the RP construct by reducing the volume of the implants. Frontiers Media S.A. 2022-02-21 /pmc/articles/PMC8901108/ /pubmed/35265599 http://dx.doi.org/10.3389/fbioe.2022.820921 Text en Copyright © 2022 Wang, Deng, Xie, Tan, Yang, Ouyang, Zhao, Huang and Huang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Wang, Mian Deng, Yuping Xie, Pusheng Tan, Jinchuan Yang, Yang Ouyang, Hanbin Zhao, Dongliang Huang, Gang Huang, Wenhua Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis |
title | Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis |
title_full | Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis |
title_fullStr | Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis |
title_full_unstemmed | Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis |
title_short | Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis |
title_sort | optimal design and biomechanical analysis of a biomimetic lightweight design plate for distal tibial fractures: a finite element analysis |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901108/ https://www.ncbi.nlm.nih.gov/pubmed/35265599 http://dx.doi.org/10.3389/fbioe.2022.820921 |
work_keys_str_mv | AT wangmian optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT dengyuping optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT xiepusheng optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT tanjinchuan optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT yangyang optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT ouyanghanbin optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT zhaodongliang optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT huanggang optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis AT huangwenhua optimaldesignandbiomechanicalanalysisofabiomimeticlightweightdesignplatefordistaltibialfracturesafiniteelementanalysis |