Cargando…
Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction
The prefiltered image was imported into the local higher-order singular value decomposition (HOSVD) denoising algorithm (GL-HOSVD)-optimized diffusion-weighted imaging (DWI) image, which was compared with the deviation correction nonlocal mean (NL mean) and low-level edge algorithm (LR + edge). Rega...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901298/ https://www.ncbi.nlm.nih.gov/pubmed/35291425 http://dx.doi.org/10.1155/2022/6270700 |
_version_ | 1784664333589938176 |
---|---|
author | Sheng, Hui Wang, Xueling Jiang, Meiping Zhang, Zhongsheng |
author_facet | Sheng, Hui Wang, Xueling Jiang, Meiping Zhang, Zhongsheng |
author_sort | Sheng, Hui |
collection | PubMed |
description | The prefiltered image was imported into the local higher-order singular value decomposition (HOSVD) denoising algorithm (GL-HOSVD)-optimized diffusion-weighted imaging (DWI) image, which was compared with the deviation correction nonlocal mean (NL mean) and low-level edge algorithm (LR + edge). Regarding the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), sensitivity, specificity, accuracy, and consistency, the application effect of the GL-HOSVD algorithm in DWI was investigated, and its adoption effect in the examination of ischemic penumbra (IP) of early acute cerebral infarction (ACI) patients was evaluated. A total of 210 patients with ACI were selected as the research subjects, who were randomly rolled into two groups. Those who were checked by conventional DWI were set as the control group, and those who used DWI based on the GL-HOSVD denoising algorithm were set as the observation group, with 105 people in each. Positron emission tomography (PET) test results were set as the gold standard to evaluate the application value of the two examination methods. It was found that under different noise levels, the peak signal-to-noise ratio (PSNR) of the GL-HOSVD algorithm and the root mean square error (RMSE) of the FA parameter were better than those of the nonlocal means (NL-means) of deviation correction and low-rank edge algorithm (LR + edge). The sensitivity, specificity, accuracy, and consistency (8.76%, 81.25%, 87.62%, and 0.52) of the observation group were higher than those of the control group (57.78%, 53.33%, 57.14%, and 0.35) (P < 0.05). Moreover, the apparent diffusion coefficient (ADC) of the DWI images of the observation group was basically consistent with that of the PET images, while the control group had a poor display effect and low definition. In summary, under different noise levels, the GL-HOSVD algorithm had a good denoising effect and greatly reduced fringe artifacts. DWI after denoising had high sensitivity, specificity, accuracy, and consistency in the detection of IP, which was worthy of clinical application and promotion. |
format | Online Article Text |
id | pubmed-8901298 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-89012982022-03-14 Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction Sheng, Hui Wang, Xueling Jiang, Meiping Zhang, Zhongsheng Contrast Media Mol Imaging Research Article The prefiltered image was imported into the local higher-order singular value decomposition (HOSVD) denoising algorithm (GL-HOSVD)-optimized diffusion-weighted imaging (DWI) image, which was compared with the deviation correction nonlocal mean (NL mean) and low-level edge algorithm (LR + edge). Regarding the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), sensitivity, specificity, accuracy, and consistency, the application effect of the GL-HOSVD algorithm in DWI was investigated, and its adoption effect in the examination of ischemic penumbra (IP) of early acute cerebral infarction (ACI) patients was evaluated. A total of 210 patients with ACI were selected as the research subjects, who were randomly rolled into two groups. Those who were checked by conventional DWI were set as the control group, and those who used DWI based on the GL-HOSVD denoising algorithm were set as the observation group, with 105 people in each. Positron emission tomography (PET) test results were set as the gold standard to evaluate the application value of the two examination methods. It was found that under different noise levels, the peak signal-to-noise ratio (PSNR) of the GL-HOSVD algorithm and the root mean square error (RMSE) of the FA parameter were better than those of the nonlocal means (NL-means) of deviation correction and low-rank edge algorithm (LR + edge). The sensitivity, specificity, accuracy, and consistency (8.76%, 81.25%, 87.62%, and 0.52) of the observation group were higher than those of the control group (57.78%, 53.33%, 57.14%, and 0.35) (P < 0.05). Moreover, the apparent diffusion coefficient (ADC) of the DWI images of the observation group was basically consistent with that of the PET images, while the control group had a poor display effect and low definition. In summary, under different noise levels, the GL-HOSVD algorithm had a good denoising effect and greatly reduced fringe artifacts. DWI after denoising had high sensitivity, specificity, accuracy, and consistency in the detection of IP, which was worthy of clinical application and promotion. Hindawi 2022-02-28 /pmc/articles/PMC8901298/ /pubmed/35291425 http://dx.doi.org/10.1155/2022/6270700 Text en Copyright © 2022 Hui Sheng et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Sheng, Hui Wang, Xueling Jiang, Meiping Zhang, Zhongsheng Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction |
title | Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction |
title_full | Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction |
title_fullStr | Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction |
title_full_unstemmed | Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction |
title_short | Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction |
title_sort | deep learning-based diffusion-weighted magnetic resonance imaging in the diagnosis of ischemic penumbra in early cerebral infarction |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901298/ https://www.ncbi.nlm.nih.gov/pubmed/35291425 http://dx.doi.org/10.1155/2022/6270700 |
work_keys_str_mv | AT shenghui deeplearningbaseddiffusionweightedmagneticresonanceimaginginthediagnosisofischemicpenumbrainearlycerebralinfarction AT wangxueling deeplearningbaseddiffusionweightedmagneticresonanceimaginginthediagnosisofischemicpenumbrainearlycerebralinfarction AT jiangmeiping deeplearningbaseddiffusionweightedmagneticresonanceimaginginthediagnosisofischemicpenumbrainearlycerebralinfarction AT zhangzhongsheng deeplearningbaseddiffusionweightedmagneticresonanceimaginginthediagnosisofischemicpenumbrainearlycerebralinfarction |